These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
144 related articles for article (PubMed ID: 32014549)
1. Venous Drainage of Lumbar Vertebral Bodies: Anatomic Study with Application to Kyphoplasty, Vertebroplasty, and Pedicle Screw Complications. Iwanaga J; Rustagi T; Ishak B; Johal J; David G; Reina MA; Dumont AS; Tubbs RS World Neurosurg; 2020 May; 137():e286-e290. PubMed ID: 32014549 [TBL] [Abstract][Full Text] [Related]
2. Risk of cement leakage and pulmonary embolism by bone cement-augmented pedicle screw fixation of the thoracolumbar spine. Janssen I; Ryang YM; Gempt J; Bette S; Gerhardt J; Kirschke JS; Meyer B Spine J; 2017 Jun; 17(6):837-844. PubMed ID: 28108403 [TBL] [Abstract][Full Text] [Related]
3. A mysterious risk factor for bone cement leakage into the spinal canal through the Batson vein during percutaneous kyphoplasty: a case control study. Zhang S; Wang GJ; Wang Q; Yang J; Xu S; Yang CH BMC Musculoskelet Disord; 2019 Sep; 20(1):423. PubMed ID: 31510985 [TBL] [Abstract][Full Text] [Related]
4. Anatomical and pathological considerations in percutaneous vertebroplasty and kyphoplasty: a reappraisal of the vertebral venous system. Groen RJ; du Toit DF; Phillips FM; Hoogland PV; Kuizenga K; Coppes MH; Muller CJ; Grobbelaar M; Mattyssen J Spine (Phila Pa 1976); 2004 Jul; 29(13):1465-71. PubMed ID: 15223940 [TBL] [Abstract][Full Text] [Related]
5. [Cement embolism in the vena cava after pedicle screw augmentation]. David S; Kleber FX Unfallchirurg; 2021 Jun; 124(6):512-516. PubMed ID: 33201267 [TBL] [Abstract][Full Text] [Related]
6. Biomechanical evaluation of calcium phosphate-based nanocomposite versus polymethylmethacrylate cement for percutaneous kyphoplasty. Lu Q; Liu C; Wang D; Liu H; Yang H; Yang L Spine J; 2019 Nov; 19(11):1871-1884. PubMed ID: 31202837 [TBL] [Abstract][Full Text] [Related]
7. Inferior vena cava syndrome following percutaneous vertebroplasty with polymethylmethacrylate. Kao FC; Tu YK; Lai PL; Yu SW; Yen CY; Chou MC Spine (Phila Pa 1976); 2008 May; 33(10):E329-33. PubMed ID: 18449034 [TBL] [Abstract][Full Text] [Related]
8. Polymethylmethacrylate distribution is associated with recompression after vertebroplasty or kyphoplasty for osteoporotic vertebral compression fractures: A retrospective study. Hou Y; Yao Q; Zhang G; Ding L; Huang H PLoS One; 2018; 13(6):e0198407. PubMed ID: 29856859 [TBL] [Abstract][Full Text] [Related]
9. Prevention of cardiopulmonary embolization of polymethylmethacrylate cement fragment after kyphoplasty with insertion of inferior vena cava filter. Agko M; Nazzal M; Jamil T; Castillo-Sang M; Clark P; Kasper G J Vasc Surg; 2010 Jan; 51(1):210-3. PubMed ID: 19837540 [TBL] [Abstract][Full Text] [Related]
10. Successful thrombolysis, angioplasty, and stenting of delayed thrombosis in the vena cava following percutaneous vertebroplasty with polymethylmethacrylate cement. Kim SM; Min SK; Jae HJ; Min SI; Ha J; Kim SJ J Vasc Surg; 2012 Oct; 56(4):1119-23. PubMed ID: 22572011 [TBL] [Abstract][Full Text] [Related]
11. Pulmonary embolism caused by acrylic cement: a rare complication of percutaneous vertebroplasty. Padovani B; Kasriel O; Brunner P; Peretti-Viton P AJNR Am J Neuroradiol; 1999 Mar; 20(3):375-7. PubMed ID: 10219399 [TBL] [Abstract][Full Text] [Related]
12. Primary pedicle screw augmentation in osteoporotic lumbar vertebrae: biomechanical analysis of pedicle fixation strength. Burval DJ; McLain RF; Milks R; Inceoglu S Spine (Phila Pa 1976); 2007 May; 32(10):1077-83. PubMed ID: 17471088 [TBL] [Abstract][Full Text] [Related]
13. Biomechanical behavior of MRI-signal-inducing bone cements after vertebroplasty in osteoporotic vertebral bodies: An experimental cadaver study. Wichlas F; Trzenschik H; Tsitsilonis S; Rohlmann A; Bail HJ Clin Biomech (Bristol); 2014 May; 29(5):571-6. PubMed ID: 24703828 [TBL] [Abstract][Full Text] [Related]
14. [Polymethylmethacrylate augmentation of bone cement-injectable cannulated pedicle screws for the treatment of degenerative lumbar diseases with osteoporosis]. Sun HL; Li CD; Yang ZC; Yi XD; Liu H; Lu HL; Li H; Wang Y Beijing Da Xue Xue Bao Yi Xue Ban; 2016 Dec; 48(6):1019-1025. PubMed ID: 27987507 [TBL] [Abstract][Full Text] [Related]
15. The effect of pulsed jet lavage in vertebroplasty on injection forces of polymethylmethacrylate bone cement, material distribution, and potential fat embolism: a cadaver study. Benneker LM; Heini PF; Suhm N; Gisep A Spine (Phila Pa 1976); 2008 Nov; 33(23):E906-10. PubMed ID: 18978585 [TBL] [Abstract][Full Text] [Related]
16. Prevention of Pulmonary Cement Embolism by Inferior Vena Cava Filter following Vertebroplasty-related Cement Intravasation. Prater S; Awan MA; Antuna K; Colon JZ J Radiol Case Rep; 2021 Apr; 15(4):17-27. PubMed ID: 34276872 [TBL] [Abstract][Full Text] [Related]
17. Decreased extrusion of calcium phosphate cement versus high viscosity PMMA cement into spongious bone marrow-an ex vivo and in vivo study in sheep vertebrae. Xin L; Bungartz M; Maenz S; Horbert V; Hennig M; Illerhaus B; Günster J; Bossert J; Bischoff S; Borowski J; Schubert H; Jandt KD; Kunisch E; Kinne RW; Brinkmann O Spine J; 2016 Dec; 16(12):1468-1477. PubMed ID: 27496285 [TBL] [Abstract][Full Text] [Related]
18. Cement pulmonary embolism after percutaneous vertebroplasty and kyphoplasty: an overview. Habib N; Maniatis T; Ahmed S; Kilkenny T; Alkaied H; Elsayegh D; Chalhoub M; Harris K Heart Lung; 2012; 41(5):509-11. PubMed ID: 22425258 [TBL] [Abstract][Full Text] [Related]
19. Infection following percutaneous vertebral augmentation with polymethylmethacrylate. Park JW; Park SM; Lee HJ; Lee CK; Chang BS; Kim H Arch Osteoporos; 2018 Apr; 13(1):47. PubMed ID: 29704173 [TBL] [Abstract][Full Text] [Related]