BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

316 related articles for article (PubMed ID: 3210070)

  • 1. Forehead pulse oximetry compared with finger pulse oximetry and arterial blood gas measurement.
    Cheng EY; Hopwood MB; Kay J
    J Clin Monit; 1988 Jul; 4(3):223-6. PubMed ID: 3210070
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Forehead SpO2 monitoring compared to finger SpO2 recording in emergency transport.
    Nuhr M; Hoerauf K; Joldzo A; Frickey N; Barker R; Gorove L; Puskas T; Kober A
    Anaesthesia; 2004 Apr; 59(4):390-3. PubMed ID: 15023111
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Accuracy of pulse oximetry in the intensive care unit.
    Van de Louw A; Cracco C; Cerf C; Harf A; Duvaldestin P; Lemaire F; Brochard L
    Intensive Care Med; 2001 Oct; 27(10):1606-13. PubMed ID: 11685301
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Buccal pulse oximeter is more accurate than finger pulse oximeter in measuring oxygen saturation.
    O'Leary RJ; Landon M; Benumof JL
    Anesth Analg; 1992 Oct; 75(4):495-8. PubMed ID: 1530160
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Design and evaluation of a new reflectance pulse oximeter sensor.
    Mendelson Y; Kent JC; Yocum BL; Birle MJ
    Med Instrum; 1988 Aug; 22(4):167-73. PubMed ID: 3173170
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Skin reflectance pulse oximetry: in vivo measurements from the forearm and calf.
    Mendelson Y; McGinn MJ
    J Clin Monit; 1991 Jan; 7(1):7-12. PubMed ID: 1999702
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Influence of digital clubbing on oxygen saturation measurements by pulse-oximetry in cystic fibrosis patients.
    Van Ginderdeuren F; Van Cauwelaert K; Malfroot A
    J Cyst Fibros; 2006 May; 5(2):125-8. PubMed ID: 16504602
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Accuracy of the Masimo SET® LNCS neo peripheral pulse oximeter in cyanotic congenital heart disease.
    Griksaitis MJ; Scrimgeour GE; Pappachan JV; Baldock AJ
    Cardiol Young; 2016 Aug; 26(6):1183-6. PubMed ID: 26471067
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Clinical investigation of a new combined pulse oximetry and carbon dioxide tension sensor in adult anaesthesia.
    Rohling R; Biro P
    J Clin Monit Comput; 1999 Jan; 15(1):23-7. PubMed ID: 12578058
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A multicentre prospective observational study comparing arterial blood gas values to those obtained by pulse oximeters used in adult patients attending Australian and New Zealand hospitals.
    Pilcher J; Ploen L; McKinstry S; Bardsley G; Chien J; Howard L; Lee S; Beckert L; Swanney M; Weatherall M; Beasley R
    BMC Pulm Med; 2020 Jan; 20(1):7. PubMed ID: 31918697
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Forehead-mounted reflectance oximetry for in-cockpit hypoxia early detection and warning.
    Simmons RG; Chandler JF; Horning DS
    Aviat Space Environ Med; 2012 Nov; 83(11):1067-76. PubMed ID: 23156095
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Evaluation of pulse oximeter at the nasal septum during general anesthesia: comparison with finger oximeter.
    Oh Y; Kim DK; Ryu DK; Choi JW
    J Anesth; 2024 Jun; 38(3):364-370. PubMed ID: 38502324
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Technical note: Evaluation of a wireless pulse oximeter for measuring arterial oxygen saturation and pulse rate in newborn Holstein Friesian calves.
    Kanz P; Krieger S; Drillich M; Iwersen M
    J Dairy Sci; 2018 Jul; 101(7):6437-6442. PubMed ID: 29705429
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Placement of finger oximeter on the ear: comparison with oxygen saturation values taken from the finger.
    Shakespeare J; Parkes E; Gilsenan C; Ali A
    Br J Nurs; 2021 Jun; 30(11):666-670. PubMed ID: 34109812
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Accuracy of a pulse oximeter during hypoxia].
    Tachibana C; Fukada T; Hasegawa R; Satoh K; Furuya Y; Ohe Y
    Masui; 1996 Apr; 45(4):479-82. PubMed ID: 8725606
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparative Analysis of Oxygen Saturation by Pulse Oximetry and Arterial Blood Gas in Hypoxemic Patients in a Tertiary Care Hospital.
    Abraham EA; Verma G; Arafat Y; Acharya S; Kumar S; Pantbalekundri N
    Cureus; 2023 Jul; 15(7):e42447. PubMed ID: 37637606
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Study of Oxygen Saturation by Pulse Oximetry and Arterial Blood Gas in ICU Patients: A Descriptive Cross-sectional Study.
    Rauniyar N; Pujari S; Shrestha P
    JNMA J Nepal Med Assoc; 2020 Oct; 58(230):789-793. PubMed ID: 34504355
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Accuracy of methemoglobin detection by pulse CO-oximetry during hypoxia.
    Feiner JR; Bickler PE; Mannheimer PD
    Anesth Analg; 2010 Jul; 111(1):143-8. PubMed ID: 20007731
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Determination of saturation, heart rate, and respiratory rate at forearm using a Nellcor™ forehead SpO
    Harju J; Vehkaoja A; Lindroos V; Kumpulainen P; Liuhanen S; Yli-Hankala A; Oksala N
    J Clin Monit Comput; 2017 Oct; 31(5):1019-1026. PubMed ID: 27752932
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Evidence for the need of bedside accuracy of pulse oximetry in an intensive care unit.
    Seguin P; Le Rouzo A; Tanguy M; Guillou YM; Feuillu A; Mallédant Y
    Crit Care Med; 2000 Mar; 28(3):703-6. PubMed ID: 10752818
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 16.