BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

253 related articles for article (PubMed ID: 32096141)

  • 1. Decreased radiation exposure using pulsed fluoroscopy and a detachable pedicle marker and probe to place pedicle screws: a comparison to current fluoroscopy techniques and CT navigation.
    Marco RAW; Curry MC; Mujezinovic F; Linton J
    Spine Deform; 2020 Jun; 8(3):405-411. PubMed ID: 32096141
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of Effective Dose of Radiation During Pedicle Screw Placement Using Intraoperative Computed Tomography Navigation Versus Fluoroscopy in Children With Spinal Deformities.
    Dabaghi Richerand A; Christodoulou E; Li Y; Caird MS; Jong N; Farley FA
    J Pediatr Orthop; 2016; 36(5):530-3. PubMed ID: 25887838
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Intraoperative Computed Tomography-Guided Navigation for Pediatric Spine Patients Reduced Return to Operating Room for Screw Malposition Compared With Freehand/Fluoroscopic Techniques.
    Baky FJ; Milbrandt T; Echternacht S; Stans AA; Shaughnessy WJ; Larson AN
    Spine Deform; 2019 Jul; 7(4):577-581. PubMed ID: 31202374
    [TBL] [Abstract][Full Text] [Related]  

  • 4. How Does Patient Radiation Exposure Compare With Low-dose O-arm Versus Fluoroscopy for Pedicle Screw Placement in Idiopathic Scoliosis?
    Su AW; McIntosh AL; Schueler BA; Milbrandt TA; Winkler JA; Stans AA; Larson AN
    J Pediatr Orthop; 2017; 37(3):171-177. PubMed ID: 27453221
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Increased Radiation but No Benefits in Pedicle Screw Accuracy With Navigation versus a Freehand Technique in Scoliosis Surgery.
    Urbanski W; Jurasz W; Wolanczyk M; Kulej M; Morasiewicz P; Dragan SL; Zaluski R; Miekisiak G; Dragan SF
    Clin Orthop Relat Res; 2018 May; 476(5):1020-1027. PubMed ID: 29432262
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Spinal navigation for minimally invasive thoracic and lumbosacral spine fixation: implications for radiation exposure, operative time, and accuracy of pedicle screw placement.
    Tajsic T; Patel K; Farmer R; Mannion RJ; Trivedi RA
    Eur Spine J; 2018 Aug; 27(8):1918-1924. PubMed ID: 29667139
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of novel machine vision spinal image guidance system with existing 3D fluoroscopy-based navigation system: a randomized prospective study.
    Malham GM; Munday NR
    Spine J; 2022 Apr; 22(4):561-569. PubMed ID: 34666179
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Patient and surgeon radiation exposure during spinal instrumentation using intraoperative computed tomography-based navigation.
    Mendelsohn D; Strelzow J; Dea N; Ford NL; Batke J; Pennington A; Yang K; Ailon T; Boyd M; Dvorak M; Kwon B; Paquette S; Fisher C; Street J
    Spine J; 2016 Mar; 16(3):343-54. PubMed ID: 26686604
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Intraoperative Radiation Exposure for Patients with Double-Curve Idiopathic Scoliosis in Freehand-Technique in Comparison to Fluoroscopic- and CT-Based Navigation.
    Berlin C; Quante M; Thomsen B; Köszegvary M; Platz U; Halm H
    Z Orthop Unfall; 2021 Aug; 159(4):412-420. PubMed ID: 32365396
    [TBL] [Abstract][Full Text] [Related]  

  • 10. O-Arm Accuracy and Radiation Exposure in Adult Deformity Surgery.
    Croci DM; Nguyen S; Streitmatter SW; Sherrod BA; Hardy J; Cole KL; Gamblin AS; Bisson EF; Mazur MD; Dailey AT
    World Neurosurg; 2023 Mar; 171():e440-e446. PubMed ID: 36528322
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Percutaneous pedicle screw placement under single dimensional fluoroscopy with a designed pedicle finder-a technical note and case series.
    Tsuang FY; Chen CH; Kuo YJ; Tseng WL; Chen YS; Lin CJ; Liao CJ; Lin FH; Chiang CJ
    Spine J; 2017 Sep; 17(9):1373-1380. PubMed ID: 28645672
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Robotic versus fluoroscopy-guided pedicle screw insertion for metastatic spinal disease: a matched-cohort comparison.
    Solomiichuk V; Fleischhammer J; Molliqaj G; Warda J; Alaid A; von Eckardstein K; Schaller K; Tessitore E; Rohde V; Schatlo B
    Neurosurg Focus; 2017 May; 42(5):E13. PubMed ID: 28463620
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Intraoperative computed tomography image-guided navigation for posterior thoracolumbar spinal instrumentation in spinal deformity surgery.
    Tormenti MJ; Kostov DB; Gardner PA; Kanter AS; Spiro RM; Okonkwo DO
    Neurosurg Focus; 2010 Mar; 28(3):E11. PubMed ID: 20192656
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparative radiation exposure using standard fluoroscopy versus cone-beam computed tomography for posterior instrumented fusion in adolescent idiopathic scoliosis.
    OʼDonnell C; Maertens A; Bompadre V; Wagner TA; Krengel W
    Spine (Phila Pa 1976); 2014 Jun; 39(14):E850-5. PubMed ID: 24732839
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Pedicle screw placement accuracy using ultra-low radiation imaging with image enhancement versus conventional fluoroscopy in minimally invasive transforaminal lumbar interbody fusion: an internally randomized controlled trial.
    Nayar G; Blizzard DJ; Wang TY; Cook S; Back AG; Vincent D; Karikari IO
    J Neurosurg Spine; 2018 Feb; 28(2):186-193. PubMed ID: 29192879
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Intraoperative CT-guided navigation versus fluoroscopy for percutaneous pedicle screw placement in 192 patients: a comparative analysis.
    La Rocca G; Mazzucchi E; Pignotti F; Nasto LA; Galieri G; Olivi A; De Santis V; Rinaldi P; Pola E; Sabatino G
    J Orthop Traumatol; 2022 Sep; 23(1):44. PubMed ID: 36048284
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Novel Machine Vision Image Guidance System Significantly Reduces Procedural Time and Radiation Exposure Compared With 2-dimensional Fluoroscopy-based Guidance in Pediatric Deformity Surgery.
    Comstock CP; Wait E
    J Pediatr Orthop; 2023 May-Jun 01; 43(5):e331-e336. PubMed ID: 36882892
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of Radiation Exposure Between O-Arm Navigated and C-Arm Guided Screw Placement in Minimally Invasive Transforaminal Lumbar Interbody Fusion.
    Chang CC; Chang HK; Wu JC; Tu TH; Cheng H; Huang WC
    World Neurosurg; 2020 Jul; 139():e489-e495. PubMed ID: 32311567
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Risk-benefit analysis of navigation techniques for vertebral transpedicular instrumentation: a prospective study.
    Noriega DC; Hernández-Ramajo R; Rodríguez-Monsalve Milano F; Sanchez-Lite I; Toribio B; Ardura F; Torres R; Corredera R; Kruger A
    Spine J; 2017 Jan; 17(1):70-75. PubMed ID: 27503262
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Learning curve analysis of 3D-fluoroscopy image-guided pedicle screw insertions in lumbar single-level fusion procedures.
    Balling H
    Arch Orthop Trauma Surg; 2018 Nov; 138(11):1501-1509. PubMed ID: 29982886
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.