These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

132 related articles for article (PubMed ID: 32011575)

  • 1. Assessing the Impact of En Face Retinal Nerve Fiber Layer Imaging on Clinical Decision Making for Glaucoma Suspects.
    King BJ; Swanson WH; Klemencic SA; Chaglasian M; Teitelbaum BA; Clark CA; Speilburg AM; Grogg JA; Peabody TD
    Optom Vis Sci; 2020 Feb; 97(2):54-61. PubMed ID: 32011575
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The Influence of Optical Coherence Tomography Measurements of Retinal Nerve Fiber Layer on Decision-Making in Glaucoma Diagnosis.
    Fu L; Aspinall P; Bennett G; Magidson J; Tatham AJ
    Curr Eye Res; 2017 Apr; 42(4):575-582. PubMed ID: 27754717
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Relationship between standard automated perimetry and retinal nerve fiber layer parameters obtained with optical coherence tomography.
    Lopez-Peña MJ; Ferreras A; Larrosa JM; Polo V; Pablo LE
    J Glaucoma; 2011 Sep; 20(7):422-32. PubMed ID: 21278593
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Correlation of frequency-doubling perimetry with retinal nerve fiber layer thickness and optic disc size in ocular hypertensives and glaucoma suspects.
    Kaushik S; Pandav SS; Ichhpujani P; Gupta A
    J Glaucoma; 2011 Aug; 20(6):366-70. PubMed ID: 20717056
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Functional characteristics of glaucoma related arcuate defects seen on OCT en face visualisation of the retinal nerve fibre layer.
    Ashimatey BS; King BJ; Swanson WH
    Ophthalmic Physiol Opt; 2021 Mar; 41(2):437-446. PubMed ID: 33492742
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Optical coherence tomography longitudinal evaluation of retinal nerve fiber layer thickness in glaucoma.
    Wollstein G; Schuman JS; Price LL; Aydin A; Stark PC; Hertzmark E; Lai E; Ishikawa H; Mattox C; Fujimoto JG; Paunescu LA
    Arch Ophthalmol; 2005 Apr; 123(4):464-70. PubMed ID: 15824218
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Pattern electroretinogram changes in patients with primary open-angle glaucoma in correlation with visual field and optical coherence tomography changes.
    Elgohary AM; Elbedewy HA; Saad HA; Eid TM
    Eur J Ophthalmol; 2020 Nov; 30(6):1362-1369. PubMed ID: 31496271
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of the Retinal Nerve Fiber Layer Thickness, the Mean Deviation, and the Visual Field Index in Progressive Glaucoma.
    Banegas SA; Antón A; Morilla A; Bogado M; Ayala EM; Fernandez-Guardiola A; Moreno-Montañes J
    J Glaucoma; 2016 Mar; 25(3):e229-35. PubMed ID: 26020689
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Can Automated Imaging for Optic Disc and Retinal Nerve Fiber Layer Analysis Aid Glaucoma Detection?
    Banister K; Boachie C; Bourne R; Cook J; Burr JM; Ramsay C; Garway-Heath D; Gray J; McMeekin P; Hernández R; Azuara-Blanco A
    Ophthalmology; 2016 May; 123(5):930-8. PubMed ID: 27016459
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Correlation between early retinal nerve fiber layer loss and visual field loss determined by three different perimetric strategies: white-on-white, frequency-doubling, or flicker-defined form perimetry.
    Prokosch V; Eter N
    Graefes Arch Clin Exp Ophthalmol; 2014 Oct; 252(10):1599-606. PubMed ID: 25074041
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Retinal nerve fiber layer damage as assessed by optical coherence tomography in eyes with a visual field defect detected by frequency doubling technology perimetry but not by standard automated perimetry.
    Kim TW; Zangwill LM; Bowd C; Sample PA; Shah N; Weinreb RN
    Ophthalmology; 2007 Jun; 114(6):1053-7. PubMed ID: 17239441
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Diagnostic Accuracy of Technologies for Glaucoma Case-Finding in a Community Setting.
    Dabasia PL; Fidalgo BR; Edgar DF; Garway-Heath DF; Lawrenson JG
    Ophthalmology; 2015 Dec; 122(12):2407-15. PubMed ID: 26411836
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Retinal nerve fiber layer thickness measured with optical coherence tomography is related to visual function in glaucomatous eyes.
    El Beltagi TA; Bowd C; Boden C; Amini P; Sample PA; Zangwill LM; Weinreb RN
    Ophthalmology; 2003 Nov; 110(11):2185-91. PubMed ID: 14597528
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Circumpapillary microperimetry to detect glaucoma: a pilot study for sector-based comparison to circumpapillary retinal nerve fiber layer measurement.
    Kita Y; Hollό G; Saito T; Murai A; Kita R; Hirakata A
    Int Ophthalmol; 2019 Jan; 39(1):127-136. PubMed ID: 29249069
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Concordance of Objectively Detected Retinal Nerve Fiber Bundle Defects in En Face OCT Images with Conventional Structural and Functional Changes in Glaucoma.
    Cheloni R; Denniss J
    Ophthalmol Glaucoma; 2023; 6(1):78-92. PubMed ID: 35835434
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of macular ganglion cell analysis compared to retinal nerve fiber layer thickness for preperimetric glaucoma diagnosis.
    Kaushik S; Kataria P; Jain V; Joshi G; Raj S; Pandav SS
    Indian J Ophthalmol; 2018 Apr; 66(4):511-516. PubMed ID: 29582810
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Baseline optical coherence tomography predicts the development of glaucomatous change in glaucoma suspects.
    Lalezary M; Medeiros FA; Weinreb RN; Bowd C; Sample PA; Tavares IM; Tafreshi A; Zangwill LM
    Am J Ophthalmol; 2006 Oct; 142(4):576-82. PubMed ID: 17011848
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Optical coherence tomography and scanning laser polarimetry in normal, ocular hypertensive, and glaucomatous eyes.
    Hoh ST; Greenfield DS; Mistlberger A; Liebmann JM; Ishikawa H; Ritch R
    Am J Ophthalmol; 2000 Feb; 129(2):129-35. PubMed ID: 10682963
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Assessment of retinal nerve fiber layer internal reflectivity in eyes with and without glaucoma using optical coherence tomography.
    Pons ME; Ishikawa H; Gürses-Ozden R; Liebmann JM; Dou HL; Ritch R
    Arch Ophthalmol; 2000 Aug; 118(8):1044-7. PubMed ID: 10922196
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Localized Retinal Nerve Fiber Layer Defects in Red-free Photographs Versus En Face Structural Optical Coherence Tomography Images.
    Jung JH; Park JH; Yoo C; Kim YY
    J Glaucoma; 2018 Mar; 27(3):269-274. PubMed ID: 29303874
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.