These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
259 related articles for article (PubMed ID: 3204496)
1. The use of silicone/polyurethane graft polymers as a means of eliminating surface cracking of polyurethane prostheses. Pinchuk L; Martin JB; Esquivel MC; MacGregor DC J Biomater Appl; 1988 Oct; 3(2):260-96. PubMed ID: 3204496 [TBL] [Abstract][Full Text] [Related]
3. In vivo biostability of shore 55D polyether polyurethanes with and without fluoropolymer surface modifying endgroups. Ward R; Anderson J; McVenes R; Stokes K J Biomed Mater Res A; 2006 Dec; 79(4):836-45. PubMed ID: 16886224 [TBL] [Abstract][Full Text] [Related]
4. Biomedical applications of polyurethanes: implications of failure mechanisms. Phillips RE; Smith MC; Thoma RJ J Biomater Appl; 1988 Oct; 3(2):207-27. PubMed ID: 3060586 [TBL] [Abstract][Full Text] [Related]
5. Long-term in vivo biostability of poly(dimethylsiloxane)/poly(hexamethylene oxide) mixed macrodiol-based polyurethane elastomers. Simmons A; Hyvarinen J; Odell RA; Martin DJ; Gunatillake PA; Noble KR; Poole-Warren LA Biomaterials; 2004 Sep; 25(20):4887-900. PubMed ID: 15109849 [TBL] [Abstract][Full Text] [Related]
6. In vivo biostability of polyether polyurethanes with polyethylene oxide surface-modifying end groups; resistance to biologic oxidation and stress cracking. Ebert M; Ward B; Anderson J; McVenes R; Stokes K J Biomed Mater Res A; 2005 Oct; 75(1):175-84. PubMed ID: 16041797 [TBL] [Abstract][Full Text] [Related]
7. In vivo evaluation of porous versus skinned polyurethane-polydimethylsiloxane small diameter vascular grafts. Okoshi T; Goddard M; Galletti PM; Soldani G ASAIO Trans; 1991; 37(3):M480-1. PubMed ID: 1751244 [TBL] [Abstract][Full Text] [Related]
8. Blood compatibility of PEO grafted polyurethane and HEMA/styrene block copolymer surfaces. Nojiri C; Okano T; Jacobs HA; Park KD; Mohammad SF; Olsen DB; Kim SW J Biomed Mater Res; 1990 Sep; 24(9):1151-71. PubMed ID: 2211743 [TBL] [Abstract][Full Text] [Related]
9. The composite Corethane/Dacron vascular prosthesis. Canine in vivo evaluation of 4 mm diameter grafts with 1 year follow-up. Wilson GJ; MacGregor DC; Klement P; Dereume JP; Weber BA; Binnington AG; Pinchuk L ASAIO Trans; 1991; 37(3):M475-6. PubMed ID: 1836338 [TBL] [Abstract][Full Text] [Related]
11. In vivo evaluation of polyurethanes based on novel macrodiols and MDI. Brandwood A; Meijs GF; Gunatillake PA; Noble KR; Schindhelm K; Rizzardo E J Biomater Sci Polym Ed; 1994; 6(1):41-54. PubMed ID: 7947472 [TBL] [Abstract][Full Text] [Related]
12. In vivo biostability of a poly(carbonate-urea)urethane graft. Seifalian AM; Salacinski HJ; Tiwari A; Edwards A; Bowald S; Hamilton G Biomaterials; 2003 Jun; 24(14):2549-57. PubMed ID: 12695082 [TBL] [Abstract][Full Text] [Related]
13. In vitro and in vivo biodurability of a compliant microporous vascular graft. Edwards A; Carson RJ; Szycher M; Bowald S J Biomater Appl; 1998 Jul; 13(1):23-45. PubMed ID: 9689578 [TBL] [Abstract][Full Text] [Related]
14. Use of synthetic polymers for biomedical application. Guerin P Pacing Clin Electrophysiol; 1983 Mar; 6(2 Pt 2):449-53. PubMed ID: 6189091 [TBL] [Abstract][Full Text] [Related]
15. Biostability of a non-ether polyurethane. Capone CD J Biomater Appl; 1992 Oct; 7(2):108-29. PubMed ID: 1447699 [TBL] [Abstract][Full Text] [Related]
17. Factors and interactions affecting the performance of polyurethane elastomers in medical devices. Coury AJ; Slaikeu PC; Cahalan PT; Stokes KB; Hobot CM J Biomater Appl; 1988 Oct; 3(2):130-79. PubMed ID: 3060584 [TBL] [Abstract][Full Text] [Related]
18. Biostability and macrophage-mediated foreign body reaction of silicone-modified polyurethanes. Christenson EM; Dadsetan M; Hiltner A J Biomed Mater Res A; 2005 Aug; 74(2):141-55. PubMed ID: 16201029 [TBL] [Abstract][Full Text] [Related]