These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

100 related articles for article (PubMed ID: 3203970)

  • 41. Oxidative biodegradation mechanisms of biaxially strained poly(etherurethane urea) elastomers.
    Schubert MA; Wiggins MJ; Schaefer MP; Hiltner A; Anderson JM
    J Biomed Mater Res; 1995 Mar; 29(3):337-47. PubMed ID: 7542244
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Prenatal developmental safety of functional polyurethanes for cardiovascular implants.
    Gu Y; Sun F; Xie X; Wu X; Zhang Z; Guidoin R; Fu Q; Zhong Y; Zhao C
    J Biomed Mater Res B Appl Biomater; 2016 Apr; 104(3):606-14. PubMed ID: 25953432
    [TBL] [Abstract][Full Text] [Related]  

  • 43. A comparative evaluation of the biostability of a poly (ether urethane) in the intraocular, intramuscular, and subcutaneous environments.
    Christ FR; Buchen SY; Fencil DA; Knight PM; Solomon KD; Apple DJ
    J Biomed Mater Res; 1992 May; 26(5):607-29. PubMed ID: 1512282
    [TBL] [Abstract][Full Text] [Related]  

  • 44. A polyurethane trileaflet cardiac valve prosthesis: in vitro and in vivo studies.
    Wisman CB; Pierce WS; Donachy JH; Pae WE; Myers JL; Prophet GA
    Trans Am Soc Artif Intern Organs; 1982; 28():164-8. PubMed ID: 7164234
    [No Abstract]   [Full Text] [Related]  

  • 45. Analysis and evaluation of a biomedical polycarbonate urethane tested in an in vitro study and an ovine arthroplasty model. Part I: materials selection and evaluation.
    Khan I; Smith N; Jones E; Finch DS; Cameron RE
    Biomaterials; 2005 Feb; 26(6):621-31. PubMed ID: 15282140
    [TBL] [Abstract][Full Text] [Related]  

  • 46. In vitro evaluation of the calcification behavior of polyurethane biomaterials for cardiovascular applications.
    Glasmacher-Seiler B; Reul H; Rau G
    J Long Term Eff Med Implants; 1992; 2(2-3):113-26. PubMed ID: 10171618
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Polyurethanes in medical devices.
    Szycher M; Siciliano AA; Reed AM
    Med Des Mater; 1991 Feb; 1(2):18-25. PubMed ID: 10171592
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Biodegradation of a polyurethane in vitro.
    Phua SK; Castillo E; Anderson JM; Hiltner A
    J Biomed Mater Res; 1987 Feb; 21(2):231-46. PubMed ID: 3818683
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Effect of processing route and acetone pre-treatment on the biostability of pellethane materials used in medical device applications.
    Taylor JE; Laity PR; Freeburn S; Wong SS; Norris K; Khunkamchoo P; Cable M; Andrews G; Johnson AF; Cameron RE
    Biomaterials; 2005 Nov; 26(33):6467-76. PubMed ID: 15935471
    [TBL] [Abstract][Full Text] [Related]  

  • 50. [Surface properties and characteristics of PU-PTHF/MDI/HPC poly(ether)urethane for cardiovascular prosthesis].
    Butnaru M; Dimitriu CD; Macocinschi D
    Rev Med Chir Soc Med Nat Iasi; 2010; 114(4):1246-53. PubMed ID: 21500486
    [TBL] [Abstract][Full Text] [Related]  

  • 51. In vitro and in vivo biodurability of a compliant microporous vascular graft.
    Edwards A; Carson RJ; Szycher M; Bowald S
    J Biomater Appl; 1998 Jul; 13(1):23-45. PubMed ID: 9689578
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Biodegradation of the polyurethane foam covering of breast implants.
    Sinclair TM; Kerrigan CL; Buntic R
    Plast Reconstr Surg; 1993 Nov; 92(6):1003-13; discussion 1014. PubMed ID: 8234496
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Comparative analysis of ventricular assist devices (POLVAD and POLVAD_EXT) based on multiscale FEM model.
    Milenin A; Kopernik M
    Acta Bioeng Biomech; 2011; 13(2):13-23. PubMed ID: 21761807
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Estimation of mechanical heart valve cavitation in a pneumatic ventricular assist device.
    Lee H; Akagawa E; Homma A; Tsukiya T; Tatsumi E; Taenaka Y
    J Artif Organs; 2007; 10(3):181-5. PubMed ID: 17846718
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Theoretical analysis of in vivo macrophage adhesion and foreign body giant cell formation on strained poly(etherurethane urea) elastomers.
    Kao WJ; Hiltner A; Anderson JM; Lodoen GA
    J Biomed Mater Res; 1994 Jul; 28(7):819-29. PubMed ID: 8083250
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Interactions of enzymes and fungi with crosslinked polyurethanes prepared for biomedical applications.
    Jayabalan M; Shunmugakumar N
    Med Prog Technol; 1994; 20(3-4):261-70. PubMed ID: 7877571
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Mechanical mitral prosthesis with a short-term left ventricular assist device.
    Mussa S; Large S; Tsui S; van Doorn C; Jenkins D
    ASAIO J; 2008; 54(4):439-41. PubMed ID: 18645365
    [TBL] [Abstract][Full Text] [Related]  

  • 58. [The effect of glutaraldehyde preparations on the properties of biological heart valve prostheses].
    Vrsanský D
    Bratisl Lek Listy; 1991 Jul; 92(7):352-4. PubMed ID: 1913202
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Prevention of polyurethane valve cusp calcification with covalently attached bisphosphonate diethylamino moieties.
    Alferiev I; Stachelek SJ; Lu Z; Fu AL; Sellaro TL; Connolly JM; Bianco RW; Sacks MS; Levy RJ
    J Biomed Mater Res A; 2003 Aug; 66(2):385-95. PubMed ID: 12889009
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Calcification in cardiovascular implants: degraded cell related phenomena.
    Harasaki H; McMahon J; Richards T; Goldcamp J; Kiraly R; Nose Y
    Trans Am Soc Artif Intern Organs; 1985; 31():489-94. PubMed ID: 3837495
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 5.