These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

132 related articles for article (PubMed ID: 32009074)

  • 21. Finite element analysis: a comparison of an all-polyethylene tibial implant and its metal-backed equivalent.
    Thompson SM; Yohuno D; Bradley WN; Crocombe AD
    Knee Surg Sports Traumatol Arthrosc; 2016 Aug; 24(8):2560-6. PubMed ID: 26694487
    [TBL] [Abstract][Full Text] [Related]  

  • 22. [Influence of rotatory malposition of femoral implant in failure of unicompartimental medial knee prosthesis].
    Assor M; Aubaniac JM
    Rev Chir Orthop Reparatrice Appar Mot; 2006 Sep; 92(5):473-84. PubMed ID: 17088741
    [TBL] [Abstract][Full Text] [Related]  

  • 23. The Valgus Inclination of the Tibial Component Increases the Risk of Medial Tibial Condylar Fractures in Unicompartmental Knee Arthroplasty.
    Inoue S; Akagi M; Asada S; Mori S; Zaima H; Hashida M
    J Arthroplasty; 2016 Sep; 31(9):2025-30. PubMed ID: 27038862
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Unicompartmental Knee Arthroplasty Provides Higher Activity and Durability Than Valgus-Producing Proximal Tibial Osteotomy at 5 to 7 Years.
    Krych AJ; Reardon P; Sousa P; Pareek A; Stuart M; Pagnano M
    J Bone Joint Surg Am; 2017 Jan; 99(2):113-122. PubMed ID: 28099301
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Revision of Unicompartmental to Total Knee Arthroplasty: Does the Unicompartmental Implant (Metal-Backed vs All-Polyethylene) Impact the Total Knee Arthroplasty?
    Scott CEH; Powell-Bowns MFR; MacDonald DJ; Simpson PM; Wade FA
    J Arthroplasty; 2018 Jul; 33(7):2203-2209. PubMed ID: 29525342
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Biomechanical effects of posterior tibial slope on unicompartmental knee arthroplasty using finite element analysis.
    Kang KT; Park JH; Koh YG; Shin J; Park KK
    Biomed Mater Eng; 2019; 30(2):133-144. PubMed ID: 30741662
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Elevated proximal tibial strains following unicompartmental knee replacement--a possible cause of pain.
    Simpson DJ; Price AJ; Gulati A; Murray DW; Gill HS
    Med Eng Phys; 2009 Sep; 31(7):752-7. PubMed ID: 19278893
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Predictive factors for satisfaction after contemporary unicompartmental knee arthroplasty and high tibial osteotomy in isolated medial femorotibial osteoarthritis.
    Koh IJ; Kim MS; Sohn S; Song KY; Choi NY; Jung H; In Y
    Orthop Traumatol Surg Res; 2019 Feb; 105(1):77-83. PubMed ID: 30509622
    [TBL] [Abstract][Full Text] [Related]  

  • 29. All-polyethylene tibial components generate higher stress and micromotions than metal-backed tibial components in total knee arthroplasty.
    Brihault J; Navacchia A; Pianigiani S; Labey L; De Corte R; Pascale V; Innocenti B
    Knee Surg Sports Traumatol Arthrosc; 2016 Aug; 24(8):2550-9. PubMed ID: 25957612
    [TBL] [Abstract][Full Text] [Related]  

  • 30. The effect of bearing congruency, thickness and alignment on the stresses in unicompartmental knee replacements.
    Simpson DJ; Gray H; D'Lima D; Murray DW; Gill HS
    Clin Biomech (Bristol, Avon); 2008 Nov; 23(9):1148-57. PubMed ID: 18639960
    [TBL] [Abstract][Full Text] [Related]  

  • 31. The influence of tibial component malalignment on bone strain in revision total knee replacement.
    Rastetter BR; Wright SJ; Gheduzzi S; Miles AW; Clift SE
    Proc Inst Mech Eng H; 2016 Jun; 230(6):561-8. PubMed ID: 27006420
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Metal-backed versus all-polyethylene unicompartmental knee arthroplasty: Proximal tibial strain in an experimentally validated finite element model.
    Scott CE; Eaton MJ; Nutton RW; Wade FA; Evans SL; Pankaj P
    Bone Joint Res; 2017 Jan; 6(1):22-30. PubMed ID: 28077394
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Biomechanical analysis of all-polyethylene total knee arthroplasty on periprosthetic tibia using the finite element method.
    Apostolopoulos V; Tomáš T; Boháč P; Marcián P; Mahdal M; Valoušek T; Janíček P; Nachtnebl L
    Comput Methods Programs Biomed; 2022 Jun; 220():106834. PubMed ID: 35490458
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Alignment in total knee arthroplasty following failed high tibial osteotomy.
    Kawano T; Miura H; Nagamine R; Urabe K; Matsuda S; Mawatari T; Moro-Oka T; Iwamoto Y
    J Knee Surg; 2003 Jul; 16(3):168-72. PubMed ID: 12943287
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Predicting the effect of tray malalignment on risk for bone damage and implant subsidence after total knee arthroplasty.
    Wong J; Steklov N; Patil S; Flores-Hernandez C; Kester M; Colwell CW; D'Lima DD
    J Orthop Res; 2011 Mar; 29(3):347-53. PubMed ID: 20882595
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Stress shielding in periprosthetic bone following a total knee replacement: Effects of implant material, design and alignment.
    Zhang QH; Cossey A; Tong J
    Med Eng Phys; 2016 Dec; 38(12):1481-1488. PubMed ID: 27745873
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Analysis of an early intervention tibial component for medial osteoarthritis.
    Chaudhary ME; Walker PS
    J Biomech Eng; 2014 Jun; 136(6):061008. PubMed ID: 24749143
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Obliquity of tibial component after unicompartmental knee arthroplasty.
    Asada S; Inoue S; Tsukamoto I; Mori S; Akagi M
    Knee; 2019 Mar; 26(2):410-415. PubMed ID: 30691990
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Finite-element analysis of the proximal tibial sclerotic bone and different alignment in total knee arthroplasty.
    Li YR; Gao YH; Yang C; Ding L; Zhang X; Chen H; Liu J; Qi X
    BMC Musculoskelet Disord; 2019 Dec; 20(1):617. PubMed ID: 31878972
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Medial joint line elevation of the tibia measured during surgery has a significant correlation with the limb alignment changes following medial unicompartmental knee arthroplasty.
    Kuroda Y; Takayama K; Ishida K; Hayashi S; Hashimoto S; Tsubosaka M; Matsushita T; Niikura T; Nishida K; Kuroda R; Matsumoto T
    Knee Surg Sports Traumatol Arthrosc; 2018 Nov; 26(11):3468-3473. PubMed ID: 29663012
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.