These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
174 related articles for article (PubMed ID: 32118088)
1. Phase-contrast x-ray tomography of neuronal tissue at laboratory sources with submicron resolution. Eckermann M; Töpperwien M; Robisch AL; van der Meer F; Stadelmann C; Salditt T J Med Imaging (Bellingham); 2020 Jan; 7(1):013502. PubMed ID: 32118088 [No Abstract] [Full Text] [Related]
2. Nanoscale x-ray holotomography of human brain tissue with phase retrieval based on multienergy recordings. Robisch AL; Eckermann M; Töpperwien M; van der Meer F; Stadelmann C; Salditt T J Med Imaging (Bellingham); 2020 Jan; 7(1):013501. PubMed ID: 32016134 [TBL] [Abstract][Full Text] [Related]
3. Evaluation of carbon nanotube x-ray source array for stationary head computed tomography. Spronk D; Luo Y; Inscoe CR; Lee YZ; Lu J; Zhou O Med Phys; 2021 Mar; 48(3):1089-1099. PubMed ID: 33382470 [TBL] [Abstract][Full Text] [Related]
4. Method for measuring the focal spot size of an x-ray tube using a coded aperture mask and a digital detector. Russo P; Mettivier G Med Phys; 2011 Apr; 38(4):2099-115. PubMed ID: 21626943 [TBL] [Abstract][Full Text] [Related]
5. Modeling and design of a cone-beam CT head scanner using task-based imaging performance optimization. Xu J; Sisniega A; Zbijewski W; Dang H; Stayman JW; Wang X; Foos DH; Aygun N; Koliatsos VE; Siewerdsen JH Phys Med Biol; 2016 Apr; 61(8):3180-207. PubMed ID: 27025783 [TBL] [Abstract][Full Text] [Related]
6. Performance Evaluation of a Differential Phase-contrast Cone-beam (DPC-CBCT) System for Soft Tissue Imaging. Yu Y; Ning R; Cai W Proc SPIE Int Soc Opt Eng; 2011 Mar; 7961():79614X. PubMed ID: 24027607 [TBL] [Abstract][Full Text] [Related]
7. Flat panel detector-based cone beam computed tomography with a circle-plus-two-arcs data acquisition orbit: preliminary phantom study. Ning R; Tang X; Conover D; Yu R Med Phys; 2003 Jul; 30(7):1694-705. PubMed ID: 12906186 [TBL] [Abstract][Full Text] [Related]
8. Accurate technique for complete geometric calibration of cone-beam computed tomography systems. Cho Y; Moseley DJ; Siewerdsen JH; Jaffray DA Med Phys; 2005 Apr; 32(4):968-83. PubMed ID: 15895580 [TBL] [Abstract][Full Text] [Related]
9. First application of liquid-metal-jet sources for small-animal imaging: high-resolution CT and phase-contrast tumor demarcation. Larsson DH; Lundström U; Westermark UK; Arsenian Henriksson M; Burvall A; Hertz HM Med Phys; 2013 Feb; 40(2):021909. PubMed ID: 23387757 [TBL] [Abstract][Full Text] [Related]
10. Effects of ray profile modeling on resolution recovery in clinical CT. Hofmann C; Knaup M; Kachelrieß M Med Phys; 2014 Feb; 41(2):021907. PubMed ID: 24506628 [TBL] [Abstract][Full Text] [Related]
11. Imaging properties of digital magnification radiography. Boyce SJ; Samei E Med Phys; 2006 Apr; 33(4):984-96. PubMed ID: 16696475 [TBL] [Abstract][Full Text] [Related]
12. New CT system architectures for high temporal resolution with applications to improved geometric dose efficiency and cardiac imaging. Besson GM Med Phys; 2015 May; 42(5):2668-78. PubMed ID: 25979065 [TBL] [Abstract][Full Text] [Related]
13. Flat-panel cone-beam computed tomography for image-guided radiation therapy. Jaffray DA; Siewerdsen JH; Wong JW; Martinez AA Int J Radiat Oncol Biol Phys; 2002 Aug; 53(5):1337-49. PubMed ID: 12128137 [TBL] [Abstract][Full Text] [Related]
14. Fiber orientation in a whole mouse heart reconstructed by laboratory phase-contrast micro-CT. Reichardt M; Töpperwien M; Khan A; Alves F; Salditt T J Med Imaging (Bellingham); 2020 Mar; 7(2):023501. PubMed ID: 32206684 [No Abstract] [Full Text] [Related]
15. Three-dimensional virtual histology of human cerebellum by X-ray phase-contrast tomography. Töpperwien M; van der Meer F; Stadelmann C; Salditt T Proc Natl Acad Sci U S A; 2018 Jul; 115(27):6940-6945. PubMed ID: 29915047 [TBL] [Abstract][Full Text] [Related]
16. Quantification of the effect of system and object parameters on edge enhancement in phase-contrast radiography. Donnelly EF; Price RR; Pickens DR Med Phys; 2003 Nov; 30(11):2888-96. PubMed ID: 14655935 [TBL] [Abstract][Full Text] [Related]