BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

333 related articles for article (PubMed ID: 31996931)

  • 1. Malrotation of the fixed-bearing posterior stabilized total knee prosthesis causes a postoperative rotational mismatch between the femur and tibia.
    Ueyama H; Minoda Y; Sugama R; Ohta Y; Yamamura K; Nakamura S; Takemura S; Nakamura H
    Knee Surg Sports Traumatol Arthrosc; 2020 Dec; 28(12):3810-3820. PubMed ID: 31996931
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Preoperative tibiofemoral rotational alignment is a risk factor for component rotational mismatch in total knee arthroplasty.
    Kawaguchi K; Inui H; Taketomi S; Yamagami R; Kono K; Sameshima S; Kage T; Tanaka S
    Knee; 2021 Mar; 29():448-456. PubMed ID: 33743260
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Component rotational alignment in unexplained painful primary total knee arthroplasty.
    Bell SW; Young P; Drury C; Smith J; Anthony I; Jones B; Blyth M; McLean A
    Knee; 2014 Jan; 21(1):272-7. PubMed ID: 23140906
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Mobile-bearing prosthesis suppresses the postoperative rotational mismatch and improves patient-reported outcome measurements better than fixed-bearing prosthesis: rotational analysis by 3D measurement in total knee arthroplasty.
    Ueyama H; Minoda Y; Sugama R; Ohta Y; Takemura S; Nakamura H
    Arch Orthop Trauma Surg; 2023 Nov; 143(11):6781-6790. PubMed ID: 37418005
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Prosthesis alignment affects axial rotation motion after total knee replacement: a prospective in vivo study combining computed tomography and fluoroscopic evaluations.
    Harman MK; Banks SA; Kirschner S; Lützner J
    BMC Musculoskelet Disord; 2012 Oct; 13():206. PubMed ID: 23088451
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Rotational alignment of the tibial component affects the kinematic rotation of a weight-bearing knee after total knee arthroplasty.
    Nakahara H; Okazaki K; Hamai S; Kawahara S; Higaki H; Mizu-uchi H; Iwamoto Y
    Knee; 2015 Jun; 22(3):201-5. PubMed ID: 25800285
    [TBL] [Abstract][Full Text] [Related]  

  • 7. What Factors Are Associated With Femoral Component Internal Rotation in TKA Using the Gap Balancing Technique?
    Lee SY; Lim HC; Jang KM; Bae JH
    Clin Orthop Relat Res; 2017 Aug; 475(8):1999-2010. PubMed ID: 28337656
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Internal rotation of femoral component affects functional activities after TKA--survey with the 2011 Knee Society Score.
    Kawahara S; Okazaki K; Matsuda S; Nakahara H; Okamoto S; Iwamoto Y
    J Arthroplasty; 2014 Dec; 29(12):2319-23. PubMed ID: 24388616
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Combined femoral and tibial component total knee arthroplasty device rotation measurement is reliable and predicts clinical outcome.
    Hernández-Hermoso JA; Nescolarde L; Yañez-Siller F; Calle-García J; Garcia-Perdomo D; Pérez-Andres R
    J Orthop Traumatol; 2023 Aug; 24(1):40. PubMed ID: 37535276
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effect of Rotational Component Alignment on Clinical Outcome 5 to 7 Years After TKA With the Columbus Knee System.
    Thielemann FW; Konstantinids L; Herget GW; Knothe D; Helwig P; Sudkamp NP; Hauschild O
    Orthopedics; 2016 May; 39(3 Suppl):S50-5. PubMed ID: 27219729
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Rotational mismatch between femoral and tibial components should be avoided in JOURNEY II bi-cruciate stabilized total knee arthroplasty.
    Fujita M; Matsumoto T; Nakano N; Ishida K; Kuroda Y; Maeda T; Hayashi S; Kuroda R
    Knee; 2022 Oct; 38():69-75. PubMed ID: 35930895
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Internal femoral component malrotation in TKA significantly alters tibiofemoral kinematics.
    Heyse TJ; El-Zayat BF; De Corte R; Chevalier Y; Fuchs-Winkelmann S; Labey L
    Knee Surg Sports Traumatol Arthrosc; 2018 Jun; 26(6):1767-1775. PubMed ID: 29128876
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Does Component Alignment Affect Patient Reported Outcomes following Bicruciate Retaining Total Knee Arthroplasty? An In Vivo Three-Dimensional Analysis.
    Peng Y; Arauz P; An S; Limmahakhun S; Klemt C; Kwon YM
    J Knee Surg; 2020 Aug; 33(8):798-803. PubMed ID: 31064018
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Femoral matched tibia component rotation has little effect on the tibial torsion after total knee arthroplasty.
    Bae JH; Lee JW; Kim SH; Kim SG; Jeon YS; Choi JS
    Knee Surg Sports Traumatol Arthrosc; 2022 Feb; 30(2):698-704. PubMed ID: 33449142
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Tibial internal rotation negatively affects clinical outcomes in total knee arthroplasty: a systematic review.
    Panni AS; Ascione F; Rossini M; Braile A; Corona K; Vasso M; Hirschmann MT
    Knee Surg Sports Traumatol Arthrosc; 2018 Jun; 26(6):1636-1644. PubMed ID: 29247357
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Partially loaded plain radiographic measurement to evaluate rotational alignment in total knee arthroplasty.
    Pedraza W; Beckmann J; Mayer C; Mauch F; Huth J; Best R
    Int Orthop; 2016 Dec; 40(12):2519-2526. PubMed ID: 27447464
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Rotational landmarks and total knee arthroplasty in osteoarthritic knees].
    Sun T; Lv H; Hong N
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2007 Mar; 21(3):226-30. PubMed ID: 17419197
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Rotational positioning of the tibial tray in total knee arthroplasty: a CT evaluation.
    Berhouet J; Beaufils P; Boisrenoult P; Frasca D; Pujol N
    Orthop Traumatol Surg Res; 2011 Nov; 97(7):699-704. PubMed ID: 21993150
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Rotational alignment of the tibial component in total knee arthroplasty is better at the medial third of tibial tuberosity than at the medial border.
    Lützner J; Krummenauer F; Günther KP; Kirschner S
    BMC Musculoskelet Disord; 2010 Mar; 11():57. PubMed ID: 20338042
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [EFFECT OF MEDIAL 1/3 ANATOMICAL ORIENTATION OF TIBIAL TUBERCLE ON ROTATIONAL ALIGNMENT OF Gemini MK-II TIBIAL COMPONENTS IN TOTAL KNEE ARTHROPLASTY].
    Sun Z; Sun Y; Ren Z; Liu J; Wang L
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2015 Sep; 29(9):1062-6. PubMed ID: 26750000
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 17.