These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

162 related articles for article (PubMed ID: 32019292)

  • 1. The role of platelet function analyzer-200 in predicting perioperative bleeding risk.
    Yu ES; Jeon MJ; Kang KW; Lee BH; Kang EJ; Park Y; Lee SR; Sung HJ; Choi CW; Kim BS; Kim DS
    Korean J Intern Med; 2020 Sep; 35(5):1199-1209. PubMed ID: 32019292
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Perioperative monitoring of primary and secondary hemostasis in coronary artery bypass grafting.
    Hertfelder HJ; Bös M; Weber D; Winkler K; Hanfland P; Preusse CJ
    Semin Thromb Hemost; 2005; 31(4):426-40. PubMed ID: 16149021
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Evaluation of acquired platelet dysfunctions in uremic and cirrhotic patients using the platelet function analyzer (PFA-100 ): influence of hematocrit elevation.
    Escolar G; Cases A; Viñas M; Pino M; Calls J; Cirera I; Ordinas A
    Haematologica; 1999 Jul; 84(7):614-9. PubMed ID: 10406903
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effects of increased von Willebrand factor levels on primary hemostasis in thrombocytopenic patients with liver cirrhosis.
    Wannhoff A; Müller OJ; Friedrich K; Rupp C; Klöters-Plachky P; Leopold Y; Brune M; Senner M; Weiss KH; Stremmel W; Schemmer P; Katus HA; Gotthardt DN
    PLoS One; 2014; 9(11):e112583. PubMed ID: 25397410
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of PFA-100 and bleeding time testing in pediatric patients with suspected hemorrhagic problems.
    Cariappa R; Wilhite TR; Parvin CA; Luchtman-Jones L
    J Pediatr Hematol Oncol; 2003 Jun; 25(6):474-9. PubMed ID: 12794526
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The assessment of PFA-100 test for the estimation of blood loss in renal transplantation operation.
    Ertug Z; Celik U; Hadimioglu N; Dinckan A; Ozdem S
    Ann Transplant; 2010; 15(1):46-52. PubMed ID: 20305318
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Performance evaluation of the Anysis-200 platelet function analyzer in cardiac patients.
    Park SJ; Yoon J; Seo HS; Lim CS
    Clin Hemorheol Microcirc; 2022; 80(1):17-24. PubMed ID: 32116240
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Usefulness of PFA-100 testing in the diagnostic screening of patients with suspected abnormalities of hemostasis: comparison with the bleeding time.
    Podda GM; Bucciarelli P; Lussana F; Lecchi A; Cattaneo M
    J Thromb Haemost; 2007 Dec; 5(12):2393-8. PubMed ID: 18034764
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Primary hemostasis in neonates with thrombocytopenia.
    Deschmann E; Sola-Visner M; Saxonhouse MA
    J Pediatr; 2014 Jan; 164(1):167-72. PubMed ID: 24094764
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Assessment of platelet function analyzer (PFA-100) in kidney transplant patients before renal allograft biopsy: a retrospective single-center analysis.
    Ranghino A; Mella A; Borchiellini A; Nappo A; Manzione AM; Gallo E; Giovinazzo G; Fop F; Segoloni GP; Biancone L
    Transplant Proc; 2014 Sep; 46(7):2259-62. PubMed ID: 25242765
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effectiveness of Platelet Function Analyzer-100 for Laboratory Detection of Anti-Platelet Drug-Induced Platelet Dysfunction.
    Kweon OJ; Lim YK; Kim B; Lee MK; Kim HR
    Ann Lab Med; 2019 Jan; 39(1):23-30. PubMed ID: 30215226
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Prospective assessment of platelet function in patients undergoing elective resection of glioblastoma multiforme.
    Leal-Noval SR; Casado M; Palomares C; Narros JL; García-Garmendia JL; Escolar G; Cuenca DX; Görlinger K
    Platelets; 2023 Dec; 34(1):2216802. PubMed ID: 37246516
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Performance comparison of the PFA-200 and Anysis-200: Assessment of bleeding risk screening in cardiology patients.
    Piao J; Yoo C; Kim S; Whang YW; Choi CU; Shin S
    Clin Hemorheol Microcirc; 2021; 79(3):445-454. PubMed ID: 34657880
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Hemodialysis shortens long in vitro closure times as measured by the PFA-100.
    Bilgin AU; Karadogan I; Artac M; Kizilors A; Bligin R; Undar L
    Med Sci Monit; 2007 Mar; 13(3):CR141-5. PubMed ID: 17325638
    [TBL] [Abstract][Full Text] [Related]  

  • 15. In Vitro Closure Times (PFA-100) Are Different Between Peritoneal Dialysis and Hemodialysis.
    Gokalp C; Karadag FK; Braunisch MC; Schmaderer C; Gunay E; Kiper HD; Tobu M; Ustün C; Demirci MS; Ozkahya M
    Hamostaseologie; 2020 Dec; 40(5):671-678. PubMed ID: 32717750
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Diagnostic performance of the platelet function analyzer (PFA-100) for the detection of disorders of primary haemostasis in patients with a bleeding history-a systematic review and meta-analysis.
    Karger R; Donner-Banzhoff N; Müller HH; Kretschmer V; Hunink M
    Platelets; 2007 Jun; 18(4):249-60. PubMed ID: 17538845
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Usefulness of the INNOVANCE PFA P2Y test cartridge for the detection of patients with congenital defects of the platelet P2Y₁₂ receptor for adenosine diphosphate.
    Scavone M; Germanovich K; Femia EA; Cattaneo M
    Thromb Res; 2014 Feb; 133(2):254-6. PubMed ID: 24331208
    [TBL] [Abstract][Full Text] [Related]  

  • 18. External quality assessment/proficiency testing and internal quality control for the PFA-100 and PFA-200: an update.
    Favaloro EJ; Bonar R
    Semin Thromb Hemost; 2014 Mar; 40(2):239-53. PubMed ID: 24497116
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Evaluation of platelet aggregation using a point-of-care instrument in retired racing Greyhounds.
    Couto CG; Lara A; Iazbik MC; Brooks MB
    J Vet Intern Med; 2006; 20(2):365-70. PubMed ID: 16594595
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Platelet function testing to assess effectiveness of platelet transfusion therapy.
    Salama ME; Raman S; Drew MJ; Abdel-Raheem M; Mahmood MN
    Transfus Apher Sci; 2004 Apr; 30(2):93-100. PubMed ID: 15062745
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.