These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

160 related articles for article (PubMed ID: 32025768)

  • 21. Quantification of furanic derivatives in fortified wines by a highly sensitive and ultrafast analytical strategy based on digitally controlled microextraction by packed sorbent combined with ultrahigh pressure liquid chromatography.
    Perestrelo R; Silva CL; Câmara JS
    J Chromatogr A; 2015 Feb; 1381():54-63. PubMed ID: 25618358
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Reduced graphene oxide as an efficient sorbent in microextraction by packed sorbent: Determination of local anesthetics in human plasma and saliva samples utilizing liquid chromatography-tandem mass spectrometry.
    Ahmadi M; Moein MM; Madrakian T; Afkhami A; Bahar S; Abdel-Rehim M
    J Chromatogr B Analyt Technol Biomed Life Sci; 2018 Sep; 1095():177-182. PubMed ID: 30077098
    [TBL] [Abstract][Full Text] [Related]  

  • 23. An analytical strategy for designer benzodiazepines and Z-hypnotics determination in plasma samples using ultra-high performance liquid chromatography/tandem mass spectrometry after microextraction by packed sorbent.
    Ares-Fuentes AM; Lorenzo RA; Fernández P; Carro AM
    J Pharm Biomed Anal; 2021 Feb; 194():113779. PubMed ID: 33279303
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Determination of synthetic hallucinogens in oral fluids by microextraction by packed sorbent and liquid chromatography-tandem mass spectrometry.
    Lesne E; Muñoz-Bartual M; Esteve-Turrillas FA
    Anal Bioanal Chem; 2023 Jul; 415(17):3607-3617. PubMed ID: 37219582
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Determination of AZD6118 in dog plasma samples utilizing microextraction by packed sorbent and liquid chromatography-electrospray ionization tandem mass spectrometry.
    El Beqqali A; Ahmadi M; Abdel-Rehim M
    J Chromatogr B Analyt Technol Biomed Life Sci; 2017 Feb; 1043():20-24. PubMed ID: 27836490
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Effervescence and graphitized multi-walled carbon nanotubes assisted microextraction for natural antioxidants by ultra high performance liquid chromatography with electrochemical detection and quadrupole time-of-flight tandem mass spectrometry.
    Wang SL; Pang XQ; Cao J; Cao W; Xu JJ; Zhu QY; Zhang QY; Peng LQ
    J Chromatogr A; 2015 Oct; 1418():12-20. PubMed ID: 26435313
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Analysis of drugs of abuse in human plasma using microextraction by packed sorbents and ultra-high-performance liquid chromatography.
    Fernández P; González M; Regenjo M; Ares AM; Fernández AM; Lorenzo RA; Carro AM
    J Chromatogr A; 2017 Feb; 1485():8-19. PubMed ID: 28108082
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Modified graphene-silica as a sorbent for in-tube solid-phase microextraction coupled to liquid chromatography-tandem mass spectrometry. Determination of xanthines in coffee beverages.
    Mejía-Carmona K; Lanças FM
    J Chromatogr A; 2020 Jun; 1621():461089. PubMed ID: 32362360
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Graphite-based microextraction by packed sorbent for online extraction of β-blockers from human plasma samples.
    Abuzooda T; Amini A; Abdel-Rehim M
    J Chromatogr B Analyt Technol Biomed Life Sci; 2015 Jun; 992():86-90. PubMed ID: 25958323
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Green analytical toxicology method for determination of synthetic cathinones in oral fluid samples by microextraction by packed sorbent and liquid chromatography-tandem mass spectrometry.
    da Cunha KF; Oliveira KD; Costa JL
    Forensic Toxicol; 2024 Jan; 42(1):18-30. PubMed ID: 37505359
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Polymeric ionic liquid open tubular capillary column for on-line in-tube SPME coupled with UHPLC-MS/MS to determine endocannabinoids in plasma samples.
    Souza ID; Hantao LW; Queiroz MEC
    Anal Chim Acta; 2019 Jan; 1045():108-116. PubMed ID: 30454565
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Determination of the oxidative stress biomarker urinary 8-hydroxy-2'-deoxyguanosine by automated on-line in-tube solid-phase microextraction coupled with liquid chromatography-tandem mass spectrometry.
    Kataoka H; Mizuno K; Oda E; Saito A
    J Chromatogr B Analyt Technol Biomed Life Sci; 2016 Apr; 1019():140-6. PubMed ID: 26349944
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Online biological sample preparation with restricted access hybrid carbon nanotubes for determination of anti-smoking drugs.
    de Faria HD; Silveira AT; do Prado BC; Nacif JLM; Rosa MA; Dos Santos JDR; Santos PCJL; Figueiredo EC; Martins I
    J Chromatogr A; 2022 Apr; 1669():462931. PubMed ID: 35294893
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Analysis of drugs in plasma samples from schizophrenic patients by column-switching liquid chromatography-tandem mass spectrometry with organic-inorganic hybrid cyanopropyl monolithic column.
    Domingues DS; Souza ID; Queiroz ME
    J Chromatogr B Analyt Technol Biomed Life Sci; 2015 Jul; 993-994():26-35. PubMed ID: 25984963
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Column switching UHPLC-MS/MS with restricted access material for the determination of CNS drugs in plasma samples.
    Acquaro VR; Domingues DS; Costa Queiroz ME
    Bioanalysis; 2017 Mar; 9(6):555-568. PubMed ID: 28225304
    [TBL] [Abstract][Full Text] [Related]  

  • 36. A column switching ultrahigh-performance liquid chromatography-tandem mass spectrometry method to determine anandamide and 2-arachidonoylglycerol in plasma samples.
    Marchioni C; de Souza ID; Grecco CF; Crippa JA; Tumas V; Queiroz MEC
    Anal Bioanal Chem; 2017 May; 409(14):3587-3596. PubMed ID: 28337517
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Crosslinked zwitterionic polymeric ionic liquid-functionalized nitinol wires for fiber-in-tube solid-phase microextraction and UHPLC-MS/MS as an amyloid beta peptide binding protein assay in biological fluids.
    Souza ID; Anderson JL; Queiroz MEC
    Anal Chim Acta; 2022 Feb; 1193():339394. PubMed ID: 35058015
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Determination of type A trichothecenes in coix seed by magnetic solid-phase extraction based on magnetic multi-walled carbon nanotubes coupled with ultra-high performance liquid chromatography-tandem mass spectrometry.
    Dong M; Si W; Wang W; Bai B; Nie D; Song W; Zhao Z; Guo Y; Han Z
    Anal Bioanal Chem; 2016 Sep; 408(24):6823-31. PubMed ID: 27475443
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Pipette tip micro-solid phase extraction (octyl-functionalized hybrid silica monolith) and ultra-high-performance liquid chromatography-tandem mass spectrometry to determine cannabidiol and tetrahydrocannabinol in plasma samples.
    Cruz JC; Miranda LFC; Queiroz MEC
    J Sep Sci; 2021 Apr; 44(8):1621-1632. PubMed ID: 33387419
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Determination of urinary levels of leukotriene B(4) using ad highly specific and sensitive methodology based on automatic MEPS combined with UHPLC-PDA analysis.
    Perestrelo R; Silva CL; Câmara JS
    Talanta; 2015 Nov; 144():382-9. PubMed ID: 26452837
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.