These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

146 related articles for article (PubMed ID: 31993849)

  • 1. Phentroimidazole Based Fluorescence "Turn on" Sensor for Highly Sensitive Detection of Zn
    Kutluca Alici M
    J Fluoresc; 2020 Mar; 30(2):269-273. PubMed ID: 31993849
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A highly potential acyclic Schiff base fluorescent turn on sensor for Zn
    Jayaraj A; Gayathri MS; Sivaraman G; P CAS
    J Photochem Photobiol B; 2022 Jan; 226():112371. PubMed ID: 34906923
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A novel Schiff base: Synthesis, structural characterisation and comparative sensor studies for metal ion detections.
    Köse M; Purtas S; Güngör SA; Ceyhan G; Akgün E; McKee V
    Spectrochim Acta A Mol Biomol Spectrosc; 2015 Feb; 136 Pt C():1388-94. PubMed ID: 25459697
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Chromo/Fluorogenic Detection of Co(2+), Hg(2+) and Cu(2+) by the Simple Schiff Base Sensor.
    Saleem M; Khang CH; Kim MH; Lee KH
    J Fluoresc; 2016 Jan; 26(1):11-22. PubMed ID: 26585349
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A Selective Turn off Fluorescence Sensor Based on Propranolol-SDS Assemblies for Fe
    Gujar V; Sangale V; Ottoor D
    J Fluoresc; 2019 Jan; 29(1):91-100. PubMed ID: 30361859
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The salen based chemosensors for highly selective recognition of Zn
    Zhu W; Du L; Li W; Zuo J; Shan J
    Spectrochim Acta A Mol Biomol Spectrosc; 2018 Oct; 203():501-509. PubMed ID: 29902756
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A novel Schiff-base as a Cu(II) ion fluorescent sensor in aqueous solution.
    Gündüz ZY; Gündüz C; Özpınar C; Urucu OA
    Spectrochim Acta A Mol Biomol Spectrosc; 2015 Feb; 136 Pt C():1679-83. PubMed ID: 25459732
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The amidine based colorimetric sensor for Fe(3+), Fe (2+), and Cu (2+) in aqueous medium.
    Nandre J; Patil S; Patil P; Sahoo S; Redshaw C; Mahulikar P; Patil U
    J Fluoresc; 2014 Nov; 24(6):1563-70. PubMed ID: 25209201
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Pyrene Substituted Phthalonitrile Derivative As a Fluorescent Sensor For Detection of Fe
    Alraqa SY; Kaya EN; Taşci N; Erbahar D; Durmuş M
    J Fluoresc; 2022 Sep; 32(5):1801-1813. PubMed ID: 35704139
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A switch-off fluorescence probe towards Pb(II) and cu(II) ions based on a calix[4]pyrrole bearing amino-quinoline group.
    Bhatt KD; Shah HD; Panchal M
    Luminescence; 2017 Dec; 32(8):1398-1404. PubMed ID: 28590050
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Novel Benzothiazole-Based Highly Selective Ratiometric Fluorescent Turn-On Sensors for Zn
    Pothulapadu CAS; Jayaraj A; N S; Priyanka RN; Sivaraman G
    ACS Omega; 2021 Sep; 6(38):24473-24483. PubMed ID: 34604629
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A New Spiropyran-Based Sensor for Colorimetric and Fluorescent Detection of Divalent Cu
    Wang Y; Xu Z; Dai X; Li H; Yu S; Meng W
    J Fluoresc; 2019 May; 29(3):569-575. PubMed ID: 30919128
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A new fluorescent and electrochemical Zn2+ ion sensor based on Schiff base derived from benzil and L-tryptophan.
    Dutta K; Deka RC; Das DK
    Spectrochim Acta A Mol Biomol Spectrosc; 2014 Apr; 124():124-9. PubMed ID: 24468984
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Highly fluorescent hematoporphyrin modified graphene oxide for selective detection of copper ions in aqueous solutions.
    Awad FS; AbouZied KM; Bakry AM; Abou El-Maaty WM; El-Wakil AM; El-Shall MS
    Anal Chim Acta; 2020 Dec; 1140():111-121. PubMed ID: 33218473
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A highly selective and sensitive fluorescent sensor for the rapid detection of Hg²⁺ based on phenylamine-oligothiophene derivative.
    Niu Q; Wu X; Zhang S; Li T; Cui Y; Li X
    Spectrochim Acta A Mol Biomol Spectrosc; 2016 Jan; 153():143-6. PubMed ID: 26298681
    [TBL] [Abstract][Full Text] [Related]  

  • 16. 3-Aminopyridine Salicylidene: A Sensitive and Selective Chemosensor for the Detection of Cu(II), Al(III), and Fe(III) with Application to Real Samples.
    Hijji YM; Rajan R; Shraim AM
    Int J Mol Sci; 2022 Oct; 23(21):. PubMed ID: 36361899
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A New Schiff Base Based Fluorescent Sensor for Al(III) Based on 2-Hydroxyacetophenone and o-Phenylenediamine.
    Bharali B; Talukdar H; Phukan P; Das DK
    J Fluoresc; 2020 Jul; 30(4):751-757. PubMed ID: 32410084
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Hg
    Tekuri V; Sahoo SK; Trivedi DR
    Spectrochim Acta A Mol Biomol Spectrosc; 2019 Jul; 218():19-26. PubMed ID: 30952027
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Fluorescent Polyamide-Based Rhodamine Hydrazide Moieties with Oxethyl as Spacer for Detection of Cr(3+), Fe(3+), and Hg(2+) Ions in Water.
    Geng TM; Wang X; Jiang H; Song W; Ni RF; Chen J; Wang Y
    J Fluoresc; 2016 May; 26(3):977-85. PubMed ID: 26979056
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Differentially selective chemosensor with fluorescence off-on responses on Cu(2+) and Zn(2+) ions in aqueous media and applications in pyrophosphate sensing, live cell imaging, and cytotoxicity.
    Anbu S; Ravishankaran R; Guedes da Silva MF; Karande AA; Pombeiro AJ
    Inorg Chem; 2014 Jul; 53(13):6655-64. PubMed ID: 24999857
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.