BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

133 related articles for article (PubMed ID: 32042356)

  • 1. Defibrillation failure with short ICD charge time: Internal short circuit of a Durata lead.
    Okada A; Shoin W; Shoda M; Tabata H; Kobayashi H; Okano T; Yoshie K; Kato K; Kuwahara K
    J Cardiol Cases; 2020 Feb; 21(2):59-62. PubMed ID: 32042356
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The Canadian experience with Durata and Riata ST Optim defibrillator leads: a report from the Canadian Heart Rhythm Society Device Committee.
    Bennett MT; Ha AC; Exner DV; Tung SK; Parkash R; Connors S; Coutu B; Crystal E; Champagne J; Philippon F; Yee R; Stephenson EA; Nery PB; Essebag V; Sanatani S; Redfearn D; Krahn AD; Healey JS
    Heart Rhythm; 2013 Oct; 10(10):1478-81. PubMed ID: 23973950
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Failure of a novel silicone-polyurethane copolymer (Optim™) to prevent implantable cardioverter-defibrillator lead insulation abrasions.
    Hauser RG; Abdelhadi RH; McGriff DM; Kallinen Retel L
    Europace; 2013 Feb; 15(2):278-83. PubMed ID: 22915789
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Long-term performance and lead failure analysis of the Durata defibrillation lead compared to its previous model, the recalled Riata defibrillation lead.
    Kleemann T; Nonnenmacher F; Strauss M; Kouraki K; Werner N; Fendt A; Zahn R
    J Cardiovasc Electrophysiol; 2019 Oct; 30(10):2012-2019. PubMed ID: 31332876
    [TBL] [Abstract][Full Text] [Related]  

  • 5. High defibrillation threshold with right-sided ICD implantation was resolved by a dual coil lead via persistent left superior vena cava.
    Fujito T; Nagahara D; Tsuzuki T; Kamiyama N; Mochizuki A; Miura T
    J Cardiol Cases; 2022 May; 25(5):262-265. PubMed ID: 35582083
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Internal insulation breaches in an implantable cardioverter-defibrillator lead with redundant conductors.
    Hauser RG; Sengupta J; Schloss EJ; Stanberry LI; Wananu MK; Abdelhadi R
    Heart Rhythm; 2019 Aug; 16(8):1215-1222. PubMed ID: 30772531
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Prospective long-term evaluation of Optim-insulated (Riata ST Optim and Durata) implantable cardioverter-defibrillator leads.
    Cairns JA; Epstein AE; Rickard J; Connolly SJ; Buller C; Wilkoff BL; Pogue J; Themeles E; Healey JS
    Heart Rhythm; 2014 Dec; 11(12):2156-62. PubMed ID: 25131665
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Cable externalization at the proximal portion of the superior vena cava coil in Riata implantable cardioverter defibrillator leads.
    Katsuki T; Furusho H; Kusayama T; Takashima S; Kato T; Murai H; Usui S; Kaneko S; Takamura M
    J Cardiol Cases; 2017 Jan; 15(1):3-5. PubMed ID: 30524571
    [TBL] [Abstract][Full Text] [Related]  

  • 9. User-reported abrasion-related lead failure is more common with durata compared to other implantable cardiac defibrillator leads.
    Shah AD; Hirsh DS; Langberg JJ
    Heart Rhythm; 2015 Dec; 12(12):2376-80. PubMed ID: 26165944
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Differential lead component pulling as a possible mechanism of inside-out abrasion and conductor cable externalization.
    Lau EW
    Pacing Clin Electrophysiol; 2013 Sep; 36(9):1072-89. PubMed ID: 23746039
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Externalized conductors and electrical dysfunction in transvenous ventricular leads: Results of the Cardiac Lead Assessment Study.
    Freedman RA; Curtis AB; Delgado SM; Lee LY
    Heart Rhythm O2; 2022 Apr; 3(2):160-168. PubMed ID: 35496462
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Successful treatment with an implantable cardioverter defibrillator for spontaneous ventricular fibrillation in dilated cardiomyopathy with very high defibrillation thresholds.
    Tamura K; Abe H; Nagatomo T; Nakashima Y
    J UOEH; 2001 Dec; 23(4):363-8. PubMed ID: 11789138
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Systematic fluoroscopic and electrical assessment of implantable cardioverter-defibrillator patients implanted with silicone-polyurethane copolymer (Optim™) coated leads.
    Forleo GB; Di Biase L; Panattoni G; Politano A; Magliano G; Santini L; Natale A; Romeo F
    Europace; 2014 Feb; 16(2):265-70. PubMed ID: 24042736
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Prospective long-term follow-up of silicone-polyurethane-insulated implantable cardioverter-defibrillator leads.
    Cairns JA; Healey JS; Epstein AE; Themeles E; Balasubramanian K; Connolly SJ
    Heart Rhythm O2; 2022 Feb; 3(1):57-64. PubMed ID: 35243436
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Failure of implantable cardioverter-defibrillator leads: a matter of lead size?
    Rordorf R; Poggio L; Savastano S; Vicentini A; Petracci B; Chieffo E; Klersy C; Landolina M
    Heart Rhythm; 2013 Feb; 10(2):184-90. PubMed ID: 23063430
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Sudden and Fatal Malfunction of a Durata Defibrillator Lead due to External Insulation Failure.
    Shah AD; Hirsh DS; Langberg JJ
    Pacing Clin Electrophysiol; 2016 Jan; 39(1):101-4. PubMed ID: 26293817
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Failure-free survival of the Durata defibrillator lead.
    Liu J; Patel D; Rattan R; Brumberg G; Saini A; Vaghasia N; Bazaz R; Adelstein E; Jain S; Saba S
    Europace; 2013 Jul; 15(7):1002-6. PubMed ID: 23376976
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Implantable intravascular defibrillator: defibrillation thresholds of an intravascular cardioverter-defibrillator compared with those of a conventional ICD in humans.
    Neuzil P; Reddy VY; Merkely B; Geller L; Molnar L; Bednarek J; Bartus K; Richey M; Bsee TJ; Sanders WE
    Heart Rhythm; 2014 Feb; 11(2):210-5. PubMed ID: 24144885
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Performance of the Durata implantable cardioverter defibrillator lead: results of an independent multicenter study.
    Rordorf R; Taravelli E; Forleo GB; Giannola G; Calzolari V; Tadeo G; Rossi S; Vicentini A; Curnis A; Serra P; Santamaria M; Calò L
    J Cardiovasc Med (Hagerstown); 2019 Oct; 20(10):676-681. PubMed ID: 31343450
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Pulse Generator Exchange Does Not Accelerate the Rate of Electrical Failure in a Recalled Small Caliber ICD Lead.
    Lovelock JD; Premkumar A; Levy MR; Mengistu A; Hoskins MH; El-Chami MF; Lloyd MS; Leon AR; Langberg JJ; Delurgio DB
    Pacing Clin Electrophysiol; 2015 Dec; 38(12):1434-8. PubMed ID: 26285670
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.