These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

205 related articles for article (PubMed ID: 32063534)

  • 41. Effect of different materials and undercut on the removal force and stress distribution in circumferential clasps during direct retainer action in removable partial dentures.
    Tribst JPM; Dal Piva AMO; Borges ALS; Araújo RM; da Silva JMF; Bottino MA; Kleverlaan CJ; de Jager N
    Dent Mater; 2020 Feb; 36(2):179-186. PubMed ID: 31791736
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Effects of 3 kinds of processing techniques on the fitness of metal clasp.
    Yin X; Zhou H; Yan F; Wu X; Wu G; Pang D
    Zhong Nan Da Xue Xue Bao Yi Xue Ban; 2021 Oct; 46(10):1122-1128. PubMed ID: 34911843
    [TBL] [Abstract][Full Text] [Related]  

  • 43. A comparison of various removable partial denture clasp materials and fabrication procedure for placing clasps on canine and premolar teeth.
    VandenBrink JP; Wolfaardt JF; Faulkner MG
    J Prosthet Dent; 1993 Aug; 70(2):180-8. PubMed ID: 8103801
    [TBL] [Abstract][Full Text] [Related]  

  • 44. An in vitro comparison of retentive force and deformation of acetal resin and cobalt-chromium clasps.
    Arda T; Arikan A
    J Prosthet Dent; 2005 Sep; 94(3):267-74. PubMed ID: 16126079
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Finite element stress analysis and fatigue behavior of cast circumferential clasps.
    Sandu L; Faur N; Bortun C
    J Prosthet Dent; 2007 Jan; 97(1):39-44. PubMed ID: 17280890
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Stress distribution in retentive arms of combination clasps used on premolars.
    Sandu L; Topala F; Porojan S
    J Appl Biomater Biomech; 2010; 8(2):76-81. PubMed ID: 20740469
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Effect of friction coefficient on Akers clasp retention.
    Sato Y; Abe Y; Yuasa Y; Akagawa Y
    J Prosthet Dent; 1997 Jul; 78(1):22-7. PubMed ID: 9237142
    [TBL] [Abstract][Full Text] [Related]  

  • 48. An analytical model to design circumferential clasps for laser-sintered removable partial dentures.
    Alsheghri AA; Alageel O; Caron E; Ciobanu O; Tamimi F; Song J
    Dent Mater; 2018 Oct; 34(10):1474-1482. PubMed ID: 29937332
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Influence of thickness and undercut of thermoplastic resin clasps on retentive force.
    Osada H; Shimpo H; Hayakawa T; Ohkubo C
    Dent Mater J; 2013; 32(3):381-9. PubMed ID: 23718997
    [TBL] [Abstract][Full Text] [Related]  

  • 50. [Studies on the retentive force of clasps. 1. An effect of the material and technician].
    Takahashi T; Sano Y; Hiraoka M; Kadoi S; Nakai M; Tanaka S; Saitoh M; Kanazawa T
    Nihon Hotetsu Shika Gakkai Zasshi; 1989 Jun; 33(3):589-95. PubMed ID: 2489719
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Influence of block-out on retentive force of thermoplastic resin clasps: an in vitro experimental and finite element analysis.
    Yamazaki T; Murakami N; Suzuki S; Handa K; Yatabe M; Takahashi H; Wakabayashi N
    J Prosthodont Res; 2019 Jul; 63(3):303-308. PubMed ID: 30704930
    [TBL] [Abstract][Full Text] [Related]  

  • 52. New Clasp Assembly for Distal Extension Removable Partial Dentures: The Reverse RPA Clasp.
    Hakkoum MA
    J Prosthodont; 2016 Jul; 25(5):411-3. PubMed ID: 26102601
    [TBL] [Abstract][Full Text] [Related]  

  • 53. [A three-dimensional finite element analysis on relationship between abutment undercut and retentive arm width of cast cobalt-chromium three-arm clasp].
    Wang SY; Zhang ZT; Bai BJ
    Zhonghua Kou Qiang Yi Xue Za Zhi; 2007 May; 42(5):276-9. PubMed ID: 17686278
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Different Undercut Depths Influence on Fatigue Behavior and Retentive Force of Removable Partial Denture Clasp Materials: A Systematic Review.
    Zheng J; Aarts JM; Ma S; Waddell JN; Choi JJE
    J Prosthodont; 2023 Feb; 32(2):108-115. PubMed ID: 35405767
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Retentive forces and fatigue resistance of thermoplastic resin clasps.
    Tannous F; Steiner M; Shahin R; Kern M
    Dent Mater; 2012 Mar; 28(3):273-8. PubMed ID: 22130464
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Internal porosity of cast titanium removable partial dentures: influence of sprue direction and diameter on porosity in simplified circumferential clasps.
    Baltag I; Watanabe K; Miyakawa O
    Dent Mater; 2005 Jun; 21(6):530-7. PubMed ID: 15904695
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Cobalt-chromium-titanium alloy for removable partial dentures.
    Iwama CY; Preston JD
    Int J Prosthodont; 1997; 10(4):309-17. PubMed ID: 9484040
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Maximum dislodging forces of mandibular implant-assisted removable partial dentures: in vitro assessment.
    Gharehchahi J; Asadzadeh N; Mirmortazavi A; Shakeri MT
    J Prosthodont; 2013 Oct; 22(7):543-549. PubMed ID: 23551954
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Fatigue resistance of titanium-nickel alloy cast clasps.
    Kotake M; Wakabayashi N; Ai M; Yoneyama T; Hamanaka H
    Int J Prosthodont; 1997; 10(6):547-52. PubMed ID: 9495176
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Effects of long-term simulated RPD clasp attachment/detachment on retention loss and wear for two clasp types and three abutment material surfaces.
    Helal MA; Baraka OA; Sanad ME; Ludwig K; Kern M
    J Prosthodont; 2012 Jul; 21(5):370-7. PubMed ID: 22443158
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 11.