These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
174 related articles for article (PubMed ID: 32015218)
1. Correlation between breath ammonia and blood urea nitrogen levels in chronic kidney disease and dialysis patients. Chen CC; Hsieh JC; Chao CH; Yang WS; Cheng HT; Chan CK; Lu CJ; Meng HF; Zan HW J Breath Res; 2020 Apr; 14(3):036002. PubMed ID: 32015218 [TBL] [Abstract][Full Text] [Related]
2. Biochemical pathways of breath ammonia (NH3) generation in patients with end-stage renal disease undergoing hemodialysis. Chen W; Laiho S; Vaittinen O; Halonen L; Ortiz F; Forsblom C; Groop PH; Lehto M; Metsälä M J Breath Res; 2016 Aug; 10(3):036011. PubMed ID: 27516572 [TBL] [Abstract][Full Text] [Related]
3. The breath ammonia measurement of the hemodialysis with a QCM-NH3 sensor. Ishida H; Satou T; Tsuji K; Kawashima N; Takemura H; Kosaki Y; Shiratori S; Agishi T Biomed Mater Eng; 2008; 18(2):99-106. PubMed ID: 18408261 [TBL] [Abstract][Full Text] [Related]
4. Real-time monitoring of breath ammonia during haemodialysis: use of ion mobility spectrometry (IMS) and cavity ring-down spectroscopy (CRDS) techniques. Neri G; Lacquaniti A; Rizzo G; Donato N; Latino M; Buemi M Nephrol Dial Transplant; 2012 Jul; 27(7):2945-52. PubMed ID: 22492831 [TBL] [Abstract][Full Text] [Related]
5. Correlation of breath ammonia with blood urea nitrogen and creatinine during hemodialysis. Narasimhan LR; Goodman W; Patel CK Proc Natl Acad Sci U S A; 2001 Apr; 98(8):4617-21. PubMed ID: 11296293 [TBL] [Abstract][Full Text] [Related]
6. Applications of external cavity diode laser-based technique to noninvasive clinical diagnosis using expired breath ammonia analysis: chronic kidney disease, epilepsy. Bayrakli I; Turkmen A; Akman H; Sezer MT; Kutluhan S J Biomed Opt; 2016 Aug; 21(8):87004. PubMed ID: 27533447 [TBL] [Abstract][Full Text] [Related]
7. The origin of mouth-exhaled ammonia. Chen W; Metsälä M; Vaittinen O; Halonen L J Breath Res; 2014 Sep; 8(3):036003. PubMed ID: 25080054 [TBL] [Abstract][Full Text] [Related]
8. Organic Gas Sensor with an Improved Lifetime for Detecting Breath Ammonia in Hemodialysis Patients. Chuang MY; Chen CC; Zan HW; Meng HF; Lu CJ ACS Sens; 2017 Dec; 2(12):1788-1795. PubMed ID: 29124925 [TBL] [Abstract][Full Text] [Related]
9. A breath ammonia analyser for monitoring patients with end-stage renal disease on haemodialysis. Limeres J; Garcez JF; Marinho JS; Loureiro A; Diniz M; Diz P Br J Biomed Sci; 2017 Jan; 74(1):24-29. PubMed ID: 27976989 [TBL] [Abstract][Full Text] [Related]
10. Point of care monitoring of hemodialysis patients with a breath ammonia measurement device based on printed polyaniline nanoparticle sensors. Hibbard T; Crowley K; Kelly F; Ward F; Holian J; Watson A; Killard AJ Anal Chem; 2013 Dec; 85(24):12158-65. PubMed ID: 24299143 [TBL] [Abstract][Full Text] [Related]
11. Measurement of breath ammonia for detection of patients with chronic kidney disease. Bevc S; Mohorko E; Kolar M; Brglez P; Holobar A; Kniepeiss D; Podbregar M; Piko N; Hojs N; Knehtl M; Ekart R; Hojs R Clin Nephrol; 2017 Supplement 1; 88(13):14-17. PubMed ID: 28601120 [TBL] [Abstract][Full Text] [Related]
12. Can salivary creatinine and urea levels be used to diagnose chronic kidney disease in children as accurately as serum creatinine and urea levels? A case-control study. Renda R Ren Fail; 2017 Nov; 39(1):452-457. PubMed ID: 28372505 [TBL] [Abstract][Full Text] [Related]
13. A Versatile Method to Enhance the Operational Current of Air-Stable Organic Gas Sensor for Monitoring of Breath Ammonia in Hemodialysis Patients. Yu SY; Tung TW; Yang HY; Chen GY; Shih CC; Lee YC; Chen CC; Zan HW; Meng HF; Lu CJ; Wang CL; Jian WB; Soppera O ACS Sens; 2019 Apr; 4(4):1023-1031. PubMed ID: 30892019 [TBL] [Abstract][Full Text] [Related]
14. Photoacoustic detection of ammonia exhaled by individuals with chronic kidney disease. Silva LG; Bueno SCE; da Silva MG; Mota L; Sthel MS; de Castro MPP; Santiago Neto RM; Kuba VM Lasers Med Sci; 2022 Mar; 37(2):983-991. PubMed ID: 34050494 [TBL] [Abstract][Full Text] [Related]
15. Breath analysis in patients with end-stage renal disease: effect of haemodialysis. Rolla G; Bruno M; Bommarito L; Heffler E; Ferrero N; Petrarulo M; Bagnis C; Bugiani M; Guida G Eur J Clin Invest; 2008 Oct; 38(10):728-33. PubMed ID: 18837798 [TBL] [Abstract][Full Text] [Related]
16. Breath ammonia and trimethylamine allow real-time monitoring of haemodialysis efficacy. Endre ZH; Pickering JW; Storer MK; Hu WP; Moorhead KT; Allardyce R; McGregor DO; Scotter JM Physiol Meas; 2011 Jan; 32(1):115-30. PubMed ID: 21149927 [TBL] [Abstract][Full Text] [Related]
17. Effects of end-stage renal disease and dialysis modalities on blood ammonia level. Vaziri ND; Khazaeli M; Nunes ACF; Harley KT; Said H; Alipour O; Lau WL; Pahl MV Hemodial Int; 2017 Jul; 21(3):343-347. PubMed ID: 27804262 [TBL] [Abstract][Full Text] [Related]
18. Salivary creatinine and urea in patients with end-stage chronic kidney disease could not be used as diagnostic biomarkers for the effectiveness of dialysis treatment. Nogalcheva AN; Konstantinova D; Pechalova P G Ital Nefrol; 2018 Dec; 35(6):. PubMed ID: 30550042 [TBL] [Abstract][Full Text] [Related]
19. Ratio of blood urea nitrogen to serum creatinine at initiation of dialysis is associated with mortality: a multicenter prospective cohort study. Inaguma D; Koide S; Ito E; Takahashi K; Hayashi H; Hasegawa M; Yuzawa Y; Clin Exp Nephrol; 2018 Apr; 22(2):353-364. PubMed ID: 28766029 [TBL] [Abstract][Full Text] [Related]
20. Validation of the salivary urea and creatinine tests as screening methods of chronic kidney disease in Vietnamese patients. Pham TAV Acta Odontol Scand; 2017 Nov; 75(8):551-556. PubMed ID: 28724318 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]