BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

459 related articles for article (PubMed ID: 32105916)

  • 1. Correlation between optic nerve sheath diameter measured on imaging with acute pathologies found on computed tomography of trauma patients.
    Jenjitranant P; Tunlayadechanont P; Prachanukool T; Kaewlai R
    Eur J Radiol; 2020 Apr; 125():108875. PubMed ID: 32105916
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Ultrasonographic measured optic nerve sheath diameter as an accurate and quick monitor for changes in intracranial pressure.
    Maissan IM; Dirven PJ; Haitsma IK; Hoeks SE; Gommers D; Stolker RJ
    J Neurosurg; 2015 Sep; 123(3):743-7. PubMed ID: 25955869
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Optic nerve sheath diameter based on preoperative brain computed tomography and intracranial pressure are positively correlated in adults with hydrocephalus.
    Lee HC; Lee WJ; Dho YS; Cho WS; Kim YH; Park HP
    Clin Neurol Neurosurg; 2018 Apr; 167():31-35. PubMed ID: 29433056
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Optic nerve sheath diameter on computed tomography is correlated with simultaneously measured intracranial pressure in patients with severe traumatic brain injury.
    Sekhon MS; Griesdale DE; Robba C; McGlashan N; Needham E; Walland K; Shook AC; Smielewski P; Czosnyka M; Gupta AK; Menon DK
    Intensive Care Med; 2014 Sep; 40(9):1267-74. PubMed ID: 25034476
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Role of serial ultrasonic optic nerve sheath diameter monitoring in head injury.
    Thotakura AK; Marabathina NR; Danaboyina AR; Mareddy RR
    Neurochirurgie; 2017 Dec; 63(6):444-448. PubMed ID: 29122307
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Correlation of intracranial pressure and diameter of the sheath of the optic nerve by computed tomography in severe traumatic brain injury].
    Turkin AM; Oshorov AV; Pogosbekyan EL; Smirnov AS; Dmitrieva AS
    Zh Vopr Neirokhir Im N N Burdenko; 2017; 81(6):81-88. PubMed ID: 29393290
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Sonographic optic nerve sheath diameter as an estimate of intracranial pressure in adult trauma.
    Strumwasser A; Kwan RO; Yeung L; Miraflor E; Ereso A; Castro-Moure F; Patel A; Sadjadi J; Victorino GP
    J Surg Res; 2011 Oct; 170(2):265-71. PubMed ID: 21550065
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Assessment of intracranial pressure with ultrasonographic retrobulbar optic nerve sheath diameter measurement.
    Liu D; Li Z; Zhang X; Zhao L; Jia J; Sun F; Wang Y; Ma D; Wei W
    BMC Neurol; 2017 Sep; 17(1):188. PubMed ID: 28962603
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Ratio of Optic Nerve Sheath Diameter to Eyeball Transverse Diameter by Ultrasound Can Predict Intracranial Hypertension in Traumatic Brain Injury Patients: A Prospective Study.
    Du J; Deng Y; Li H; Qiao S; Yu M; Xu Q; Wang C
    Neurocrit Care; 2020 Apr; 32(2):478-485. PubMed ID: 31218637
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Monitoring of Intracranial Pressure by CT-Defined Optic Nerve Sheath Diameter.
    Bekerman I; Kimiagar I; Sigal T; Vaiman M
    J Neuroimaging; 2016 May; 26(3):309-14. PubMed ID: 26686547
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The role of sonographic optic nerve sheath diameter measurements in pediatric head trauma.
    Şık N; Ulusoy E; Çitlenbik H; Öztürk A; Er A; Yılmaz D; Duman M
    J Ultrasound; 2022 Dec; 25(4):957-963. PubMed ID: 35396696
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The Effect of Different Optic Nerve Sheath Diameter Measurements Using Ultrasound to Assess Intracranial Pressure in Patients With Acute Brain Injury.
    Tian J; Wu GB; Liu XB; Wang ZY; Guo JY
    J Neuroophthalmol; 2024 Jun; 44(2):201-205. PubMed ID: 37440369
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Correlation between ultrasonographic optic nerve sheath diameter and intracranial pressure].
    Li Z; Zhang XX; Yang HQ; Zhao LP; Jia JP; Sun F; Liu DC
    Zhonghua Yan Ke Za Zhi; 2018 Sep; 54(9):683-687. PubMed ID: 30220184
    [No Abstract]   [Full Text] [Related]  

  • 14. Correlation between optic nerve sheath diameter and Rotterdam computer tomography scoring in pediatric brain injury.
    Kayadibi Y; Ülgen Tekerek N; Yeşilbaş O; Tekerek S; Üre E; Kayadibi T; Tekcan Şanlı DE
    Ulus Travma Acil Cerrahi Derg; 2020 Mar; 26(2):212-221. PubMed ID: 32185780
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Measurement of Optic Nerve Sheath Diameter by Computed Tomography in the Pediatric Population: Normal Values.
    Akturk Y; Simsir BD; Hekimoğlu B
    J Pediatr Ophthalmol Strabismus; 2024; 61(1):38-43. PubMed ID: 37092660
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Accuracy of optic nerve sheath diameter measurement by emergency physicians using bedside ultrasound.
    Hassen GW; Bruck I; Donahue J; Mason B; Sweeney B; Saab W; Weedon J; Patel N; Perry K; Matari H; Jaiswal R; Kalantari H
    J Emerg Med; 2015 Apr; 48(4):450-7. PubMed ID: 25497897
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Correlation of optic nerve sheath diameter with direct measurement of intracranial pressure.
    Kimberly HH; Shah S; Marill K; Noble V
    Acad Emerg Med; 2008 Feb; 15(2):201-4. PubMed ID: 18275454
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Diagnostic and prognostic value of the optic nerve sheath diameter with respect to the intracranial pressure and neurological outcome of patients following hemicraniectomy.
    Gao Y; Li Q; Wu C; Liu S; Zhang M
    BMC Neurol; 2018 Dec; 18(1):199. PubMed ID: 30518315
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Optic nerve sheath diameter measurement: a means of detecting raised ICP in adult traumatic and non-traumatic neurosurgical patients.
    Raffiz M; Abdullah JM
    Am J Emerg Med; 2017 Jan; 35(1):150-153. PubMed ID: 27852525
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The relationship between transorbital ultrasound measurement of the optic nerve sheath diameter (ONSD) and invasively measured ICP in children : Part I: repeatability, observer variability and general analysis.
    Padayachy LC; Padayachy V; Galal U; Gray R; Fieggen AG
    Childs Nerv Syst; 2016 Oct; 32(10):1769-78. PubMed ID: 27659819
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 23.