These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

84 related articles for article (PubMed ID: 3209150)

  • 1. [Sequelae of experimental Nd:YAG laser iridotomies on the human corneal endothelium].
    Daus W
    Fortschr Ophthalmol; 1988; 85(3):239-42. PubMed ID: 3209150
    [No Abstract]   [Full Text] [Related]  

  • 2. [Effect of neodymium YAG laser treatment of glaucoma on endothelial cell density of the cornea].
    Schrems W; Zeuss R; Leydhecker W
    Klin Monbl Augenheilkd; 1986 Apr; 188(4):272-7. PubMed ID: 3723967
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Electron microscopic appearances of human corneal endothelium following Nd:YAG laser iridotomy.
    Power WJ; Collum LM
    Ophthalmic Surg; 1992 May; 23(5):347-50. PubMed ID: 1603537
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Endothelial corneal damage after neodymium:YAG laser treatment: pupillary membranectomies, iridotomies, capsulotomies.
    Kozobolis VP; Detorakis ET; Vlachonikolis IG; Pallikaris IG
    Ophthalmic Surg Lasers; 1998 Oct; 29(10):793-802. PubMed ID: 9793943
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Corneal endothelial changes following short pulsed laser iridotomy and surgical iridectomy.
    Wishart PK; Sherrard ES; Nagasubramanian S; Kerr Muir MG; Hitchings RA
    Trans Ophthalmol Soc U K (1962); 1986; 105 ( Pt 5)():541-8. PubMed ID: 3467505
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Peripheral iridotomy using Nd:YLF laser.
    Frangie JP; Park SB; Aquavella JV
    Ophthalmic Surg; 1992 Mar; 23(3):220-1. PubMed ID: 1574296
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Corneal endothelial damage after neodymium:YAG laser iridotomy.
    Wu SC; Jeng S; Huang SC; Lin SM
    Ophthalmic Surg Lasers; 2000; 31(5):411-6. PubMed ID: 11011710
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Neodymium YAG and dye laser iridotomy--a comparative study.
    Wishart PK; Hitchings RA
    Trans Ophthalmol Soc U K (1962); 1986; 105 ( Pt 5)():521-40. PubMed ID: 3467504
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparison of argon laser iridotomy and sequential argon laser and Nd:YAG laser iridotomy in dark irides.
    Lim L; Seah SK; Lim AS
    Ophthalmic Surg Lasers; 1996 Apr; 27(4):285-8. PubMed ID: 8705743
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Laser peripheral iridectomy comparing Q-switched neodymium YAG with argon.
    McAllister JA; Schwartz LW; Moster M; Spaeth GL
    Trans Ophthalmol Soc U K (1962); 1985; 104 ( Pt 1)():67-9. PubMed ID: 3855339
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Recurrent closure of neodymium: YAG laser iridotomies requiring multiple treatments in pseudophakic pupillary block.
    Melamed S; Wagoner MD
    Ann Ophthalmol; 1988 Mar; 20(3):105-8. PubMed ID: 3400953
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Outpatient ND-YAG laser iridectomy for angle-closure glaucoma.
    Cambie E; De Bleecker C
    Bull Soc Belge Ophtalmol; 1984; 210():31-4. PubMed ID: 6549585
    [No Abstract]   [Full Text] [Related]  

  • 13. The effects of Nd:YAG laser iridotomy on the corneal endothelium.
    Panek WC; Lee DA; Christensen RE
    Am J Ophthalmol; 1991 Apr; 111(4):505-7. PubMed ID: 2012154
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Short exposure times in argon laser iridotomy.
    Mandelkorn RM; Mendelsohn AD; Olander KW; Zimmerman TJ
    Ophthalmic Surg; 1981 Nov; 12(11):805-9. PubMed ID: 7322456
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Stripping of Descemet's membrane after glaucoma surgery.
    Kozart DM; Eagle RC
    Ophthalmic Surg; 1981 Jun; 12(6):420-3. PubMed ID: 7266985
    [No Abstract]   [Full Text] [Related]  

  • 16. [Experimental study of corneal endothelial damage by Nd:YAG laser].
    Li XL
    Zhonghua Yan Ke Za Zhi; 1993 May; 29(3):180-2. PubMed ID: 8223050
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Prophylactic Nd:YAG-laser iridotomy versus surgical iridectomy: a randomized, prospective study.
    Schwenn O; Sell F; Pfeiffer N; Grehn F
    Ger J Ophthalmol; 1995 Nov; 4(6):374-9. PubMed ID: 8751104
    [TBL] [Abstract][Full Text] [Related]  

  • 18. In ophthalmology new possibilities for the use Nd:YAG laser.
    Sohajda Z; Békési L; Berta A
    Acta Chir Hung; 1997; 36(1-4):331-3. PubMed ID: 9408392
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Diode laser-pumped, frequency-doubled neodymium: YAG laser peripheral iridotomy.
    Abreu MM; Sierra RA; Netland PA
    Ophthalmic Surg Lasers; 1997 Apr; 28(4):305-10. PubMed ID: 9101569
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Efficacy of Nd-YAG laser iridotomies in acute angle closure glaucoma.
    Gray RH; Nairne JH; Ayliffe WH
    Br J Ophthalmol; 1989 Mar; 73(3):182-5. PubMed ID: 2706208
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.