158 related articles for article (PubMed ID: 32003060)
1. Terminal ileum intubation is not associated with colonoscopy quality measures.
Leiman DA; Jawitz NG; Lin L; Wood RK; Gellad ZF
J Gastroenterol Hepatol; 2020 Sep; 35(9):1503-1508. PubMed ID: 32003060
[TBL] [Abstract][Full Text] [Related]
2. Ileal intubation is not associated with higher detection rate of right-sided conventional adenomas and serrated polyps compared to cecal intubation after adjustment for overall adenoma detection rate.
Buerger M; Kasper P; Allo G; Gillessen J; Schramm C
BMC Gastroenterol; 2019 Nov; 19(1):190. PubMed ID: 31730463
[TBL] [Abstract][Full Text] [Related]
3. Prevalence and variable detection of proximal colon serrated polyps during screening colonoscopy.
Kahi CJ; Hewett DG; Norton DL; Eckert GJ; Rex DK
Clin Gastroenterol Hepatol; 2011 Jan; 9(1):42-6. PubMed ID: 20888435
[TBL] [Abstract][Full Text] [Related]
4. Effect of time of day and specialty on polyp detection rates in Australia.
Zorron Cheng Tao Pu L; Lu K; Ovenden A; Rana K; Singh G; Krishnamurthi S; Edwards S; Wilson B; Nakamura M; Yamamura T; Ruszkiewicz A; Hirooka Y; Burt AD; Singh R
J Gastroenterol Hepatol; 2019 May; 34(5):899-906. PubMed ID: 30552716
[TBL] [Abstract][Full Text] [Related]
5. Colonoscopy Quality Assurance and Maintenance of Competency Among Pediatric Gastroenterology Staff Members: A Canadian Center Experience.
Alaifan M; Barker C
Cureus; 2022 Jun; 14(6):e26126. PubMed ID: 35875270
[TBL] [Abstract][Full Text] [Related]
6. Screening Colonoscopy Withdrawal Time Threshold for Adequate Proximal Serrated Polyp Detection Rate.
Patel VD; Thompson WK; Lapin BR; Goldstein JL; Yen EF
Dig Dis Sci; 2018 Nov; 63(11):3084-3090. PubMed ID: 29974376
[TBL] [Abstract][Full Text] [Related]
7. Routine ileal intubation in colonoscopy does not increase the polyp detection rate: a retrospective study.
Wang W; Chen K; Xu Y; Zhou Y; Chen P
Z Gastroenterol; 2020 Oct; 58(10):955-959. PubMed ID: 33036049
[TBL] [Abstract][Full Text] [Related]
8. Association of Adenoma and Proximal Sessile Serrated Polyp Detection Rates With Endoscopist Characteristics.
Sarvepalli S; Garber A; Rothberg MB; Mankaney G; McMichael J; Morris-Stiff G; Vargo JJ; Rizk MK; Burke CA
JAMA Surg; 2019 Jul; 154(7):627-635. PubMed ID: 30994911
[TBL] [Abstract][Full Text] [Related]
9. Quality of colonoscopy in an organised colorectal cancer screening programme with immunochemical faecal occult blood test: the EQuIPE study (Evaluating Quality Indicators of the Performance of Endoscopy).
Zorzi M; Senore C; Da Re F; Barca A; Bonelli LA; Cannizzaro R; Fasoli R; Di Furia L; Di Giulio E; Mantellini P; Naldoni C; Sassatelli R; Rex D; Hassan C; Zappa M;
Gut; 2015 Sep; 64(9):1389-96. PubMed ID: 25227521
[TBL] [Abstract][Full Text] [Related]
10. Serrated polyp detection rate during screening colonoscopy.
Liang J; Kalady MF; Appau K; Church J
Colorectal Dis; 2012 Nov; 14(11):1323-7. PubMed ID: 22390284
[TBL] [Abstract][Full Text] [Related]
11. Endoscopic detection of proximal serrated lesions and pathologic identification of sessile serrated adenomas/polyps vary on the basis of center.
Payne SR; Church TR; Wandell M; Rösch T; Osborn N; Snover D; Day RW; Ransohoff DF; Rex DK
Clin Gastroenterol Hepatol; 2014 Jul; 12(7):1119-26. PubMed ID: 24333512
[TBL] [Abstract][Full Text] [Related]
12. Impact of a quarterly report card on colonoscopy quality measures.
Kahi CJ; Ballard D; Shah AS; Mears R; Johnson CS
Gastrointest Endosc; 2013 Jun; 77(6):925-31. PubMed ID: 23472996
[TBL] [Abstract][Full Text] [Related]
13. Adenoma and sessile serrated polyp detection rates: variation by patient sex and colonic segment but not specialty of the endoscopist.
Sanaka MR; Gohel T; Podugu A; Kiran RP; Thota PN; Lopez R; Church JM; Burke CA
Dis Colon Rectum; 2014 Sep; 57(9):1113-9. PubMed ID: 25101608
[TBL] [Abstract][Full Text] [Related]
14. Should Assessment of Quality Indicator of Colonoscopy Be Varied Depending on the Colonoscopic Technique Level?
Choung BS; Kim SH; Yoo KB; Seo SY; Kim IH; Lee SO; Lee ST; Kim SW
Dig Dis Sci; 2016 Mar; 61(3):731-6. PubMed ID: 26576553
[TBL] [Abstract][Full Text] [Related]
15. Procedure Delays and Time of Day Are Not Associated With Reductions in Quality of Screening Colonoscopies.
Keswani RN; Gawron AJ; Cooper A; Liss DT
Clin Gastroenterol Hepatol; 2016 May; 14(5):723-8.e2. PubMed ID: 26538206
[TBL] [Abstract][Full Text] [Related]
16. High quality of screening colonoscopy in Austria is not dependent on endoscopist specialty or setting.
Kozbial K; Reinhart K; Heinze G; Zwatz C; Bannert C; Salzl P; Waldmann E; Britto-Arias M; Ferlitsch A; Trauner M; Weiss W; Ferlitsch M
Endoscopy; 2015 Mar; 47(3):207-16. PubMed ID: 25412094
[TBL] [Abstract][Full Text] [Related]
17. Providing data for serrated polyp detection rate benchmarks: an analysis of the New Hampshire Colonoscopy Registry.
Anderson JC; Butterly LF; Weiss JE; Robinson CM
Gastrointest Endosc; 2017 Jun; 85(6):1188-1194. PubMed ID: 28153571
[TBL] [Abstract][Full Text] [Related]
18. A Single-center Review of Pediatric Colonoscopy Quality Indicators.
Pasquarella CS; Kaplan B; Mahajan L; Lamparyk K; Kay M
J Pediatr Gastroenterol Nutr; 2019 May; 68(5):648-654. PubMed ID: 30562311
[TBL] [Abstract][Full Text] [Related]
19. Evaluating screening age for colonoscopy: a quality assurance assessment.
Overholt BF; Brooks-Belli L; Grace MG; Rankin K; Harrell R; Turyk M; Rosenberg FB; Barish RW; Gilinsky NH;
J Clin Gastroenterol; 2010 Aug; 44(7):e147-53. PubMed ID: 20104186
[TBL] [Abstract][Full Text] [Related]
20. Simple proxies for detection of clinically significant serrated polyps and data for their benchmarks.
Park SK; Park SH; Yang HJ; Jung YS; Park JH; Sohn CI; Park DI
J Gastroenterol Hepatol; 2020 Aug; 35(8):1365-1371. PubMed ID: 31907971
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]