These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

273 related articles for article (PubMed ID: 32081396)

  • 1. Biomechanical analysis of the stability of anterograde reamed intramedullary nails in femoral spiral fractures.
    Herrera A; Rosell J; Ibarz E; Albareda J; Gabarre S; Mateo J; Gracia L
    Injury; 2020 Apr; 51 Suppl 1():S74-S79. PubMed ID: 32081396
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparative analysis of the biomechanical behavior of anterograde/retrograde nailing in supracondylar femoral fractures.
    Herrera A; Albareda J; Gabarre S; Ibarz E; Puértolas S; Mateo J; Gracia L
    Injury; 2020 Apr; 51 Suppl 1():S80-S88. PubMed ID: 32067772
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Influence of screw combination and nail materials in the stability of anterograde reamed intramedullary nail in distal femoral fractures.
    Gabarre S; Albareda J; Gracia L; Puértolas S; Ibarz E; Herrera A
    Injury; 2017 Nov; 48 Suppl 6():S47-S53. PubMed ID: 29162241
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Influence of gap size, screw configuration, and nail materials in the stability of anterograde reamed intramedullary nail in femoral transverse fractures.
    Gabarre S; Albareda J; Gracia L; Puértolas S; Ibarz E; Herrera A
    Injury; 2017 Nov; 48 Suppl 6():S40-S46. PubMed ID: 29162240
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Biomechanical behavior of retrograde intramedullary nails in distal femoral fractures.
    Albareda-Albareda J; Gabarre-Raso S; Rosell-Pradas J; Puértolas-Broto S; Ibarz-Montaner E; Redondo-Trasobares B; Gómez-Vallejo J; Blanco-Rubio N; Sánchez-Gimeno M; Herrera-Rodríguez A; Gracia-Villa L
    Injury; 2021 Jul; 52 Suppl 4():S76-S86. PubMed ID: 33642084
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Immediate weight-bearing after treatment of a comminuted fracture of the femoral shaft with a statically locked intramedullary nail.
    Brumback RJ; Toal TR; Murphy-Zane MS; Novak VP; Belkoff SM
    J Bone Joint Surg Am; 1999 Nov; 81(11):1538-44. PubMed ID: 10565645
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Modification of elastic stable intramedullary nailing with a 3rd nail in a femoral spiral fracture model - results of biomechanical testing and a prospective clinical study.
    Kaiser MM; Stratmann C; Zachert G; Schulze-Hessing M; Gros N; Eggert R; Rapp M
    BMC Musculoskelet Disord; 2014 Jan; 15():3. PubMed ID: 24397612
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Success of exchange reamed intramedullary nailing for femoral shaft nonunion or delayed union.
    Hak DJ; Lee SS; Goulet JA
    J Orthop Trauma; 2000; 14(3):178-82. PubMed ID: 10791668
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Prospective randomized study of reamed versus unreamed femoral intramedullary nailing: an assessment of procedures.
    Shepherd LE; Shean CJ; Gelalis ID; Lee J; Carter VS
    J Orthop Trauma; 2001 Jan; 15(1):28-32; discussion 32-3. PubMed ID: 11147684
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Biomechanical comparison of locked plate osteosynthesis, reamed and unreamed nailing in conventional interlocking technique, and unreamed angle stable nailing in distal tibia fractures.
    Hoegel FW; Hoffmann S; Weninger P; Bühren V; Augat P
    J Trauma Acute Care Surg; 2012 Oct; 73(4):933-8. PubMed ID: 22710777
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Biomechanical assessment of composite versus metallic intramedullary nailing system in femoral shaft fractures: A finite element study.
    Samiezadeh S; Tavakkoli Avval P; Fawaz Z; Bougherara H
    Clin Biomech (Bristol, Avon); 2014 Aug; 29(7):803-10. PubMed ID: 24951320
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Increasing nail-cortical contact to increase fixation stability and decrease implant strain in antegrade locked nailing of distal femoral fractures: a biomechanical study.
    Huang SC; Lin CC; Lin J
    J Trauma; 2009 Feb; 66(2):436-42. PubMed ID: 19065112
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Biomechanical analysis of a synthetic femoral spiral fracture model: Do end caps improve retrograde flexible intramedullary nail fixation?
    Kaiser MM; Zachert G; Wendlandt R; Rapp M; Eggert R; Stratmann C; Wessel LM; Schulz AP; Kienast BJ
    J Orthop Surg Res; 2011 Sep; 6():46. PubMed ID: 21923948
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Improve biomechanical stability using intramedullary nails with femoral neck protection in femoral shaft fractures.
    Yuan D; Wu Z; Luo S; Zhou Y; Teng J; Ye C
    Comput Methods Programs Biomed; 2022 Oct; 225():107078. PubMed ID: 36037604
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Are the unreamed nails indicated in diaphyseal fractures of the lower extremity? A biomechanical study.
    Albareda J; Ibarz E; Mateo J; Suñer S; Lozano C; Gómez J; Redondo B; Torres A; Herrera A; Gracia L
    Injury; 2021 Jul; 52 Suppl 4():S61-S70. PubMed ID: 33707035
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A biomechanical investigation of the effects of static fixation and dynamization after interlocking femoral nailing: a finite element study.
    Shih KS; Hsu CC; Hsu TP
    J Trauma Acute Care Surg; 2012 Feb; 72(2):E46-53. PubMed ID: 22327998
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Anterograde femoral nailing with a reamed interlocking titanium alloy nail.
    Debrauwer S; Hendrix K; Verdonk R
    Acta Orthop Belg; 2000 Dec; 66(5):484-9. PubMed ID: 11196373
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Fresh femoral shaft fractures treated with un-reamed intramedullary nail: 203 cases].
    Wu Y; Wang M; Sun L; An G; Rong G
    Zhonghua Wai Ke Za Zhi; 2000 Jun; 38(6):418-21, 27. PubMed ID: 11832072
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Biomechanical factors affecting fracture stability and femoral bursting in closed intramedullary nailing of femoral shaft fractures, with illustrative case presentations.
    Johnson KD; Tencer AF; Sherman MC
    J Orthop Trauma; 1987; 1(1):1-11. PubMed ID: 3506582
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The outcome of closed, intramedullary exchange nailing with reamed insertion in the treatment of femoral shaft nonunions.
    Shroeder JE; Mosheiff R; Khoury A; Liebergall M; Weil YA
    J Orthop Trauma; 2009 Oct; 23(9):653-7. PubMed ID: 19897987
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 14.