These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
105 related articles for article (PubMed ID: 3208867)
1. Experimental basis of standardized specimen collection: the effect of the site of venipuncture on the blood picture, the white blood cell differential count, and the serum albumin concentration. Leppänen EA Eur J Haematol; 1988 Nov; 41(5):445-8. PubMed ID: 3208867 [TBL] [Abstract][Full Text] [Related]
2. Unacceptable variability of hemoglobin estimation on samples obtained from ear punctures. Coburn TJ; Miller WV; Parrill WD Transfusion; 1977; 17(3):265-8. PubMed ID: 867469 [TBL] [Abstract][Full Text] [Related]
3. Variations in pleural fluid WBC count and differential counts with different sample containers and different methods. Conner BD; Lee YC; Branca P; Rogers JT; Rodriguez RM; Light RW Chest; 2003 Apr; 123(4):1181-7. PubMed ID: 12684309 [TBL] [Abstract][Full Text] [Related]
4. [Clinical reference values for laboratory hematology tests calculated using the iterative truncation method with correction: Part 2, Reference values for white blood cell (WBC) count, WBC differential including segmented neutrophil, band neutrophil, lymphocyte, monocyte, eosinophil, basophil, platelet count and mean platelet volume]. Shiga S; Koyanagi I; Ohsaga J; Ichiyama S; Kannagi R Rinsho Byori; 1999 Mar; 47(3):281-8. PubMed ID: 10228396 [TBL] [Abstract][Full Text] [Related]
5. Experimental basis of standardized specimen collection: effect of posture on blood picture. Leppänen EA; Gräsbeck R Eur J Haematol; 1988 Mar; 40(3):222-6. PubMed ID: 3356238 [TBL] [Abstract][Full Text] [Related]
6. Changes in blood counts after the administration of granulocyte-colony-stimulating factor and the collection of peripheral blood stem cells from healthy donors. Stroncek DF; Clay ME; Smith J; Ilstrup S; Oldham F; McCullough J Transfusion; 1996 Jul; 36(7):596-600. PubMed ID: 8701454 [TBL] [Abstract][Full Text] [Related]
7. Comparison of PT, aPTT, and factor VII values obtained by concurrent sample collection by direct venipuncture and peripheral venous catheters. Lindley C; Sawyer W; Haddon T; Meade J; Nolen J; Johansen L; Roberts H Pharmacotherapy; 1994; 14(2):224-8. PubMed ID: 8197044 [TBL] [Abstract][Full Text] [Related]
8. Use of capillary blood count parameters in adults. Schalk E; Heim MU; Koenigsmann M; Jentsch-Ullrich K Vox Sang; 2007 Nov; 93(4):348-53. PubMed ID: 18070280 [TBL] [Abstract][Full Text] [Related]
9. Very large amounts of peripheral blood progenitor cells eliminate severe thrombocytopenia after high-dose melphalan in advanced breast cancer patients. Benedetti G; Patoia L; Giglietti A; Alessio M; Pelicci P; Grignani F Bone Marrow Transplant; 1999 Nov; 24(9):971-9. PubMed ID: 10556956 [TBL] [Abstract][Full Text] [Related]
10. Longitudinal changes in iron and protein status of elderly Europeans. SENECA Investigators. Lesourd B; Decarli B; Dirren H Eur J Clin Nutr; 1996 Jul; 50 Suppl 2():S16-24. PubMed ID: 8841781 [TBL] [Abstract][Full Text] [Related]
11. Hemoglobin screening in prospective blood donors: a comparison of methods. Avoy DR; Canuel ML; Otton BM; Mileski EB Transfusion; 1977; 17(3):261-4. PubMed ID: 867468 [TBL] [Abstract][Full Text] [Related]
12. The predictive value of white cell or CD34+ cell count in the peripheral blood for timing apheresis and maximizing yield. Yu J; Leisenring W; Bensinger WI; Holmberg LA; Rowley SD Transfusion; 1999 May; 39(5):442-50. PubMed ID: 10335991 [TBL] [Abstract][Full Text] [Related]
13. Comparison of Hematologic and Biochemical Test Results in Blood Samples Obtained by Jugular Venipuncture Versus Nail Clip in Moluccan Cockatoos (Cacatua moluccensis). Bennett TD; Lejnieks DV; Koepke H; Grimson F; Szucs J; Omaits K; Lane R J Avian Med Surg; 2015 Dec; 29(4):303-12. PubMed ID: 26771320 [TBL] [Abstract][Full Text] [Related]
14. [The diagnostic value of high-sensitivity C-reactive protein/albumin ratio in evaluating early-onset infection in premature]. Yang C; Yang Y; Li B; Xu P; Shen Q; Yang Q Zhonghua Wei Zhong Bing Ji Jiu Yi Xue; 2016 Feb; 28(2):173-7. PubMed ID: 26911952 [TBL] [Abstract][Full Text] [Related]
15. [Safety comparison of mobilization and collection of hematopoietic stem cells between related and unrelated donors]. Zhang S; Jin H; Xu LP; Liu DH; Chen H; Liang YQ; Li T; Li FX; Wang R; Kang Q; Chen YH; Zhang XH; Han W; Huang XJ; Liu KY Zhongguo Shi Yan Xue Ye Xue Za Zhi; 2010 Aug; 18(4):1017-22. PubMed ID: 20723320 [TBL] [Abstract][Full Text] [Related]
16. Comparison of haematological analyses of blood taken from the cephalic and marginal ear veins in cats. Jacobsen JO; Jensen AL J Small Anim Pract; 1998 Feb; 39(2):94-5. PubMed ID: 9513892 [TBL] [Abstract][Full Text] [Related]
17. A new device to relieve venipuncture pain can affect haematology test results. Lima-Oliveira G; Lippi G; Salvagno GL; Campelo MD; Tajra KS; dos Santos Gomes F; Valentim CD; Romano SJ; Picheth G; Guidi GC Blood Transfus; 2014 Jan; 12 Suppl 1(Suppl 1):s6-10. PubMed ID: 24120583 [TBL] [Abstract][Full Text] [Related]
18. The relationship between hematological parameters and prognosis of children with acute ischemic stroke. Yilmaz E; Bayram Kacar A; Bozpolat A; Zararsiz G; Gorkem BS; Karakukcu M; Patiroglu T; Gumus H; Ozdemir MA; Ozcan A; Per H; Unal E Childs Nerv Syst; 2018 Apr; 34(4):655-661. PubMed ID: 29209887 [TBL] [Abstract][Full Text] [Related]
19. White blood cell counts by automated and manual methods with backlighting. Trinh M Clin Lab Sci; 1991; 4(1):45-7. PubMed ID: 10149412 [TBL] [Abstract][Full Text] [Related]
20. Concomitant spuriously elevated white blood cell count, a previously underestimated phenomenon in EDTA-dependent pseudothrombocytopenia. Xiao Y; Xu Y Platelets; 2015; 26(7):627-31. PubMed ID: 25275874 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]