These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

111 related articles for article (PubMed ID: 3202347)

  • 1. [Deprogrammation of an artificial pacemaker with the electric scalpel].
    Bussac JJ; Djiane P
    Ann Fr Anesth Reanim; 1988; 7(4):361-2. PubMed ID: 3202347
    [No Abstract]   [Full Text] [Related]  

  • 2. Fibrillation resulting from pacemaker electrodes and electrocautery during surgery.
    Titel JH; el-Etr AA
    Anesthesiology; 1968; 29(4):845-6. PubMed ID: 5662918
    [No Abstract]   [Full Text] [Related]  

  • 3. Cardiac arrest from the use of diathermy during total hip arthroplasty in a patient with an external pacemaker.
    Andrade AJ; Grover ML
    Ann R Coll Surg Engl; 1997 Jan; 79(1):69-70. PubMed ID: 9038499
    [No Abstract]   [Full Text] [Related]  

  • 4. Pacemaker malfunction from urethral electrocautery.
    Smith RB; Wise WS
    JAMA; 1971 Oct; 218(2):256. PubMed ID: 5109967
    [No Abstract]   [Full Text] [Related]  

  • 5. Electrocautery and pacemaker reprogramming.
    Goldberg ME; McSherry RT; O'Connor ME
    Anesth Analg; 1984 May; 63(5):541-2. PubMed ID: 6711850
    [No Abstract]   [Full Text] [Related]  

  • 6. Electrocautery-induced reprogramming of a pacemaker using a precordial magnet.
    Domino KB; Smith TC
    Anesth Analg; 1983 Jun; 62(6):609-12. PubMed ID: 6846885
    [No Abstract]   [Full Text] [Related]  

  • 7. Inadvertent suppression of a fixed rate ventricular pacemaker using a peripheral nerve stimulator.
    O'Flaherty D; Wardill M; Adams AP
    Anaesthesia; 1993 Aug; 48(8):687-9. PubMed ID: 8214459
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Cardiac pacemaker deprogramming by electrocautery. An update].
    Caramella JP; Dodinot B
    Ann Fr Anesth Reanim; 1989; 8(3):290-2. PubMed ID: 2675692
    [No Abstract]   [Full Text] [Related]  

  • 9. Electrocautery-induced pacemaker tachycardia: why does this error continue?
    Rozner MA; Nishman RJ
    Anesthesiology; 2002 Mar; 96(3):773-4; author reply 774. PubMed ID: 11873062
    [No Abstract]   [Full Text] [Related]  

  • 10. Electrocautery-induced pacemaker malfunction during surgery.
    Mangar D; Atlas GM; Kane PB
    Can J Anaesth; 1991 Jul; 38(5):616-8. PubMed ID: 1934215
    [TBL] [Abstract][Full Text] [Related]  

  • 11. An inappropriate recommendation for minimising the risk of pacemaker failure during unipolar diathermy.
    Keller JP; Knickerbocker GG
    Anaesthesia; 1993 Sep; 48(9):825. PubMed ID: 8214511
    [No Abstract]   [Full Text] [Related]  

  • 12. Resetting of DDD pacemaker due to EMI.
    Levine PA
    Pacing Clin Electrophysiol; 1984 Sep; 7(5):925-6. PubMed ID: 6207506
    [No Abstract]   [Full Text] [Related]  

  • 13. [Interaction between electrocautery and a pacemaker].
    Richard JP; Conil JM; Antonini A; Bareille P
    Ann Fr Anesth Reanim; 1986; 5(1):72-3. PubMed ID: 2422991
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Intraoperative pacemaker failure in an infant.
    Bailey AG; Lacey SR
    Can J Anaesth; 1991 Oct; 38(7):912-3. PubMed ID: 1742829
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effect of coagulating and cutting current on a demand pacemaker during transurethral resection of the prostate. A case report.
    Batra YK; Bali IM
    Can Anaesth Soc J; 1978 Jan; 25(1):65-6. PubMed ID: 624109
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [A case of cardiac arrest caused by electrocautery during surgical pacemaker implanting (author's transl)].
    Omote T; Namiki A; Dohi S; Takahashi T; Ohhori K
    Masui; 1981 Oct; 30(10):1126-9. PubMed ID: 7328734
    [No Abstract]   [Full Text] [Related]  

  • 17. Electromagnetic interference (EMI) caused by electrocautery during surgical procedures.
    Moran MD; Kirchhoffer JB; Cassavar DK; Green HL
    Pacing Clin Electrophysiol; 1996 Jun; 19(6):1009. PubMed ID: 8774838
    [No Abstract]   [Full Text] [Related]  

  • 18. [Final arrest of a pacemaker after use of electrocautery].
    Delhumeau A; Ronceray S; Moreau X; Cottineau C; Cavellat M
    Ann Fr Anesth Reanim; 1988; 7(2):162-4. PubMed ID: 3364815
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Diathermy and failure of cardiac pacemakers.
    Goodman NW
    Anaesthesia; 1993 Sep; 48(9):824-5. PubMed ID: 8214510
    [No Abstract]   [Full Text] [Related]  

  • 20. Rapid ventricular pacing due to electrocautery: a case report and review.
    Wilson S; Neustein SN; Camunas J
    Mt Sinai J Med; 2006 Oct; 73(6):880-3. PubMed ID: 17117315
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.