These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

400 related articles for article (PubMed ID: 32084219)

  • 1. Biomechanical comparison of pedicle screw fixation strength in synthetic bones: Effects of screw shape, core/thread profile and cement augmentation.
    Liu MY; Tsai TT; Lai PL; Hsieh MK; Chen LH; Tai CL
    PLoS One; 2020; 15(2):e0229328. PubMed ID: 32084219
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Pullout strength of pedicle screws with cement augmentation in severe osteoporosis: a comparative study between cannulated screws with cement injection and solid screws with cement pre-filling.
    Chen LH; Tai CL; Lee DM; Lai PL; Lee YC; Niu CC; Chen WJ
    BMC Musculoskelet Disord; 2011 Feb; 12():33. PubMed ID: 21284883
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Primary pedicle screw augmentation in osteoporotic lumbar vertebrae: biomechanical analysis of pedicle fixation strength.
    Burval DJ; McLain RF; Milks R; Inceoglu S
    Spine (Phila Pa 1976); 2007 May; 32(10):1077-83. PubMed ID: 17471088
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Characteristics of pullout failure in conical and cylindrical pedicle screws after full insertion and back-out.
    Abshire BB; McLain RF; Valdevit A; Kambic HE
    Spine J; 2001; 1(6):408-14. PubMed ID: 14588297
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A Biomechanical Comparison of Expansive Pedicle Screws for Severe Osteoporosis: The Effects of Screw Design and Cement Augmentation.
    Tai CL; Tsai TT; Lai PL; Chen YL; Liu MY; Chen LH
    PLoS One; 2015; 10(12):e0146294. PubMed ID: 26720724
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Influence of the screw augmentation technique and a diameter increase on pedicle screw fixation in the osteoporotic spine: pullout versus fatigue testing.
    Kueny RA; Kolb JP; Lehmann W; Püschel K; Morlock MM; Huber G
    Eur Spine J; 2014 Oct; 23(10):2196-202. PubMed ID: 25082759
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Pedicle screw design and cement augmentation in osteoporotic vertebrae: effects of fenestrations and cement viscosity on fixation and extraction.
    Choma TJ; Pfeiffer FM; Swope RW; Hirner JP
    Spine (Phila Pa 1976); 2012 Dec; 37(26):E1628-32. PubMed ID: 22996264
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Pedicle screw fixation strength: pullout versus insertional torque.
    Inceoglu S; Ferrara L; McLain RF
    Spine J; 2004; 4(5):513-8. PubMed ID: 15363421
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Pullout evaluation of sawbone experiment in different types of pedicle screws combined with bone cement augmentation for severe osteoporotic spine.
    Yang SC; Liu PH; Tu YK
    Acta Bioeng Biomech; 2018; 20(2):55-64. PubMed ID: 30220723
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Polymethylmethacrylate augmentation of cannulated pedicle screws for fixation in osteoporotic spines and comparison of its clinical results and biomechanical characteristics with the needle injection method.
    Chang MC; Kao HC; Ying SH; Liu CL
    J Spinal Disord Tech; 2013 Aug; 26(6):305-15. PubMed ID: 23887077
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Biomechanical properties of pedicle screw fixation augmented with allograft bone particles in osteoporotic vertebrae: different sizes and amounts.
    Jia C; Zhang R; Xing T; Gao H; Li H; Dong F; Zhang J; Ge P; Song P; Xu P; Zhang H; Shen C
    Spine J; 2019 Aug; 19(8):1443-1452. PubMed ID: 31009768
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Pullout strength for cannulated pedicle screws with bone cement augmentation in severely osteoporotic bone: influences of radial hole and pilot hole tapping.
    Chen LH; Tai CL; Lai PL; Lee DM; Tsai TT; Fu TS; Niu CC; Chen WJ
    Clin Biomech (Bristol); 2009 Oct; 24(8):613-8. PubMed ID: 19481845
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Pullout performance comparison of pedicle screws based on cement application and design parameters.
    Tolunay T; Başgül C; Demir T; Yaman ME; Arslan AK
    Proc Inst Mech Eng H; 2015 Nov; 229(11):786-93. PubMed ID: 26503840
    [TBL] [Abstract][Full Text] [Related]  

  • 14. PMMA-augmentation of incompletely cannulated pedicle screws: a cadaver study to determine the benefits in the osteoporotic spine.
    Goost H; Deborre C; Wirtz DC; Burger C; Prescher A; Fölsch C; Pflugmacher R; Kabir K
    Technol Health Care; 2014; 22(4):607-15. PubMed ID: 24837053
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Assessment of pedicle screw pullout strength based on various screw designs and bone densities-an ex vivo biomechanical study.
    Kim YY; Choi WS; Rhyu KW
    Spine J; 2012 Feb; 12(2):164-8. PubMed ID: 22336467
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Biomechanical analysis of pedicle screw thread differential design in an osteoporotic cadaver model.
    Mehta H; Santos E; Ledonio C; Sembrano J; Ellingson A; Pare P; Murrell B; Nuckley DJ
    Clin Biomech (Bristol); 2012 Mar; 27(3):234-40. PubMed ID: 22071427
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Biomechanical study of pedicle screw fixation in severely osteoporotic bone.
    Cook SD; Salkeld SL; Stanley T; Faciane A; Miller SD
    Spine J; 2004; 4(4):402-8. PubMed ID: 15246300
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A new technique of bone cement augmentation via the disc space for percutaneous pedicle screw fixation.
    Park CK; Park CK; Lee DC; Lee DG
    J Neurosurg Spine; 2016 Jan; 24(1):16-9. PubMed ID: 26360145
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Biomechanical comparative study of the stability of injectable pedicle screws with different lateral holes augmented with different volumes of polymethylmethacrylate in osteoporotic lumbar vertebrae.
    Liu D; Sheng J; Luo Y; Huang C; Wu HH; Zhou JJ; Zhang XJ; Zheng W
    Spine J; 2018 Sep; 18(9):1637-1644. PubMed ID: 29567517
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Revision of cannulated and perforated cement-augmented pedicle screws: a biomechanical study in human cadavers.
    Bullmann V; Schmoelz W; Richter M; Grathwohl C; Schulte TL
    Spine (Phila Pa 1976); 2010 Sep; 35(19):E932-9. PubMed ID: 20508553
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 20.