These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
302 related articles for article (PubMed ID: 32008342)
21. Is the Anterior Injection Approach Without Ultrasound Guidance Superior to the Posterior Approach for Adhesive Capsulitis of the Shoulder? A Sequential, Prospective Trial. Rijs Z; de Groot PCJ; Zwitser EW; Visser CPJ Clin Orthop Relat Res; 2021 Nov; 479(11):2483-2489. PubMed ID: 33950868 [TBL] [Abstract][Full Text] [Related]
22. Are blind injections of gleno-humeral joint (GHJ) really less accurate imaging-guided injections? A narrative systematic review considering multiple anatomical approaches. Simoni P; Grumolato M; Malaise O; Preziosi M; Pasleau F; de Lemos Esteves F Radiol Med; 2017 Sep; 122(9):656-675. PubMed ID: 28523634 [TBL] [Abstract][Full Text] [Related]
23. Ultrasound guidance for intra-articular knee and shoulder injections: a review. Bookman JS; Pereira DS Bull Hosp Jt Dis (2013); 2014; 72(4):266-70. PubMed ID: 25986350 [TBL] [Abstract][Full Text] [Related]
24. Palpation Versus Ultrasound-Guided Acromioclavicular Joint Intra-articular Corticosteroid Injections: A Retrospective Comparative Clinical Study. Park KD; Kim TK; Lee J; Lee WY; Ahn JK; Park Y Pain Physician; 2015; 18(4):333-41. PubMed ID: 26218936 [TBL] [Abstract][Full Text] [Related]
25. Radiation dose and intra-articular access: comparison of the lateral mortise and anterior midline approaches to fluoroscopically guided tibiotalar joint injections. Huang AJ; Balza R; Torriani M; Bredella MA; Chang CY; Simeone FJ; Palmer WE Skeletal Radiol; 2016 Mar; 45(3):367-73. PubMed ID: 26613732 [TBL] [Abstract][Full Text] [Related]
26. Accuracy of Injection Into the First Dorsal Compartment: A Cadaveric Ultrasound Study. Kutsikovich J; Merrell G J Hand Surg Am; 2018 Aug; 43(8):777.e1-777.e5. PubMed ID: 29478620 [TBL] [Abstract][Full Text] [Related]
28. Ultrasound versus palpation guidance for intra-articular injections in patients with degenerative osteoarthritis of the elbow. Kim TK; Lee JH; Park KD; Lee SC; Ahn J; Park Y J Clin Ultrasound; 2013 Oct; 41(8):479-85. PubMed ID: 23828016 [TBL] [Abstract][Full Text] [Related]
30. Ultrasound-guided injection of the elbow: Cadaveric description for the proximal to distal approach. Ricci V; Mezian K; Chang KV; Mittal N; Kara M; Naňka O; Özçakar L PM R; 2023 Nov; 15(11):1431-1435. PubMed ID: 36864563 [TBL] [Abstract][Full Text] [Related]
31. The influence of ultrasound guidance in the rate of success of acromioclavicular joint injection: an experimental study on human cadavers. Borbas P; Kraus T; Clement H; Grechenig S; Weinberg AM; Heidari N J Shoulder Elbow Surg; 2012 Dec; 21(12):1694-7. PubMed ID: 22475721 [TBL] [Abstract][Full Text] [Related]
32. Sonographically guided distal radioulnar joint injection: technique and validation in a cadaveric model. Smith J; Rizzo M; Sayeed YA; Finnoff JT J Ultrasound Med; 2011 Nov; 30(11):1587-92. PubMed ID: 22039032 [TBL] [Abstract][Full Text] [Related]
34. Comparison of ultrasound-guided versus blind glenohumeral injections: a cadaveric study. Patel DN; Nayyar S; Hasan S; Khatib O; Sidash S; Jazrawi LM J Shoulder Elbow Surg; 2012 Dec; 21(12):1664-8. PubMed ID: 22445159 [TBL] [Abstract][Full Text] [Related]
35. The Accuracy of Common Hand Injections With and Without Ultrasound: An Anatomical Study. To P; McClary KN; Sinclair MK; Stout BA; Foad M; Hiratzka S; Stern PJ Hand (N Y); 2017 Nov; 12(6):591-596. PubMed ID: 28719974 [TBL] [Abstract][Full Text] [Related]
36. Accuracy of palpation-guided and ultrasound-guided needle tip placement into the deep and superficial posterior leg compartments. Peck E; Finnoff JT; Smith J; Curtiss H; Muir J; Hollman JH Am J Sports Med; 2011 Sep; 39(9):1968-74. PubMed ID: 21617254 [TBL] [Abstract][Full Text] [Related]
37. Ultrasound-guided shoulder girdle injections are more accurate and more effective than landmark-guided injections: a systematic review and meta-analysis. Aly AR; Rajasekaran S; Ashworth N Br J Sports Med; 2015 Aug; 49(16):1042-9. PubMed ID: 25403682 [TBL] [Abstract][Full Text] [Related]
38. Landmark-Guided and Ultrasound-Guided Approaches for Trochanteric Bursa Injection: A Cadaveric Study. Mu A; Peng P; Agur A Anesth Analg; 2017 Mar; 124(3):966-971. PubMed ID: 28079582 [TBL] [Abstract][Full Text] [Related]
39. Accuracy of ultrasound-guided and palpation-guided knee injections by an experienced and less-experienced injector using a superolateral approach: a cadaveric study. Curtiss HM; Finnoff JT; Peck E; Hollman J; Muir J; Smith J PM R; 2011 Jun; 3(6):507-15. PubMed ID: 21665162 [TBL] [Abstract][Full Text] [Related]
40. Accuracy of ultrasound-guided versus fluoroscopically guided contrast-controlled piriformis injections: a cadaveric study. Finnoff JT; Hurdle MF; Smith J J Ultrasound Med; 2008 Aug; 27(8):1157-63. PubMed ID: 18645073 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]