These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
145 related articles for article (PubMed ID: 32059234)
1. Arthrodesis of the equine proximal interphalangeal joint: a biomechanical comparison of 2 different LCP systems. Vidović A; Jansen D; Schwan S; Goldstein A; Ludtka C; Brehm W Tierarztl Prax Ausg G Grosstiere Nutztiere; 2020 Feb; 48(1):25-34. PubMed ID: 32059234 [TBL] [Abstract][Full Text] [Related]
2. A mechanical comparison of equine proximal interphalangeal joint arthrodesis techniques: an axial locking compression plate and two abaxial transarticular cortical screws versus an axial dynamic compression plate and two abaxial transarticular cortical screws. Sod GA; Riggs LM; Mitchell CF; Martin GS Vet Surg; 2011 Jul; 40(5):571-8. PubMed ID: 21521241 [TBL] [Abstract][Full Text] [Related]
3. In vitro biomechanical comparison of a 4.5 mm narrow locking compression plate construct versus a 4.5 mm limited contact dynamic compression plate construct for arthrodesis of the equine proximal interphalangeal joint. Ahern BJ; Showalter BL; Elliott DM; Richardson DW; Getman LM Vet Surg; 2013 Apr; 42(3):335-9. PubMed ID: 23445267 [TBL] [Abstract][Full Text] [Related]
4. Comparison of a 3-hole 4.5-mm Dynamic Compression Plate and a 7-hole 5.5-mm Y Locking Compression Plate for Arthrodesis of the Proximal Interphalangeal Joint in Horses-an Ex Vivo Biomechanical Study. Latorre CAS; de Souza AF; Ramos PAR; Nóbrega FS; van de Graaf GMM; Pereira CAM; Ferrigno CRA; Hendrickson DA; De Zoppa ALDV J Equine Vet Sci; 2020 Nov; 94():103252. PubMed ID: 33077103 [TBL] [Abstract][Full Text] [Related]
5. In vitro biomechanical comparison of equine proximal interphalangeal joint arthrodesis techniques: prototype equine spoon plate versus axially positioned dynamic compression plate and two abaxial transarticular cortical screws inserted in lag fashion. Sod GA; Mitchell CF; Hubert JD; Martin GS; Gill MS Vet Surg; 2007 Dec; 36(8):792-9. PubMed ID: 18067621 [TBL] [Abstract][Full Text] [Related]
6. Does the proximal screw type affect stress and strain in pastern arthrodesis with locking plate in horses? de Souza AF; Pereira CAM; Fürst A; Kümmerle JM; De Zoppa ALDV Res Vet Sci; 2024 Oct; 178():105378. PubMed ID: 39137606 [TBL] [Abstract][Full Text] [Related]
7. In vitro biomechanical comparison of a 5-hole 4.5 mm locking compression plate and 5-hole 4.5 mm dynamic compression plate for equine proximal interphalangeal joint arthrodesis. Seo JP; Yamaga T; Tsuzuki N; Yamada K; Haneda S; Furuoka H; Sasaki N Vet Surg; 2014 Jul; 43(5):606-11. PubMed ID: 24512440 [TBL] [Abstract][Full Text] [Related]
8. Arthrodesis of the equine proximal interphalangeal joint: a biomechanical comparison of two 7-hole 3.5-mm broad and two 5-hole 4.5-mm narrow dynamic compression plates. Watt BC; Edwards RB; Markel MD; McCabe R; Wilson DG Vet Surg; 2002; 31(1):85-93. PubMed ID: 11778172 [TBL] [Abstract][Full Text] [Related]
9. Arthrodesis of the equine proximal interphalangeal joint: a biomechanical comparison of 3-hole 4.5 mm locking compression plate and 3-hole 4.5 mm narrow dynamic compression plate, with two transarticular 5.5 mm cortex screws. Zoppa AL; Santoni B; Puttlitz CM; Cochran K; Hendrickson DA Vet Surg; 2011 Feb; 40(2):253-9. PubMed ID: 21244444 [TBL] [Abstract][Full Text] [Related]
10. An in vitro biomechanical comparison of equine proximal interphalangeal joint arthrodesis techniques: an axial positioned dynamic compression plate and two abaxial transarticular cortical screws inserted in lag fashion versus three parallel transarticular cortical screws inserted in lag fashion. Sod GA; Riggs LM; Mitchell CF; Hubert JD; Martin GS Vet Surg; 2010 Jan; 39(1):83-90. PubMed ID: 20210950 [TBL] [Abstract][Full Text] [Related]
11. Arthrodesis of the equine proximal interphalangeal joint: a biomechanical comparison of three 4.5-mm and two 5.5-mm cortical screws. Watt BC; Edwards RB; Markel MD; McCabe R; Wilson DG Vet Surg; 2001; 30(3):287-94. PubMed ID: 11340561 [TBL] [Abstract][Full Text] [Related]
12. The influence of a tension band fixation as an adjunct for arthrodesis of the metacarpophalangeal joint in the horse. Kadic LIM; Rademacher N; Liu CC; Leise BS; McCauley CT; Riggs LM Vet Surg; 2024 Jan; 53(1):194-203. PubMed ID: 37752808 [TBL] [Abstract][Full Text] [Related]
13. Minimally Invasive Arthrodesis of the Equine Proximal Interphalangeal Joint: A Biomechanical Comparison of Three 5.5-mm Cortical Screws Inserted in Lag Fashion and Two 7.0-mm Headless Cannulated Dual-Pitch Compression Screws. Rumpel AS; De Carvalho AL; Vassoler JM; Schmidt ML; Mertz CC; Rozo CAC; Campos JK; Alievi MM Vet Comp Orthop Traumatol; 2023 Jul; 36(4):184-192. PubMed ID: 36758617 [TBL] [Abstract][Full Text] [Related]
14. Comparison of limited-contact dynamic compression plate and locking compression plate constructs for proximal interphalangeal joint arthrodesis in the horse. Rocconi RA; Carmalt JL; Sampson SN; Elder SH; Gilbert EE Can Vet J; 2015 Jun; 56(6):615-9. PubMed ID: 26028685 [TBL] [Abstract][Full Text] [Related]
15. An in vitro biomechanical comparison of equine proximal interphalangeal joint arthrodesis techniques: two parallel transarticular headless tapered variable pitch screws versus two parallel transarticular AO cortical bone screws inserted in lag fashion. Gudehus T; Sod GA; Riggs LM; Mitchell CF; Martin GS Vet Surg; 2011 Apr; 40(3):261-5. PubMed ID: 21361995 [TBL] [Abstract][Full Text] [Related]
16. An in vitro biomechanical comparison of a locking compression plate fixation and kerf cut cylinder fixation for ventral arthrodesis of the fourth and the fifth equine cervical vertebrae. Reardon RJ; Bailey R; Walmsley JP; Heller J; Lischer C Vet Surg; 2010 Dec; 39(8):980-90. PubMed ID: 20880140 [TBL] [Abstract][Full Text] [Related]
17. Arthrodesis of the equine proximal interphalangeal joint: a mechanical comparison of 2 parallel 5.5 mm cortical screws and 3 parallel 5.5 mm cortical screws. Read EK; Chandler D; Wilson DG Vet Surg; 2005; 34(2):142-7. PubMed ID: 15860105 [TBL] [Abstract][Full Text] [Related]
18. A locking compression plate versus the gold-standard non-locking plate with lag screw for first metatarsophalangeal fusion: A biomechanical comparison. Mandell D; Karbassi J; Zhou H; Burroughs B; Aurigemma P; Patel AR Foot (Edinb); 2018 Mar; 34():69-73. PubMed ID: 29353123 [TBL] [Abstract][Full Text] [Related]
19. Arthrodesis of the equine proximal interphalangeal joint: a biomechanical comparison of two parallel headless, tapered, variable-pitched, titanium compression screws and two parallel 5.5 mm stainless-steel cortical screws. Wolker RR; Carmalt JL; Wilson DG Vet Surg; 2009 Oct; 38(7):861-7. PubMed ID: 19781029 [TBL] [Abstract][Full Text] [Related]
20. Clinical use of the locking compression plate (LCP) in horses: a retrospective study of 31 cases (2004-2006). Levine DG; Richardson DW Equine Vet J; 2007 Sep; 39(5):401-6. PubMed ID: 17910263 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]