121 related articles for article (PubMed ID: 3206194)
1. Effect of electrode temperature on orthostatic changes in forefoot transcutaneous oxygen tension (tc-PO2).
Aabech J; Jensen FB; Utzon NP; Eickhoff JH; Paaske WP
Scand J Clin Lab Invest; 1988 Sep; 48(5):475-80. PubMed ID: 3206194
[TBL] [Abstract][Full Text] [Related]
2. Transcutaneous carbon dioxide and oxygen tension measured at different temperatures in healthy adults.
Wimberley PD; Grønlund Pedersen K; Olsson J; Siggaard-Andersen O
Clin Chem; 1985 Oct; 31(10):1611-5. PubMed ID: 3930089
[TBL] [Abstract][Full Text] [Related]
3. Transcutaneous pO2 electrode.
Vesterager P
Scand J Clin Lab Invest Suppl; 1977; 146():27-30. PubMed ID: 834956
[TBL] [Abstract][Full Text] [Related]
4. Transcutaneous oxygen pressure measured at two different electrode core temperatures in healthy volunteers and patients with arterial occlusive disease.
Creutzig A; Dau D; Caspary L; Alexander K
Int J Microcirc Clin Exp; 1987; 5(4):373-80. PubMed ID: 3557822
[TBL] [Abstract][Full Text] [Related]
5. Blood flow rate, temperature, oxygen tension and consumption in the skin of adults measured by a heated microcathode oxygen electrode.
Jaszczak P
Dan Med Bull; 1988 Aug; 35(4):322-34. PubMed ID: 3048920
[TBL] [Abstract][Full Text] [Related]
6. Transcutaneous and capillary pCO2 and pO2 measurements in healthy adults.
Wimberley PD; Pedersen KG; Thode J; Fogh-Andersen N; Sørensen AM; Siggaard-Andersen O
Clin Chem; 1983 Aug; 29(8):1471-3. PubMed ID: 6409449
[TBL] [Abstract][Full Text] [Related]
7. Evaluation of a transcutaneous oxygen and carbon dioxide monitor in a neonatal intensive care department.
Wimberley PD; Frederiksen PS; Witt-Hansen J; Melberg SG; Friis-Hansen B
Acta Paediatr Scand; 1985 May; 74(3):352-9. PubMed ID: 3923776
[TBL] [Abstract][Full Text] [Related]
8. Simultaneous transcutaneous carbon dioxide and transcutaneous oxygen monitoring in neonatal intensive care.
Löfgren O; Andersson D
J Perinat Med; 1983; 11(1):51-6. PubMed ID: 6405025
[TBL] [Abstract][Full Text] [Related]
9. Transcutaneous oxygen tension during prostacyclin infusion in distal limb ischaemia.
Lepäntalo M; Hietaniemi K
Ann Chir Gynaecol; 1990; 79(1):58-60. PubMed ID: 2113375
[TBL] [Abstract][Full Text] [Related]
10. Effect of Transcutaneous Electrode Temperature on Accuracy and Precision of Carbon Dioxide and Oxygen Measurements in the Preterm Infants.
Jakubowicz JF; Bai S; Matlock DN; Jones ML; Hu Z; Proffitt B; Courtney SE
Respir Care; 2018 Jul; 63(7):900-906. PubMed ID: 29717098
[TBL] [Abstract][Full Text] [Related]
11. Oxygen tension and consumption measured by a tc-PO2 electrode on heated skin before and after epidermal stripping.
Jaszczak P; Sejrsen P
Acta Anaesthesiol Scand; 1987 Jul; 31(5):362-9. PubMed ID: 3630579
[TBL] [Abstract][Full Text] [Related]
12. Estimation of blood flow in transcutaneous PO2 measurements.
Jaszczak P; Poulsen J
Acta Anaesthesiol Scand; 1983 Apr; 27(2):174-80. PubMed ID: 6837253
[TBL] [Abstract][Full Text] [Related]
13. Effects of the transcutaneous electrode temperature on the accuracy of transcutaneous carbon dioxide tension.
Sørensen LC; Brage-Andersen L; Greisen G
Scand J Clin Lab Invest; 2011 Nov; 71(7):548-52. PubMed ID: 21732731
[TBL] [Abstract][Full Text] [Related]
14. Dependence of transcutaneous O2 partial pressure on cutaneous blood flow.
Steinacker JM; Spittelmeister W
J Appl Physiol (1985); 1988 Jan; 64(1):21-5. PubMed ID: 3356639
[TBL] [Abstract][Full Text] [Related]
15. International Federation of Clinical Chemistry (IFCC). Scientific Division. Committee on pH, Blood Gases and Electrolytes. Guidelines for transcutaneous PO2 and PCO2 measurement.
Winberley PD; Burnett RW; Covington AK; Maas AH; Mueller-Plathe O; Siggaard-Andersen O; Weisberg HF; Zijlstra WG
Ann Biol Clin (Paris); 1990; 48(1):39-43. PubMed ID: 2306025
[TBL] [Abstract][Full Text] [Related]
16. Transcutaneous PCO2 during labor--a comparison with fetal blood gas analysis and transcutaneous PO2.
Braems G; Künzel W; Lang U
Eur J Obstet Gynecol Reprod Biol; 1993 Dec; 52(2):81-8. PubMed ID: 8157146
[TBL] [Abstract][Full Text] [Related]
17. Effects of the electrode temperature of a new monitor, TCM4, on the measurement of transcutaneous oxygen and carbon dioxide tension.
Nishiyama T; Nakamura S; Yamashita K
J Anesth; 2006; 20(4):331-4. PubMed ID: 17072703
[TBL] [Abstract][Full Text] [Related]
18. Transcutaneous pO2 imaging during tourniquet-induced forearm ischemia using planar optical oxygen sensors.
Babilas P; Lamby P; Prantl L; Schreml S; Jung EM; Liebsch G; Wolfbeis OS; Landthaler M; Szeimies RM; Abels C
Skin Res Technol; 2008 Aug; 14(3):304-11. PubMed ID: 19159376
[TBL] [Abstract][Full Text] [Related]
19. Is transcutaneous oxygen tension independent of variations in blood flow and in arterial blood pressure?
Eickhoff JH; Jacobsen E
Biotelem Patient Monit; 1982; 9(3):175-84. PubMed ID: 7159703
[TBL] [Abstract][Full Text] [Related]
20. Measurement of heated skin O2 diffusion conductance and PO2 sensor induced O2 gradient.
Eberhard P; Severinghaus JW
Acta Anaesthesiol Scand Suppl; 1978; 68():1-3. PubMed ID: 279189
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]