These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

143 related articles for article (PubMed ID: 32113858)

  • 1. Histomorphological analysis of false positive PI-RADS 4 and 5 lesions.
    Hupe MC; Offermann A; Tharun L; Fürschke A; Frydrychowicz A; Garstka N; Shariat SF; Barkhausen J; Merseburger AS; Kramer MW; Perner S
    Urol Oncol; 2020 Jul; 38(7):636.e7-636.e12. PubMed ID: 32113858
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Is There Still a Need for Repeated Systematic Biopsies in Patients with Previous Negative Biopsies in the Era of Magnetic Resonance Imaging-targeted Biopsies of the Prostate?
    Exterkate L; Wegelin O; Barentsz JO; van der Leest MG; Kummer JA; Vreuls W; de Bruin PC; Bosch JLHR; van Melick HHE; Somford DM
    Eur Urol Oncol; 2020 Apr; 3(2):216-223. PubMed ID: 31239236
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Prostate cancer detection on transrectal ultrasonography-guided random biopsy despite negative real-time magnetic resonance imaging/ultrasonography fusion-guided targeted biopsy: reasons for targeted biopsy failure.
    Cash H; Günzel K; Maxeiner A; Stephan C; Fischer T; Durmus T; Miller K; Asbach P; Haas M; Kempkensteffen C
    BJU Int; 2016 Jul; 118(1):35-43. PubMed ID: 26384851
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Targeted multiparametric magnetic resonance imaging/transrectal ultrasound-guided (mpMRI/TRUS) fusion prostate biopsy versus systematic random prostate biopsy: A comparative real-life study.
    Pham THN; Schulze-Hagen MF; Rahnama'i MS
    Cancer Rep (Hoboken); 2024 Feb; 7(2):e1962. PubMed ID: 38217298
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Association Between Prostate Imaging Reporting and Data System (PI-RADS) Score for the Index Lesion and Multifocal, Clinically Significant Prostate Cancer.
    Stabile A; Dell'Oglio P; De Cobelli F; Esposito A; Gandaglia G; Fossati N; Brembilla G; Cristel G; Cardone G; Deho' F; Losa A; Suardi N; Gaboardi F; Del Maschio A; Montorsi F; Briganti A
    Eur Urol Oncol; 2018 May; 1(1):29-36. PubMed ID: 31100225
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Accuracy of MRI-ultrasound fusion-guided and systematic biopsy of the prostate.
    In de Braekt T; van Rooij SBT; Daniels-Gooszen AW; Scheepens WA; de Jongh R; Bosch SL; Nederend J
    Br J Radiol; 2024 May; 97(1158):1132-1138. PubMed ID: 38627253
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Improved detection of anterior fibromuscular stroma and transition zone prostate cancer using biparametric and multiparametric MRI with MRI-targeted biopsy and MRI-US fusion guidance.
    Radtke JP; Boxler S; Kuru TH; Wolf MB; Alt CD; Popeneciu IV; Steinemann S; Huettenbrink C; Bergstraesser-Gasch C; Klein T; Kesch C; Roethke M; Becker N; Roth W; Schlemmer HP; Hohenfellner M; Hadaschik BA
    Prostate Cancer Prostatic Dis; 2015 Sep; 18(3):288-96. PubMed ID: 26078202
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Performance of Combined Magnetic Resonance Imaging/Ultrasound Fusion-guided and Systematic Biopsy of the Prostate in Biopsy-naïve Patients and Patients with Prior Biopsies.
    Preisser F; Theissen L; Wenzel M; Humke C; Bodelle B; Köllermann J; Kluth L; Banek S; Becker A; Roos F; Chun FK; Mandel P
    Eur Urol Focus; 2021 Jan; 7(1):39-46. PubMed ID: 31296485
    [TBL] [Abstract][Full Text] [Related]  

  • 9. MRI-Ultrasound Fusion Targeted Biopsy of Prostate Imaging Reporting and Data System Version 2 Category 5 Lesions Found False-Positive at Multiparametric Prostate MRI.
    Sheridan AD; Nath SK; Aneja S; Syed JS; Pahade J; Mathur M; Sprenkle P; Weinreb JC; Spektor M
    AJR Am J Roentgenol; 2018 May; 210(5):W218-W225. PubMed ID: 29489409
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Assessment of free-hand transperineal targeted prostate biopsy using multiparametric magnetic resonance imaging-transrectal ultrasound fusion in Chinese men with prior negative biopsy and elevated prostate-specific antigen.
    Lian H; Zhuang J; Wang W; Zhang B; Shi J; Li D; Fu Y; Jiang X; Zhou W; Guo H
    BMC Urol; 2017 Jul; 17(1):52. PubMed ID: 28679370
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Predictive clinical features for negative histopathology of MRI/Ultrasound-fusion-guided prostate biopsy in patients with high likelihood of cancer at prostate MRI: Analysis from a urologic outpatient clinic1.
    Apfelbeck M; Pfitzinger P; Bischoff R; Rath L; Buchner A; Mumm JN; Schlenker B; Stief CG; Chaloupka M; Clevert DA
    Clin Hemorheol Microcirc; 2020; 76(4):503-511. PubMed ID: 33337358
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Central zone lesions on magnetic resonance imaging: Should we be concerned?
    Tan WP; Mazzone A; Shors S; Antoine N; Ekbal S; Khare N; McKiel C; Pessis D; Deane L
    Urol Oncol; 2017 Jan; 35(1):31.e7-31.e12. PubMed ID: 27692837
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison between target magnetic resonance imaging (MRI) in-gantry and cognitively directed transperineal or transrectal-guided prostate biopsies for Prostate Imaging-Reporting and Data System (PI-RADS) 3-5 MRI lesions.
    Yaxley AJ; Yaxley JW; Thangasamy IA; Ballard E; Pokorny MR
    BJU Int; 2017 Nov; 120 Suppl 3():43-50. PubMed ID: 28749035
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Magnetic resonance/ultrasound fusion targeted biopsy of the prostate can be improved by adding systematic biopsy.
    Cauni VM; Stanescu D; Tanase F; Mihai B; Persu C
    Med Ultrason; 2021 Aug; 23(3):277-282. PubMed ID: 34113933
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The addition of a sagittal image fusion improves the prostate cancer detection in a sensor-based MRI /ultrasound fusion guided targeted biopsy.
    Günzel K; Cash H; Buckendahl J; Königbauer M; Asbach P; Haas M; Neymeyer J; Hinz S; Miller K; Kempkensteffen C
    BMC Urol; 2017 Jan; 17(1):7. PubMed ID: 28086856
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Detection of Gleason 6 prostate cancer in patients with clinically significant prostate cancer on multiparametric magnetic resonance imaging.
    Chaloupka M; Bischoff R; Pfitzinger P; Lellig E; Ledderose S; Buchner A; Schlenker B; Stief C; Clevert DA; Apfelbeck M
    Clin Hemorheol Microcirc; 2019; 73(1):105-111. PubMed ID: 31561351
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Multiparametric Magnetic Resonance Imaging (MRI) and MRI-Transrectal Ultrasound Fusion Biopsy for Index Tumor Detection: Correlation with Radical Prostatectomy Specimen.
    Radtke JP; Schwab C; Wolf MB; Freitag MT; Alt CD; Kesch C; Popeneciu IV; Huettenbrink C; Gasch C; Klein T; Bonekamp D; Duensing S; Roth W; Schueler S; Stock C; Schlemmer HP; Roethke M; Hohenfellner M; Hadaschik BA
    Eur Urol; 2016 Nov; 70(5):846-853. PubMed ID: 26810346
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Additional value of magnetic resonance-targeted biopsies to standard transrectal ultrasound-guided biopsies for detection of clinically significant prostate cancer.
    von Below C; Wassberg C; Norberg M; Tolf A; Kullberg J; Ladjevardi S; Häggman M; Bill Axelson A; Ahlström H
    Scand J Urol; 2017 Apr; 51(2):107-113. PubMed ID: 28635568
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Prostate cancer gene 3 (PCA3) is of additional predictive value in patients with PI-RADS grade III (intermediate) lesions in the MR-guided re-biopsy setting for prostate cancer.
    Kaufmann S; Bedke J; Gatidis S; Hennenlotter J; Kramer U; Notohamiprodjo M; Nikolaou K; Stenzl A; Kruck S
    World J Urol; 2016 Apr; 34(4):509-15. PubMed ID: 26267808
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Analysis of histological findings obtained combining US/mp-MRI fusion-guided biopsies with systematic US biopsies: mp-MRI role in prostate cancer detection and false negative.
    Faiella E; Santucci D; Greco F; Frauenfelder G; Giacobbe V; Muto G; Zobel BB; Grasso RF
    Radiol Med; 2018 Feb; 123(2):143-152. PubMed ID: 29019021
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.