These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

112 related articles for article (PubMed ID: 32015305)

  • 1. [Experimental simulation for determining optimal design parameters of a transpalpebral tonometry sensor].
    Iomdina EN; Klevtsov EA; Ivanishchev KV; Kiseleva OA; Bessmertny AM; Filippova OM; Luzhnov PV; Shamaev DM; Uslontsev DN
    Vestn Oftalmol; 2019; 135(6):27-32. PubMed ID: 32015305
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Measurement of the intraocular pressure with the "transpalpebral tonometer" TGDc-01 in comparison with applanation tonometry.
    Sandner D; Böhm A; Kostov S; Pillunat L
    Graefes Arch Clin Exp Ophthalmol; 2005 Jun; 243(6):563-9. PubMed ID: 15614540
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Transpalpebral tonometer for measuring intraocular pressure].
    Nesterov AP; Piletskiĭ GK; Piletskiĭ NG
    Vestn Oftalmol; 2003; 119(1):3-5. PubMed ID: 12608032
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Transpalpebral measurement of intraocular pressure using the TGDc-01 tonometer versus standard Goldmann applanation tonometry.
    Lösch A; Scheuerle A; Rupp V; Auffarth G; Becker M
    Graefes Arch Clin Exp Ophthalmol; 2005 Apr; 243(4):313-6. PubMed ID: 15864620
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Measurements of intraocular pressure by Goldmann tonometry, Tonopen XL, and the transpalpebral tonometer, TGDc-01, after penetrating keratoplasty: a comparativye study.
    Shemesh G; Waisbourd M; Varssano D; Michaeli A; Lazar M; Kurtz S
    Cornea; 2009 Aug; 28(7):724-7. PubMed ID: 19574919
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Transpalpebral tonometry with a digital tonometer in healthy eyes and after penetrating keratoplasty].
    Amm M; Hedderich J
    Ophthalmologe; 2005 Jan; 102(1):70-6. PubMed ID: 15322801
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Possibilities of monitoring intraocular pressure in children using EASYTON transpalpebral tonometer.
    Iomdina EN; Kushnarevich NY
    Int Ophthalmol; 2022 May; 42(5):1631-1638. PubMed ID: 35088357
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Deviations between transpalpebral tonometry using TGDc-01 and Goldmann applanation tonometry depending on the IOP level.
    Troost A; Specht K; Krummenauer F; Yun SH; Schwenn O
    Graefes Arch Clin Exp Ophthalmol; 2005 Sep; 243(9):853-8. PubMed ID: 16158308
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparison of the transpalpebral tonometer TGDc-01 with Goldmann applanation tonometry.
    Waisbourd M; Shemesh G; Top LB; Lazar M; Loewenstein A
    Eur J Ophthalmol; 2010; 20(5):902-6. PubMed ID: 20306444
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Intraocular pressure difference in Goldmann applanation tonometry versus a transpalpebral tonometer TGDc-01"PRA" in glaucoma patients].
    Schlote T; Landenberger H
    Klin Monbl Augenheilkd; 2005 Feb; 222(2):123-31. PubMed ID: 15719316
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [How does central cornea thickness influence intraocular pressure during applanation and contour tonometry?].
    Schwenteck T; Knappe M; Moros I
    Klin Monbl Augenheilkd; 2012 Sep; 229(9):917-27. PubMed ID: 22972357
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The Utility of Diaton Tonometer Measurements in Patients With Ocular Hypertension, Glaucoma, and Glaucoma Tube Shunts: A Preliminary Study for its Potential Use in Keratoprosthesis Patients.
    Risma JM; Tehrani S; Wang K; Fingert JH; Alward WL; Kwon YH
    J Glaucoma; 2016 Aug; 25(8):643-7. PubMed ID: 26950582
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Intraocular pressure measurement inside the anterior chamber: a new technical solution and results].
    Avetisov SE; Antonov AA; Vostrukhin SV; Avetisov KS
    Vestn Oftalmol; 2016; 132(6):4-10. PubMed ID: 28121293
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Possibilities of using of transpalpebral acoustic tonometry in pediatric ophthalmology].
    Obrubov SA; Rogozhina IV; Mishustin AV
    Vestn Oftalmol; 2005; 121(3):23-5. PubMed ID: 16075625
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Accuracy of dynamic contour tonometry compared with applanation tonometry in human cadaver eyes of different hydration states.
    Kniestedt C; Nee M; Stamper RL
    Graefes Arch Clin Exp Ophthalmol; 2005 Apr; 243(4):359-66. PubMed ID: 15864625
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Schiotz tonometry accurately measures intraocular pressure in Boston type 1 keratoprosthesis eyes.
    Estrovich IE; Shen C; Chu Y; Downs JC; Gardiner S; Straiko M; Mansberger SL
    Cornea; 2015 Jun; 34(6):682-5. PubMed ID: 25782403
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [A new TGDts-01 DIATON transpalpebral tonometer].
    Nesterov AP; Illarionova AR; Obruch BV
    Vestn Oftalmol; 2007; 123(1):42-4. PubMed ID: 17361805
    [No Abstract]   [Full Text] [Related]  

  • 18. Change in intraocular pressure during point-of-care ultrasound.
    Berg C; Doniger SJ; Zaia B; Williams SR
    West J Emerg Med; 2015 Mar; 16(2):263-8. PubMed ID: 25834668
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Ocuton-S self tonometry vs. Goldmann tonometry; a diurnal comparison study.
    Kóthy P; Vargha P; Holló G
    Acta Ophthalmol Scand; 2001 Jun; 79(3):294-7. PubMed ID: 11401642
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Evaluation of intraocular pressure change after laser in situ keratomileusis using the pressure phosphene tonometer.
    Naruse S; Mori K; Kojo M; Hieda O; Kinoshita S
    J Cataract Refract Surg; 2004 Feb; 30(2):390-7. PubMed ID: 15030829
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.