These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. Depth-encoding using optical photon TOF in a prism-PET detector with tapered crystals. Zeng X; LaBella A; Wang Z; Li Y; Tan W; Goldan AH Med Phys; 2024 Jun; 51(6):4044-4055. PubMed ID: 38682574 [TBL] [Abstract][Full Text] [Related]
3. Sub-2 mm depth of interaction localization in PET detectors with prismatoid light guide arrays and single-ended readout using convolutional neural networks. LaBella A; Cao X; Zeng X; Zhao W; Goldan AH Med Phys; 2021 Mar; 48(3):1019-1025. PubMed ID: 33305482 [TBL] [Abstract][Full Text] [Related]
4. Performance of long rectangular semi-monolithic scintillator PET detectors. Zhang X; Wang X; Ren N; Hu B; Ding B; Kuang Z; Wu S; Sang Z; Hu Z; Du J; Liang D; Liu X; Zheng H; Yang Y Med Phys; 2019 Apr; 46(4):1608-1619. PubMed ID: 30723932 [TBL] [Abstract][Full Text] [Related]
5. Prismatoid light guide array for enhanced gamma ray localization in PET: a Monte Carlo simulation study of scintillation photon transport. LaBella A; Zhao W; Lubinsky R; Goldan AH Phys Med Biol; 2020 Sep; 65(18):18LT01. PubMed ID: 32413872 [TBL] [Abstract][Full Text] [Related]
6. Development of depth encoding small animal PET detectors using dual-ended readout of pixelated scintillator arrays with SiPMs. Kuang Z; Sang Z; Wang X; Fu X; Ren N; Zhang X; Zheng Y; Yang Q; Hu Z; Du J; Liang D; Liu X; Zheng H; Yang Y Med Phys; 2018 Feb; 45(2):613-621. PubMed ID: 29222959 [TBL] [Abstract][Full Text] [Related]
7. Effects of reflector and crystal surface on the performance of a depth-encoding PET detector with dual-ended readout. Ren S; Yang Y; Cherry SR Med Phys; 2014 Jul; 41(7):072503. PubMed ID: 24989406 [TBL] [Abstract][Full Text] [Related]
8. Interleaved signal multiplexing readout in depth encoding Prism-PET detectors. Li Y; LaBella A; Zeng X; Wang Z; Petersen E; Cao X; Zhao W; Goldan AH Med Phys; 2023 Jul; 50(7):4234-4243. PubMed ID: 37191309 [TBL] [Abstract][Full Text] [Related]
9. A thick semi-monolithic scintillator detector for clinical PET scanners. Zhang C; Wang X; Sun M; Kuang Z; Zhang X; Ren N; Wu S; Sang Z; Sun T; Hu Z; Yang Y; Liu Z Phys Med Biol; 2021 Mar; 66(6):065023. PubMed ID: 33709958 [TBL] [Abstract][Full Text] [Related]
10. A prototype PET scanner with DOI-encoding detectors. Yang Y; Wu Y; Qi J; St James S; Du H; Dokhale PA; Shah KS; Farrell R; Cherry SR J Nucl Med; 2008 Jul; 49(7):1132-40. PubMed ID: 18552140 [TBL] [Abstract][Full Text] [Related]
11. Depth-of-interaction positron emission tomography detector with 45° tilted silicon photomultipliers using dual-ended signal readout. Seo M; Park H; Lee S; Ko GB; Lee JS Med Phys; 2023 Jul; 50(7):4112-4121. PubMed ID: 36907664 [TBL] [Abstract][Full Text] [Related]
12. A conformal TOF-DOI Prism-PET prototype scanner for high-resolution quantitative neuroimaging. Zeng X; Wang Z; Tan W; Petersen E; Cao X; LaBella A; Boccia A; Franceschi D; de Leon M; Chiang GC; Qi J; Biegon A; Zhao W; Goldan AH Med Phys; 2023 Jan; ():. PubMed ID: 36651630 [TBL] [Abstract][Full Text] [Related]
13. Performance of a high-resolution depth encoding PET detector using barium sulfate reflector. Kuang Z; Wang X; Li C; Deng X; Feng K; Hu Z; Fu X; Ren N; Zhang X; Zheng Y; Liang D; Liu X; Zheng H; Yang Y Phys Med Biol; 2017 Jul; 62(15):5945-5958. PubMed ID: 28682792 [TBL] [Abstract][Full Text] [Related]
14. High resolution detectors for whole-body PET scanners by using dual-ended readout. Liu Z; Niu M; Kuang Z; Ren N; Wu S; Cong L; Wang X; Sang Z; Williams C; Yang Y EJNMMI Phys; 2022 Apr; 9(1):29. PubMed ID: 35445890 [TBL] [Abstract][Full Text] [Related]
15. Ultra-high-resolution depth-encoding small animal PET detectors: Using GAGG and LYSO crystal arrays. Niu M; Liu Z; Kuang Z; Wang X; Ren N; Sang Z; Wu S; Cong L; Sun T; Hu Z; Yang Y Med Phys; 2022 May; 49(5):3006-3020. PubMed ID: 35301730 [TBL] [Abstract][Full Text] [Related]
16. Development of a novel depth of interaction PET detector using highly multiplexed G-APD cross-strip encoding. Kolb A; Parl C; Mantlik F; Liu CC; Lorenz E; Renker D; Pichler BJ Med Phys; 2014 Aug; 41(8):081916. PubMed ID: 25086547 [TBL] [Abstract][Full Text] [Related]
17. Performance measurements of a depth-encoding PET detector module based on position-sensitive avalanche photodiode read-out. Dokhale PA; Silverman RW; Shah KS; Grazioso R; Farrell R; Glodo J; McClish MA; Entine G; Tran VH; Cherry SR Phys Med Biol; 2004 Sep; 49(18):4293-304. PubMed ID: 15509066 [TBL] [Abstract][Full Text] [Related]
18. A depth encoding PET detector using four-crystals-to-one-SiPM coupling and light-sharing window method. Zhang X; Xie S; Yang J; Weng F; Xu J; Huang Q; Peng Q Med Phys; 2019 Aug; 46(8):3385-3398. PubMed ID: 31107969 [TBL] [Abstract][Full Text] [Related]
19. Performance comparison of dual-ended readout depth-encoding PET detectors based on BGO and LYSO crystals. Du J; Ariño-Estrada G; Bai X; Cherry SR Phys Med Biol; 2020 Nov; 65(23):. PubMed ID: 33086214 [TBL] [Abstract][Full Text] [Related]
20. Effects of system geometry and other physical factors on photon sensitivity of high-resolution positron emission tomography. Habte F; Foudray AM; Olcott PD; Levin CS Phys Med Biol; 2007 Jul; 52(13):3753-72. PubMed ID: 17664575 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]