These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
125 related articles for article (PubMed ID: 32032955)
1. Cranial flap fixation in sheep using a resorbable bone adhesive. Foley KT; Woodard EJ; Slotkin JR; Mayotte CK; Baldwin AC; Brown MC; Hess BJ J Neurosurg; 2021 Feb; 134(2):621-629. PubMed ID: 32032955 [TBL] [Abstract][Full Text] [Related]
2. Use of adhesive cranial bone flap fixation without hardware to improve mechanical strength, resist cerebrospinal fluid leakage, and maintain anatomical alignment: a laboratory study. Smith TR; Foley KT; Boruah S; Slotkin JR; Woodard E; Lazor JB; Cavaleri C; Brown MC; McDonough B; Hess B; Van Citters DW J Neurosurg; 2023 Aug; 139(2):517-527. PubMed ID: 36681962 [TBL] [Abstract][Full Text] [Related]
3. An Organic Mineral Adhesive Bone Graft: A Preclinical Study. Fiorellini JP; Mojaver S; Kay G; Chang YC; Brown M; Sarmiento H Int J Oral Maxillofac Implants; 2024 Oct; 0(0):1-20. PubMed ID: 39365911 [TBL] [Abstract][Full Text] [Related]
4. Biomechanics of a novel reversibly expandable dynamic craniotomy bone flap fixation plate. Khanna R; Ferrara L; Khanna S J Neurosurg; 2020 Feb; 132(2):560-567. PubMed ID: 30611148 [TBL] [Abstract][Full Text] [Related]
5. In Vitro and In Vivo Evaluation of a Bio-Inspired Adhesive for Bone Fixation. Schlund M; Dartus J; Defrançois S; Ferri J; Delattre J; Blanchemain N; Woisel P; Lyskawa J; Chai F Pharmaceutics; 2023 Apr; 15(4):. PubMed ID: 37111718 [TBL] [Abstract][Full Text] [Related]
6. Biomechanical evaluation of titanium, biodegradable plate and screw, and cyanoacrylate glue fixation systems in craniofacial surgery. Gosain AK; Song L; Corrao MA; Pintar FA Plast Reconstr Surg; 1998 Mar; 101(3):582-91. PubMed ID: 9500375 [TBL] [Abstract][Full Text] [Related]
7. Bioinspired Mineral-Organic Bioresorbable Bone Adhesive. Kirillova A; Kelly C; von Windheim N; Gall K Adv Healthc Mater; 2018 Sep; 7(17):e1800467. PubMed ID: 29938916 [TBL] [Abstract][Full Text] [Related]
8. Resorbable versus titanium plates for orthognathic surgery. Agnihotry A; Fedorowicz Z; Nasser M; Gill KS Cochrane Database Syst Rev; 2017 Oct; 10(10):CD006204. PubMed ID: 28977689 [TBL] [Abstract][Full Text] [Related]
9. Mini titanium plates; hearkening the end of non-rigid cranial bone flap fixation. Junaid M; Bukhari SS; Saeed MA; Rashid MU Pak J Med Sci; 2017; 33(4):915-919. PubMed ID: 29067065 [TBL] [Abstract][Full Text] [Related]
10. Bony healing of large cranial and mandibular defects protected from soft-tissue interposition: A comparative study of spontaneous bone regeneration, osteoconduction, and cancellous autografting in dogs. Lemperle SM; Calhoun CJ; Curran RW; Holmes RE Plast Reconstr Surg; 1998 Mar; 101(3):660-72. PubMed ID: 9500382 [TBL] [Abstract][Full Text] [Related]
11. Consolidation of craniotomy lines after resorbable polylactide and titanium plating: a comparative experimental study in sheep. Peltoniemi HH; Tulamo RM; Pihlajamäki HK; Kallioinen M; Pohjonen T; Törmälä P; Rokkanen PU; Waris T Plast Reconstr Surg; 1998 Jan; 101(1):123-33. PubMed ID: 9427925 [TBL] [Abstract][Full Text] [Related]
12. Biodegradable semirigid plate and miniscrew fixation compared with rigid titanium fixation in experimental calvarial osteotomy. Peltoniemi HH; Tulamo RM; Toivonen T; Hallikainen D; Törmälä P; Waris T J Neurosurg; 1999 May; 90(5):910-7. PubMed ID: 10223458 [TBL] [Abstract][Full Text] [Related]
13. Comparison of 2 kinds of pedicle screws in primary spinal instrumentation: biomechanical and interfacial evaluations in sheep vertebrae in vitro. Liu D; Zhang Y; Lei W; Wang CR; Xie QY; Liao DF; Jiang K; Zhou JS; Zhang B; Pan XM J Spinal Disord Tech; 2014 Apr; 27(2):E72-80. PubMed ID: 23732180 [TBL] [Abstract][Full Text] [Related]
14. A new device for bone cranial flap fixation: Technical note and surgical remarks. A multicentric experience. Piccirilli M; Spena G; Marchese E; Tropeano MP; Santoro A Surg Neurol Int; 2021; 12():74. PubMed ID: 33767878 [TBL] [Abstract][Full Text] [Related]
15. Resorbable versus titanium plates for orthognathic surgery. Fedorowicz Z; Nasser M; Newton JT; Oliver RJ Cochrane Database Syst Rev; 2007 Apr; (2):CD006204. PubMed ID: 17443617 [TBL] [Abstract][Full Text] [Related]
16. [Preliminary application of absorbable fixation system on cranial bone flap reposition and fixation after craniotomy]. Deng Y; Zheng M; Wu J Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2012 Oct; 26(10):1202-5. PubMed ID: 23167103 [TBL] [Abstract][Full Text] [Related]
17. Dynamic Craniotomy With NuCrani Reversibly Expandable Cranial Bone Flap Fixation Plates: A Technical Report. Khanna R; Munz M; Baxter S; Han P Oper Neurosurg (Hagerstown); 2023 Jan; 24(1):94-102. PubMed ID: 36519883 [TBL] [Abstract][Full Text] [Related]
18. Comparison of Mechanical Stabilization of the Mandibular Angulus Fracture Fixation, With Titanium Plates and Screws, Resorbable Plates and Screws, and Bone Adhesives. Cural Ü; Atalay B; Yildirim MS J Craniofac Surg; 2018 Oct; 29(7):1780-1787. PubMed ID: 30113419 [TBL] [Abstract][Full Text] [Related]
19. Resorbable PLLA-PGA plate and screw fixation in pediatric craniofacial surgery: clinical experience in 1883 patients. Eppley BL; Morales L; Wood R; Pensler J; Goldstein J; Havlik RJ; Habal M; Losken A; Williams JK; Burstein F; Rozzelle AA; Sadove AM Plast Reconstr Surg; 2004 Sep; 114(4):850-6; discussion 857. PubMed ID: 15468389 [TBL] [Abstract][Full Text] [Related]
20. Prospective evaluation of patellar tendon graft fixation in anterior cruciate ligament reconstruction comparing composite bioabsorbable and allograft interference screws. Tecklenburg K; Burkart P; Hoser C; Rieger M; Fink C Arthroscopy; 2006 Sep; 22(9):993-9. PubMed ID: 16952730 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]