187 related articles for article (PubMed ID: 32067906)
1. The combined use of end-tidal carbon dioxide and alveolar dead space fraction values in the diagnosis of pulmonary embolism.
Songur Yücel Z; Metin Aksu N; Akkaş M
Pulmonology; 2020; 26(4):192-197. PubMed ID: 32067906
[TBL] [Abstract][Full Text] [Related]
2. Steady-state end-tidal alveolar dead space fraction and D-dimer: bedside tests to exclude pulmonary embolism.
Rodger MA; Jones G; Rasuli P; Raymond F; Djunaedi H; Bredeson CN; Wells PS
Chest; 2001 Jul; 120(1):115-9. PubMed ID: 11451825
[TBL] [Abstract][Full Text] [Related]
3. The diagnostic role of capnography in pulmonary embolism.
Kurt OK; Alpar S; Sipit T; Guven SF; Erturk H; Demirel MK; Korkmaz M; Hayran M; Kurt B
Am J Emerg Med; 2010 May; 28(4):460-5. PubMed ID: 20466226
[TBL] [Abstract][Full Text] [Related]
4. Monitoring Dead Space in Mechanically Ventilated Children: Volumetric Capnography Versus Time-Based Capnography.
Bhalla AK; Rubin S; Newth CJ; Ross P; Morzov R; Soto-Campos G; Khemani R
Respir Care; 2015 Nov; 60(11):1548-55. PubMed ID: 26199451
[TBL] [Abstract][Full Text] [Related]
5. Diagnostic accuracy of a bedside D-dimer assay and alveolar dead-space measurement for rapid exclusion of pulmonary embolism: a multicenter study.
Kline JA; Israel EG; Michelson EA; O'Neil BJ; Plewa MC; Portelli DC
JAMA; 2001 Feb; 285(6):761-8. PubMed ID: 11176914
[TBL] [Abstract][Full Text] [Related]
6. Pre and post-pulmonary thromboendarterectomies capnographic variables.
Moreira MM; Terzi RG; Vieira RW; Petrucci Junior O; Paschoal IA; Oliveira PP; Vilarinho KA; Braile DM
Rev Bras Cir Cardiovasc; 2007; 22(4):509-12. PubMed ID: 18488123
[TBL] [Abstract][Full Text] [Related]
7. Volumetric or time-based capnography for excluding pulmonary embolism in outpatients?
Verschuren F; Sanchez O; Righini M; Heinonen E; Le Gal G; Meyer G; Perrier A; Thys F
J Thromb Haemost; 2010 Jan; 8(1):60-7. PubMed ID: 19874457
[TBL] [Abstract][Full Text] [Related]
8. Pulmonary embolism in Bradford, UK: role of end-tidal CO2 as a screening tool.
Riaz I; Jacob B
Clin Med (Lond); 2014 Apr; 14(2):128-33. PubMed ID: 24715122
[TBL] [Abstract][Full Text] [Related]
9. Values of the Wells and revised Geneva scores combined with D-dimer in diagnosing elderly pulmonary embolism patients.
Guo DJ; Zhao C; Zou YD; Huang XH; Hu JM; Guo L
Chin Med J (Engl); 2015 Apr; 128(8):1052-7. PubMed ID: 25881599
[TBL] [Abstract][Full Text] [Related]
10. Use of the alveolar dead space fraction (Vd/Vt) and plasma D-dimers to exclude acute pulmonary embolism in ambulatory patients.
Kline JA; Meek S; Boudrow D; Warner D; Colucciello S
Acad Emerg Med; 1997 Sep; 4(9):856-63. PubMed ID: 9305426
[TBL] [Abstract][Full Text] [Related]
11. The additional use of end-tidal alveolar dead space fraction following D-dimer test to improve diagnostic accuracy for pulmonary embolism in the emergency department.
Yoon YH; Lee SW; Jung DM; Moon SW; Horn JK; Hong YS
Emerg Med J; 2010 Sep; 27(9):663-7. PubMed ID: 20798097
[TBL] [Abstract][Full Text] [Related]
12. Alveolar dead space and capnographic variables before and after thrombolysis in patients with acute pulmonary embolism.
Moreira MM; Terzi RG; Carvalho CH; de Oliveira Neto AF; Pereira MC; Paschoal IA
Vasc Health Risk Manag; 2009; 5(1):9-12. PubMed ID: 19436653
[TBL] [Abstract][Full Text] [Related]
13. Volumetric capnography as a screening test for pulmonary embolism in the emergency department.
Verschuren F; Liistro G; Coffeng R; Thys F; Roeseler J; Zech F; Reynaert M
Chest; 2004 Mar; 125(3):841-50. PubMed ID: 15006940
[TBL] [Abstract][Full Text] [Related]
14. Clinical probability and alveolar dead space measurement for suspected pulmonary embolism in patients with an abnormal D-dimer test result.
Sanchez O; Wermert D; Faisy C; Revel MP; Diehl JL; Sors H; Meyer G
J Thromb Haemost; 2006 Jul; 4(7):1517-22. PubMed ID: 16839348
[TBL] [Abstract][Full Text] [Related]
15. BET 1: Everything in graduation: arterial/end-tidal CO
O'Rourke J; MacDonald B
Emerg Med J; 2021 Jul; 38(7):361-363. PubMed ID: 34449417
[TBL] [Abstract][Full Text] [Related]
16. Excluding Pulmonary Embolism with End-tidal Carbon Dioxide: Accuracy, Cost, and Harm Avoidance.
Prentice D; Deroche CB; Wipke-Tevis DD
West J Nurs Res; 2020 Dec; 42(12):1022-1030. PubMed ID: 32406785
[TBL] [Abstract][Full Text] [Related]
17. Capnometry in suspected pulmonary embolism with positive D-dimer in the field.
Rumpf TH; Krizmaric M; Grmec S
Crit Care; 2009; 13(6):R196. PubMed ID: 19995420
[TBL] [Abstract][Full Text] [Related]
18. D-dimer and exhaled CO2/O2 to detect segmental pulmonary embolism in moderate-risk patients.
Kline JA; Hogg MM; Courtney DM; Miller CD; Jones AE; Smithline HA; Klekowski N; Lanier R
Am J Respir Crit Care Med; 2010 Sep; 182(5):669-75. PubMed ID: 20448094
[TBL] [Abstract][Full Text] [Related]
19. Preliminary study of the capnogram waveform area to screen for pulmonary embolism.
Kline JA; Arunachlam M
Ann Emerg Med; 1998 Sep; 32(3 Pt 1):289-96. PubMed ID: 9737489
[TBL] [Abstract][Full Text] [Related]
20. End Tidal Carbon Dioxide as a Screening Tool for Computed Tomography Angiogram in Postoperative Orthopaedic Patients Suspected of Pulmonary Embolism.
Ramme AJ; Iturrate E; Dweck E; Steiger DJ; Hutzler LH; Fang Y; Wang B; Bosco JA; Sigmund AE
J Arthroplasty; 2016 Oct; 31(10):2348-52. PubMed ID: 27113941
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]