These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

166 related articles for article (PubMed ID: 32063537)

  • 21. Corrosion behavior of Ti-39Nb alloy for dentistry.
    Fojt J; Joska L; Malek J; Sefl V
    Mater Sci Eng C Mater Biol Appl; 2015 Nov; 56():532-7. PubMed ID: 26249624
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Static immersion and irritation tests of dental metal-ceramic alloys.
    Ardlin BI; Dahl JE; Tibballs JE
    Eur J Oral Sci; 2005 Feb; 113(1):83-9. PubMed ID: 15693834
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Galvanic corrosion behavior of orthodontic archwire alloys coupled to bracket alloys.
    Iijima M; Endo K; Yuasa T; Ohno H; Hayashi K; Kakizaki M; Mizoguchi I
    Angle Orthod; 2006 Jul; 76(4):705-11. PubMed ID: 16808581
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Metallic ions released from stainless steel, nickel-free, and titanium orthodontic alloys: toxicity and DNA damage.
    Ortiz AJ; Fernández E; Vicente A; Calvo JL; Ortiz C
    Am J Orthod Dentofacial Orthop; 2011 Sep; 140(3):e115-22. PubMed ID: 21889059
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Corrosion behavior and surface characterization of Ti-20Cr alloy in a solution containing fluoride.
    Takemoto S; Hattori M; Yoshinari M; Kawada E; Asami K; Oda Y
    Dent Mater J; 2004 Sep; 23(3):379-86. PubMed ID: 15510869
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Effect of Cr and Cu addition on corrosion behavior of Ni-Ti alloys.
    Iijima M; Endo K; Ohno H; Mizoguchi I
    Dent Mater J; 1998 Mar; 17(1):31-40. PubMed ID: 9663060
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Development of novel Ti-Mo-Mn alloys for biomedical applications.
    Lourenço ML; Cardoso GC; Sousa KDSJ; Donato TAG; Pontes FML; Grandini CR
    Sci Rep; 2020 Apr; 10(1):6298. PubMed ID: 32286366
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Production, microstructural characterization and mechanical properties of as-cast Ti-10Mo-xNb alloys.
    Gabriel SB; Nunes CA; Soares Gde A
    Artif Organs; 2008 Apr; 32(4):299-304. PubMed ID: 18370944
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Evaluation of metal ion release from Ti6Al4V and Co-Cr-Mo casting alloys: in vivo and in vitro study.
    El Sawy AA; Shaarawy MA
    J Prosthodont; 2014 Feb; 23(2):89-97. PubMed ID: 23755902
    [TBL] [Abstract][Full Text] [Related]  

  • 30. A new titanium based alloy Ti-27Nb-13Zr produced by powder metallurgy with biomimetic coating for use as a biomaterial.
    Mendes MW; Ágreda CG; Bressiani AH; Bressiani JC
    Mater Sci Eng C Mater Biol Appl; 2016 Jun; 63():671-7. PubMed ID: 27040264
    [TBL] [Abstract][Full Text] [Related]  

  • 31. In vitro biocompatibility, mechanical properties, and corrosion resistance of Ti-Zr-Nb-Ta-Pd and Ti-Sn-Nb-Ta-Pd alloys.
    Ito A; Okazaki Y; Tateishi T; Ito Y
    J Biomed Mater Res; 1995 Jul; 29(7):893-9. PubMed ID: 7593029
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Electrochemical corrosion behavior and elasticity properties of Ti-6Al-xFe alloys for biomedical applications.
    Lu J; Zhao Y; Niu H; Zhang Y; Du Y; Zhang W; Huo W
    Mater Sci Eng C Mater Biol Appl; 2016 May; 62():36-44. PubMed ID: 26952395
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Elemental release from CoCr and NiCr alloys containing palladium.
    Beck KA; Sarantopoulos DM; Kawashima I; Berzins DW
    J Prosthodont; 2012 Feb; 21(2):88-93. PubMed ID: 22380645
    [TBL] [Abstract][Full Text] [Related]  

  • 34. The effects of proteins on metallic corrosion.
    Clark GC; Williams DF
    J Biomed Mater Res; 1982 Mar; 16(2):125-34. PubMed ID: 7061531
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Effects of alloying elements (Mn, Co, Al, W, Sn, B, C and S) on biodegradability and in vitro biocompatibility of pure iron.
    Liu B; Zheng YF
    Acta Biomater; 2011 Mar; 7(3):1407-20. PubMed ID: 21056126
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Effect of surface area ratios and bacteria on electrochemical behavior of galvanically coupled titanium.
    Koh I; Oshida Y; Andres CJ; Gregory RL
    Int J Prosthodont; 2008; 21(5):433-6. PubMed ID: 18950067
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Corrosion behavior of pure titanium and titanium alloys in fluoride-containing solutions.
    Nakagawa M; Matsuya S; Udoh K
    Dent Mater J; 2001 Dec; 20(4):305-14. PubMed ID: 11915624
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Fretting corrosion in orthopaedic alloys.
    Cook SD; Gianoli GJ; Clemow AJ; Haddad RJ
    Biomater Med Devices Artif Organs; 1983-1984; 11(4):281-92. PubMed ID: 6679798
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Effect of element concentration on nickel release from dental alloys using a novel ion beam method.
    Jones SB; Taylor RL; Colligon JS; Johnson D
    Dent Mater; 2010 Mar; 26(3):249-56. PubMed ID: 20005564
    [TBL] [Abstract][Full Text] [Related]  

  • 40. [Influence of different NaCl concentration on passive behavior of Cr alloy in vitro].
    Su RG; Wang SF; Zhang XF; Qu PL
    Zhonghua Kou Qiang Yi Xue Za Zhi; 2010 Jan; 45(1):49-51. PubMed ID: 20368042
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.