BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

152 related articles for article (PubMed ID: 32072247)

  • 1. Establishing local diagnostic reference levels for pediatric percutaneous transhepatic cholangiography interventions and optimizing the routine practice.
    Farah J; Pariente D; Esaki A; Deleuze C; Adamsbaum C; Franchi-Abella S
    Pediatr Radiol; 2020 May; 50(6):827-832. PubMed ID: 32072247
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Institutional Diagnostic Reference Levels and Peak Skin Doses in selected diagnostic and therapeutic interventional radiology procedures.
    Papanastasiou E; Protopsaltis A; Finitsis S; Hatzidakis A; Prassopoulos P; Siountas A
    Phys Med; 2021 Sep; 89():63-71. PubMed ID: 34352677
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Patient radiation dose in percutaneous biliary interventions: recommendations for DRLs on the basis of a multicentre study.
    Schmitz D; Vogl T; Nour-Eldin NA; Radeleff B; Kröger JC; Mahnken AH; Ittrich H; Gehl HB; Plessow B; Böttcher J; Tacke J; Wispler M; Rosien U; Schorr W; Joerdens M; Glaser N; Fuchs ES; Tal A; Friesenhahn-Ochs B; Leimbach T; Höpner L; Weber M; Gölder S; Böhmig M; Hetjens S; Rudi J; Schegerer A
    Eur Radiol; 2019 Jul; 29(7):3390-3400. PubMed ID: 31016441
    [TBL] [Abstract][Full Text] [Related]  

  • 4. An audit of patient radiation doses in interventional radiology at a South African hospital.
    Slave O; Mahomed N
    SA J Radiol; 2023; 27(1):2559. PubMed ID: 36756356
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Local patient dose diagnostic reference levels in pediatric interventional cardiology in Chile using age bands and patient weight values.
    Ubeda C; Miranda P; Vano E
    Med Phys; 2015 Feb; 42(2):615-622. PubMed ID: 28102608
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Local diagnostic reference levels for paediatric non-cardiac interventional radiology procedures.
    Morcillo AB; Alejo L; Huerga C; Bayón J; Obesso A; Corredoira E; Novo JR; Hernández T; Ponce MD; Fernández L; Rodríguez R; Garzón G; Vañó E; Guibelalde E
    Phys Med; 2020 Apr; 72():1-6. PubMed ID: 32179406
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Diagnostic Reference Levels for Fluoroscopy-guided Gastrointestinal Procedures in Japan from the REX-GI Study: A Nationwide Multicentre Prospective Observational Study.
    Hayashi S; Takenaka M; Hosono M; Kogure H; Hasatani K; Suda T; Maruyama H; Matsunaga K; Ihara H; Yoshio T; Nagaike K; Yamada T; Yakushijin T; Takagi T; Tsumura H; Kurita A; Asai S; Ito Y; Kuwai T; Hori Y; Maetani I; Ikezawa K; Iwashita T; Matsumoto K; Fujisawa T; Nishida T
    Lancet Reg Health West Pac; 2022 Mar; 20():100376. PubMed ID: 35036979
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Biliary sludge after liver transplantation: 1. Imaging findings and efficacy of various imaging procedures.
    Barton P; Maier A; Steininger R; Mühlbacher F; Lechner G
    AJR Am J Roentgenol; 1995 Apr; 164(4):859-64. PubMed ID: 7726038
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Biliary complications in pediatric liver transplantation: findings of percutaneous transhepatic cholangiography in a large single-center cohort.
    Dulcetta L; Marra P; Carbone FS; Bonaffini PA; Sallemi C; Sansotta N; Colledan M; D'Antiga L; Sironi S
    Pediatr Radiol; 2022 May; 52(6):1061-1074. PubMed ID: 35107594
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Ionizing radiation exposure in complex percutaneous coronary intervention: Defining local diagnostic reference levels in the catheterization laboratory.
    Costa H; Espírito-Santo M; Bispo J; Guedes J; Paulo G; Mimoso J; Palmeiro H; Baptista Gonçalves R; Vinhas H
    Rev Port Cardiol; 2024 Feb; ():. PubMed ID: 38336222
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Nationwide Survey of Medical Radiation Exposure on Cardiovascular Examinations in Japan].
    Ishibashi T; Takei Y; Sakamoto H; Yamashita Y; Kato M; Tsukamoto A; Matsumoto K; Mizutani H; Suzuki S; Katoh Y; Chida K
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2020; 76(1):64-71. PubMed ID: 31956188
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Establishment of Diagnostic Reference Levels in Portuguese Interventional Radiology departments.
    Pimenta A; Azevedo L; Ramos I; Santos J
    Eur J Radiol; 2024 Apr; 173():111377. PubMed ID: 38382425
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Fluoroscopy-guided insertion of nasojejunal tubes in children - setting local diagnostic reference levels.
    Vitta L; Raghavan A; Morrell R; Sprigg A
    Pediatr Radiol; 2009 Nov; 39(11):1203-8. PubMed ID: 19789863
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Radiation dose and diagnostic reference levels for four interventional radiology procedures: results of the prospective European multicenter survey EUCLID.
    Schegerer AA; Frija G; Paulo G; Jaschke W; Tsapaki V; Repussard J; Damilakis J
    Eur Radiol; 2021 Dec; 31(12):9346-9360. PubMed ID: 33991223
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of technical success and complications of percutaneous transhepatic cholangiography and biliary drainage between patients with and without transplanted liver.
    Morita S; Kitanosono T; Lee D; Syed L; Butani D; Holland G; Waldman D
    AJR Am J Roentgenol; 2012 Nov; 199(5):1149-52. PubMed ID: 23096192
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Investigation of reference levels and radiation dose associated with abdominal EVAR (endovascular aneurysm repair) procedures across several European Centres.
    Tuthill E; O'Hora L; O'Donohoe M; Panci S; Gilligan P; Campion D; Trenti R; Fox E; Catania D; Rainford L
    Eur Radiol; 2017 Nov; 27(11):4846-4856. PubMed ID: 28523354
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Local Diagnostic Reference Levels in Interventional Radiology.
    Ou-Saada I; Boujemaa S; Campoleoni M; Brambilla R; Bentayeb F
    J Med Imaging Radiat Sci; 2020 Jun; 51(2):307-311. PubMed ID: 32278664
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Radiation exposure in biliary procedures performed to manage anastomotic strictures in pediatric liver transplant recipients: comparison between radiation exposure levels using an image intensifier and a flat-panel detector-based system.
    Miraglia R; Maruzzelli L; Tuzzolino F; Indovina PL; Luca A
    Cardiovasc Intervent Radiol; 2013 Dec; 36(6):1670-1676. PubMed ID: 23765127
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Multicenter Survey on Radiation Dose of Cardiac Intervention].
    Hayashi T; Watanabe Y; Imazeki M; Takeda K; Sakiyama K; Hasegawa R; Tajima O; Tsukamoto A; Sato H; Shiraki H; Abe O
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2020; 76(7):715-724. PubMed ID: 32684564
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Diagnostic Reference Levels, Deterministic and Stochastic Risks in Pediatric Interventional Cardiology Procedures.
    Rizk C; Fares G; Vanhavere F; Saliba Z; Farah J
    Health Phys; 2020 Jan; 118(1):85-95. PubMed ID: 31764423
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.