These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

116 related articles for article (PubMed ID: 32025873)

  • 21. Farewell to bacteremia caused by endoscopic injection--effectiveness of a new injection catheter with a covered tip.
    Uno Y; Munakata A; Ohtomo Y
    Gastrointest Endosc; 1998 Jun; 47(6):523-5. PubMed ID: 9647379
    [TBL] [Abstract][Full Text] [Related]  

  • 22. [The effect of injection speed and needle gauge on the spread of sensory blockade in spinal anesthesia].
    Schwagmeier R; Schmidt A; Nolte H
    Reg Anaesth; 1990 Sep; 13(7):148-52. PubMed ID: 2236710
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Bacterial contamination of needles used for intravitreal injections: comparison between 27-gauge and 30-gauge needles.
    Tufan HA; Vural A; Gencer B; Kara S; Arikan S; Yuksel E
    Ocul Immunol Inflamm; 2013 Oct; 21(5):366-70. PubMed ID: 23875860
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Effect of water and saliva contamination on the shear bond strength of a new light-cured cyanoacrylate adhesive.
    Cacciafesta V; Sfondrini MF; Gatti S; Klersy C
    Prog Orthod; 2007; 8(1):100-11. PubMed ID: 17364037
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Breakage and deformation characteristics of hypodermic devices under static and dynamic loading.
    Hoff SJ; Sundberg P
    Am J Vet Res; 1999 Mar; 60(3):292-8. PubMed ID: 10188809
    [TBL] [Abstract][Full Text] [Related]  

  • 26. EXPERIMENTAL VISUALIZATION AND QUANTIFICATION OF VITREOUS CONTAMINATION FOLLOWING INTRAVITREAL INJECTIONS.
    Nakashizuka H; Shoji J; Shimada H; Yuzawa M
    Retina; 2016 Oct; 36(10):1882-7. PubMed ID: 27046457
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Is the reuse of needles for insulin injection systems associated with a higher risk of cutaneous complications?
    Schuler G; Pelz K; Kerp L
    Diabetes Res Clin Pract; 1992 Jun; 16(3):209-12. PubMed ID: 1425141
    [TBL] [Abstract][Full Text] [Related]  

  • 28. [Subdural intra-arachnoid spread of local anesthetics. A complication of spinal anesthesia].
    Möllmann M; Holst D; Enk D; Lübbesmeyer H; Deitmer T; Lawin P
    Anaesthesist; 1992 Nov; 41(11):685-8. PubMed ID: 1463156
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Needle contamination in the setting of intravitreal injections.
    Friedman DA; Lindquist TP; Mason JO; McGwin G
    Retina; 2014 May; 34(5):929-34. PubMed ID: 24509487
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Drug contamination from opening glass ampules.
    Zacher AN; Zornow MH; Evans G
    Anesthesiology; 1991 Nov; 75(5):893-5. PubMed ID: 1952213
    [TBL] [Abstract][Full Text] [Related]  

  • 31. High Opening Injection Pressure Is Associated With Needle-Nerve and Needle-Fascia Contact During Femoral Nerve Block.
    Gadsden J; Latmore M; Levine DM; Robinson A
    Reg Anesth Pain Med; 2016; 41(1):50-5. PubMed ID: 26650431
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Problems experienced by older people when opening medicine packaging.
    Philbert D; Notenboom K; Bouvy ML; van Geffen EC
    Int J Pharm Pract; 2014 Jun; 22(3):200-4. PubMed ID: 24025086
    [TBL] [Abstract][Full Text] [Related]  

  • 33. In vitro investigation of cerebrospinal fluid leakage after dural puncture with various spinal needles.
    Holst D; Möllmann M; Ebel C; Hausman R; Wendt M
    Anesth Analg; 1998 Dec; 87(6):1331-5. PubMed ID: 9842822
    [TBL] [Abstract][Full Text] [Related]  

  • 34. The incidence of coring with blunt versus sharp needles.
    Wani T; Wadhwa A; Tobias JD
    J Clin Anesth; 2014 Mar; 26(2):152-4. PubMed ID: 24582180
    [TBL] [Abstract][Full Text] [Related]  

  • 35. The Effectiveness of 0.6% Povidone Iodine Eye Drops in Reducing the Conjunctival Bacterial Load and Needle Contamination in Patients Undergoing Anti-VEGF Intravitreal Injection: A Prospective, Randomized Study.
    Reibaldi M; Avitabile T; Bandello F; Longo A; Bonfiglio V; Russo A; Castellino N; Rejdak R; Nowomiejska K; Toro M; Furino C; Cillino S; Fiore T; Cagini C; Grassi P; Musumeci R; Cocuzza CE; Martinelli M; Fallico M
    J Clin Med; 2019 Jul; 8(7):. PubMed ID: 31337003
    [TBL] [Abstract][Full Text] [Related]  

  • 36. The effect of needle gauge, needle type, and needle orientation on the volume of a drop.
    Tripp GK; Good KL; Motta MJ; Kass PH; Murphy CJ
    Vet Ophthalmol; 2016 Jan; 19(1):38-42. PubMed ID: 25643934
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Glass contamination in parenterally administered medication.
    Preston ST; Hegadoren K
    J Adv Nurs; 2004 Nov; 48(3):266-70. PubMed ID: 15488040
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Influence of hypodermic needle dimensions on subcutaneous injection delivery--a pig study of injection deposition evaluated by CT scanning, histology, and backflow.
    Juul KA; Bengtsson H; Eyving B; Kildegaard J; Lav S; Poulsen M; Serup J; Stallknecht B
    Skin Res Technol; 2012 Nov; 18(4):447-55. PubMed ID: 22233448
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Residual contamination and bioburden after reprocessing of single-use endoscopic ultrasound needles: An ex vivo study.
    Bhatia V; Gupta A; Sharma S; Shandil R; Wadhawan M; Agrawal N; Kumar A
    Dig Endosc; 2017 Mar; 29(2):175-181. PubMed ID: 27634338
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Mechanical aspects of epidural catheter insertion--prevention of catheter buckling by means of a needle hub insert.
    Pinchak AC; Podlipsky HM; Hagen JF
    Anesthesiology; 1983 Dec; 59(6):549-53. PubMed ID: 6650913
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.