These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
144 related articles for article (PubMed ID: 32097361)
41. Assessment of Cochlear Trauma During Cochlear Implantation Using Electrocochleography and Cone Beam Computed Tomography. Dalbert A; Huber A; Veraguth D; Roosli C; Pfiffner F Otol Neurotol; 2016 Jun; 37(5):446-53. PubMed ID: 26945317 [TBL] [Abstract][Full Text] [Related]
42. [Use of intraoperative round window electrocochleography for assessment of cochlear implantation safety]. Wang L; Cao K; Wang Z Lin Chuang Er Bi Yan Hou Ke Za Zhi; 2006 Sep; 20(18):822-4. PubMed ID: 17144488 [TBL] [Abstract][Full Text] [Related]
43. Cochlear implantation requiring a retrofacial approach to the round window. Allen KP; Bartels LJ; Isaacson B Otol Neurotol; 2015 Mar; 36(3):e84-6. PubMed ID: 25502454 [TBL] [Abstract][Full Text] [Related]
44. Comparison of round window and cochleostomy approaches with a prototype hearing preservation electrode. Briggs RJ; Tykocinski M; Xu J; Risi F; Svehla M; Cowan R; Stover T; Erfurt P; Lenarz T Audiol Neurootol; 2006; 11 Suppl 1():42-8. PubMed ID: 17063010 [TBL] [Abstract][Full Text] [Related]
45. Correlation of Electrophysiological Properties and Hearing Preservation in Cochlear Implant Patients. Dalbert A; Sim JH; Gerig R; Pfiffner F; Roosli C; Huber A Otol Neurotol; 2015 Aug; 36(7):1172-80. PubMed ID: 25839980 [TBL] [Abstract][Full Text] [Related]
46. Benefit of Preoperative Temporal Bone CT for Atraumatic Cochlear Implantation. Karkas A; Champfleur NM; Uziel A; Mondain M; Puel JL; Venail F Otol Neurotol; 2018 Mar; 39(3):e186-e194. PubMed ID: 29342055 [TBL] [Abstract][Full Text] [Related]
47. Cochlear Microphonics in Hearing Preservation Cochlear Implantees. Lorens A; Walkowiak A; Polak M; Kowalczuk A; Furmanek M; Skarzynski H; Obrycka A J Int Adv Otol; 2019 Dec; 15(3):345-351. PubMed ID: 31846910 [TBL] [Abstract][Full Text] [Related]
48. Simultaneous Intra- and Extracochlear Electrocochleography During Cochlear Implantation to Enhance Response Interpretation. Sijgers L; Pfiffner F; Grosse J; Dillier N; Koka K; Röösli C; Huber A; Dalbert A Trends Hear; 2021; 25():2331216521990594. PubMed ID: 33710919 [TBL] [Abstract][Full Text] [Related]
49. Hydraulic insertions of cochlear implant electrode arrays into the human cadaver cochlea: preliminary findings. Geraldine Zuniga M; Lenarz T; Rau TS Eur Arch Otorhinolaryngol; 2022 Jun; 279(6):2827-2835. PubMed ID: 34390390 [TBL] [Abstract][Full Text] [Related]
50. Preservation of cochlear structures and hearing when using the Nucleus Slim Straight (CI422) electrode in children. Skarzynski H; Matusiak M; Lorens A; Furmanek M; Pilka A; Skarzynski PH J Laryngol Otol; 2016 Apr; 130(4):332-9. PubMed ID: 26763105 [TBL] [Abstract][Full Text] [Related]
51. Chronic cochlear implantation with and without electric stimulation in a mouse model induces robust cochlear influx of CX3CR1 Claussen AD; Quevedo RV; Kirk JR; Higgins T; Mostaert B; Rahman MT; Oleson J; Hernandez R; Hirose K; Hansen MR Hear Res; 2022 Dec; 426():108510. PubMed ID: 35527124 [TBL] [Abstract][Full Text] [Related]
52. Deep insertion - round window approach by using SRA electrode. Skarżyński H; Matusiak M; Furmanek M; Skarzyński PH Cochlear Implants Int; 2014 May; 15 Suppl 1():S4-7. PubMed ID: 24869441 [TBL] [Abstract][Full Text] [Related]
53. Cochleostomy versus round window insertions: influence on functional outcomes in electric-acoustic stimulation of the auditory system. Adunka OF; Dillon MT; Adunka MC; King ER; Pillsbury HC; Buchman CA Otol Neurotol; 2014 Apr; 35(4):613-8. PubMed ID: 24557034 [TBL] [Abstract][Full Text] [Related]
54. An animal model of cochlear implantation with an intracochlear fluid delivery system. Nguyen Y; Couloigner V; Rudic M; Nguyen Y; Couloigner V; Rudic M; Grayeli AB; Ferrary E; Sterkers O Acta Otolaryngol; 2009 Nov; 129(11):1153-9. PubMed ID: 19863303 [TBL] [Abstract][Full Text] [Related]
55. The Role of Preoperative Steroids in Atraumatic Cochlear Implantation Surgery. Lo J; Campbell L; Sale P; Chambers S; Hampson A; Eastwood H; O'Leary S Otol Neurotol; 2017 Sep; 38(8):1118-1124. PubMed ID: 28700398 [TBL] [Abstract][Full Text] [Related]
56. Endolymphatic hydrops is prevalent in the first weeks following cochlear implantation. Smeds H; Eastwood HT; Hampson AJ; Sale P; Campbell LJ; Arhatari BD; Mansour S; O'Leary SJ Hear Res; 2015 Sep; 327():48-57. PubMed ID: 25987505 [TBL] [Abstract][Full Text] [Related]
57. Cochlear implantation via the round window membrane minimizes trauma to cochlear structures: a histologically controlled insertion study. Adunka O; Unkelbach MH; Mack M; Hambek M; Gstoettner W; Kiefer J Acta Otolaryngol; 2004 Sep; 124(7):807-12. PubMed ID: 15370564 [TBL] [Abstract][Full Text] [Related]
58. Round window membrane insertion with perimodiolar cochlear implant electrodes. Coordes A; Ernst A; Brademann G; Todt I Otol Neurotol; 2013 Aug; 34(6):1027-32. PubMed ID: 23507991 [TBL] [Abstract][Full Text] [Related]
59. Hearing preservation surgery: cochleostomy or round window approach? A systematic review. Havenith S; Lammers MJ; Tange RA; Trabalzini F; della Volpe A; van der Heijden GJ; Grolman W Otol Neurotol; 2013 Jun; 34(4):667-74. PubMed ID: 23640087 [TBL] [Abstract][Full Text] [Related]
60. Electrocochleography in Cochlear Implant Users with Residual Acoustic Hearing: A Systematic Review. Kim JS Int J Environ Res Public Health; 2020 Sep; 17(19):. PubMed ID: 32993065 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]