BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

184 related articles for article (PubMed ID: 32008045)

  • 1. Better view by detachable string magnetically controlled capsule endoscopy for esophageal observation: a retrospective comparative study.
    Song J; Bai T; Zhang L; Xiang XL; Xie XP; Hou XH
    Dis Esophagus; 2020 Apr; 33(4):. PubMed ID: 32008045
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Detachable string magnetically controlled capsule endoscopy for complete viewing of the esophagus and stomach.
    Chen YZ; Pan J; Luo YY; Jiang X; Zou WB; Qian YY; Zhou W; Liu X; Li ZS; Liao Z
    Endoscopy; 2019 Apr; 51(4):360-364. PubMed ID: 30822803
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Detachable string magnetically controlled capsule endoscopy for the noninvasive diagnosis of esophageal diseases: A prospective, blind clinical study.
    Yang YL; Qin HW; Chen ZY; Fan HN; Yu Y; Da W; Zhu JS; Zhang J
    World J Gastroenterol; 2024 Mar; 30(9):1121-1131. PubMed ID: 38577194
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Detachable string magnetically controlled capsule endoscopy for complete observation of the upper gastrointestinal tract.
    Xiu H; Lu Y; Liu X; Liu F; Zhang L; Zhao C; Sun X
    Eur J Gastroenterol Hepatol; 2021 Apr; 33(4):508-513. PubMed ID: 32956183
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A novel capsule endoscopy for upper and mid-GI tract: the UMGI capsule.
    Jiang B; Qian YY; Wang YC; Pan J; Jiang X; Zhu JH; Qiu XO; Zhou W; Li ZS; Liao Z
    BMC Gastroenterol; 2023 Mar; 23(1):76. PubMed ID: 36927462
    [TBL] [Abstract][Full Text] [Related]  

  • 6. String esophageal capsule endoscopy with real-time viewing improves visualization of the distal esophageal Z-line: a prospective, comparative study.
    Chen WS; Zhu LH; Li DZ; Chen L; Wu YL; Wang W
    Eur J Gastroenterol Hepatol; 2014 Mar; 26(3):309-12. PubMed ID: 24429971
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Accuracy of Magnetically Controlled Capsule Endoscopy, Compared With Conventional Gastroscopy, in Detection of Gastric Diseases.
    Liao Z; Hou X; Lin-Hu EQ; Sheng JQ; Ge ZZ; Jiang B; Hou XH; Liu JY; Li Z; Huang QY; Zhao XJ; Li N; Gao YJ; Zhang Y; Zhou JQ; Wang XY; Liu J; Xie XP; Yang CM; Liu HL; Sun XT; Zou WB; Li ZS
    Clin Gastroenterol Hepatol; 2016 Sep; 14(9):1266-1273.e1. PubMed ID: 27211503
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Esophageal capsule endoscopy in patients refusing conventional endoscopy for the study of suspected esophageal pathology.
    Sánchez-Yagüe A; Caunedo-Alvarez A; García-Montes JM; Romero-Vázquez J; Pellicer-Bautista FJ; Herrerías-Gutiérrez JM
    Eur J Gastroenterol Hepatol; 2006 Sep; 18(9):977-83. PubMed ID: 16894311
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Is string esophageal capsule endoscopy really better than esophageal capsule endoscopy in the right supine position for Z-line examination?
    Fernandez-Urien I; Jimenez-Perez FJ
    Eur J Gastroenterol Hepatol; 2014 Jun; 26(6):685. PubMed ID: 24781309
    [No Abstract]   [Full Text] [Related]  

  • 10. Esophageal capsule endoscopy in patients with suspected esophageal disease: double blinded comparison with esophagogastroduodenoscopy and assessment of interobserver variability.
    Delvaux M; Papanikolaou IS; Fassler I; Pohl H; Voderholzer W; Rösch T; Gay G
    Endoscopy; 2008 Jan; 40(1):16-22. PubMed ID: 18058656
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Diagnostic accuracy of magnetically guided capsule endoscopy with a detachable string for detecting oesophagogastric varices in adults with cirrhosis: prospective multicentre study.
    Jiang X; Pan J; Xu Q; Song YH; Sun HH; Peng C; Qi XL; Qian YY; Zou WB; Yang Y; Jin SQ; Duan BS; Wu S; Chu Y; Xiao DH; Hu LJ; Cao JZ; Dai JF; Liu X; Xia T; Zhou W; Chen T; Zhou CH; Wu W; Liu SJ; Yang ZY; Wang F; Zhang L; Li CZ; Xu H; Wang JX; Wei B; Lin Y; Deng X; Qu LH; Shen YQ; Wang H; Huang YF; Bao HB; Zhang S; Li L; Shi YH; Wang XY; Zou DW; Wan XJ; Xu MD; Mao H; He CH; Li Z; Zuo XL; He SX; Xie XP; Liu J; Yang CQ; Spada C; Li ZS; Liao Z
    BMJ; 2024 Mar; 384():e078581. PubMed ID: 38443074
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Magnetically Controlled Capsule Endoscopy in Children: A Single-center, Retrospective Cohort Study.
    Gu Z; Wang Y; Lin K; Wang X; Cheng W; Wang L; Zhang T; Liu H
    J Pediatr Gastroenterol Nutr; 2019 Jul; 69(1):13-17. PubMed ID: 30747810
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Capsule endoscopy--not just for the small bowel: a review.
    Parker CE; Spada C; McAlindon M; Davison C; Panter S
    Expert Rev Gastroenterol Hepatol; 2015 Jan; 9(1):79-89. PubMed ID: 25484107
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Radiographic demonstration of a wireless capsule pH monitor in the esophagus.
    Javors BR; Bukman R
    Dysphagia; 2011 Jun; 26(2):193-5. PubMed ID: 20443028
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Magnetic-controlled capsule endoscopy vs. gastroscopy for gastric diseases: a two-center self-controlled comparative trial.
    Zou WB; Hou XH; Xin L; Liu J; Bo LM; Yu GY; Liao Z; Li ZS
    Endoscopy; 2015 Jun; 47(6):525-8. PubMed ID: 25590177
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Is esophageal capsule endoscopy feasible? Results of a pilot.
    Neu B; Wettschureck E; Rösch T
    Endoscopy; 2003 Nov; 35(11):957-61. PubMed ID: 14606020
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Small-sized versus standard magnetic capsule endoscopy in adults: a two-center, double-blinded randomized controlled trial.
    Jiang X; Qiu XO; Li Z; Pan J; Peng C; Zuo XL; Liao Z; Li ZS
    Endoscopy; 2023 Jan; 55(1):52-57. PubMed ID: 35820437
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Magnetically controlled capsule endoscopy as the first-line examination for high-risk patients for the standard gastroscopy: a preliminary study.
    Hu J; Wang S; Ma W; Pan D; Sun S
    Scand J Gastroenterol; 2019 Jul; 54(7):934-937. PubMed ID: 31328998
    [No Abstract]   [Full Text] [Related]  

  • 19. Clinical Efficiency and Safety of Magnetic-Controlled Capsule Endoscopy for Gastric Diseases in Aging Patients: Our Preliminary Experience.
    Zhang S; Sun T; Xie Y; Yu C; Jin S; Yu J; Mao H
    Dig Dis Sci; 2019 Oct; 64(10):2911-2922. PubMed ID: 31032524
    [TBL] [Abstract][Full Text] [Related]  

  • 20. String-mounted double-headed capsule and Z-line detection: is string really the thing?
    Bartzis L; Koulaouzidis A
    Eur J Gastroenterol Hepatol; 2014 Jun; 26(6):685-6. PubMed ID: 24781310
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 10.