These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

221 related articles for article (PubMed ID: 32118791)

  • 41. Circulatory support for long-term treatment of heart failure: experience with an intraventricular continuous flow pump.
    Westaby S; Banning AP; Saito S; Pigott DW; Jin XY; Catarino PA; Robson D; Moorjani N; Kardos A; Poole-Wilson PA; Jarvik R; Frazier OH
    Circulation; 2002 Jun; 105(22):2588-91. PubMed ID: 12045161
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Effects of centrifugal, axial, and pulsatile left ventricular assist device support on end-organ function in heart failure patients.
    Kamdar F; Boyle A; Liao K; Colvin-adams M; Joyce L; John R
    J Heart Lung Transplant; 2009 Apr; 28(4):352-9. PubMed ID: 19332262
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Haemodynamic evaluation of the new pulsatile-flow generation method in vitro.
    Itkin GP; Bychnev AS; Kuleshov AP; Drobyshev AA
    Int J Artif Organs; 2020 Mar; 43(3):157-164. PubMed ID: 31603372
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Left Ventricular Assist Devices: The Adolescence of a Disruptive Technology.
    Pinney SP
    J Card Fail; 2015 Oct; 21(10):824-34. PubMed ID: 26318347
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Trends in HeartMate 3: What we know so far.
    Lanfear AT; Hamandi M; Fan J; DiMaio JM; George TJ
    J Card Surg; 2020 Jan; 35(1):180-187. PubMed ID: 31692113
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Low incidence of gastrointestinal bleeding and pump thrombosis in patients receiving the INCOR LVAD system in the long-term follow-up.
    Iacovoni A; Centofanti P; Attisani M; Verde A; Terzi A; Senni M; Maiani M; Baronetto A; Livi U; Frigerio M; Rinaldi M
    Int J Artif Organs; 2015 Oct; 38(10):542-7. PubMed ID: 26541278
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Left ventricular device as destination therapy: are we there yet?
    Badiwala MV; Rao V
    Curr Opin Cardiol; 2009 Mar; 24(2):184-9. PubMed ID: 19532106
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Development of the Centrifugal Blood Pump for a Hybrid Continuous Flow Pediatric Total Artificial Heart: Model, Make, Measure.
    Fox CS; Palazzolo T; Hirschhorn M; Stevens RM; Rossano J; Day SW; Tchantchaleishvili V; Throckmorton AL
    Front Cardiovasc Med; 2022; 9():886874. PubMed ID: 35990958
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Novel temporary left ventricular assist system with hydrodynamically levitated bearing pump for bridge to decision: initial preclinical assessment in a goat model.
    Kishimoto S; Takewa Y; Tsukiya T; Mizuno T; Date K; Sumikura H; Fujii Y; Ohnuma K; Togo K; Katagiri N; Naito N; Kishimoto Y; Nakamura Y; Nishimura M; Tatsumi E
    J Artif Organs; 2018 Mar; 21(1):23-30. PubMed ID: 28900738
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Two implantable continuous-flow ventricular assist devices in a biventricular configuration: technique and results.
    Eulert-Grehn JJ; Lanmüller P; Schönrath F; Solowjowa N; Müller M; Mulzer J; Kaufmann F; Starck C; Krabatsch T; Falk V; Potapov E
    Interact Cardiovasc Thorac Surg; 2018 Dec; 27(6):938-942. PubMed ID: 30113626
    [TBL] [Abstract][Full Text] [Related]  

  • 51. The Society of Thoracic Surgeons Intermacs 2023 Annual Report: Focus on Magnetically Levitated Devices.
    Jorde UP; Saeed O; Koehl D; Morris AA; Wood KL; Meyer DM; Cantor R; Jacobs JP; Kirklin JK; Pagani FD; Vega JD
    Ann Thorac Surg; 2024 Jan; 117(1):33-44. PubMed ID: 37944655
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Clinical Implications of Respiratory Failure in Patients Receiving Durable Left Ventricular Assist Devices for End-Stage Heart Failure.
    Miller PE; Caraballo C; Ravindra NG; Mezzacappa C; McCullough M; Gruen J; Levin A; Reinhardt S; Ali A; Desai NR; Ahmad T
    Circ Heart Fail; 2019 Nov; 12(11):e006369. PubMed ID: 31707800
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Device Management and Flow Optimization on Left Ventricular Assist Device Support.
    Tchoukina I; Smallfield MC; Shah KB
    Crit Care Clin; 2018 Jul; 34(3):453-463. PubMed ID: 29907276
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Post-approval study of a highly pulsed, low-shear-rate, continuous-flow, left ventricular assist device, EVAHEART: a Japanese multicenter study using J-MACS.
    Saito S; Yamazaki K; Nishinaka T; Ichihara Y; Ono M; Kyo S; Nishimura T; Nakatani T; Toda K; Sawa Y; Tominaga R; Tanoue T; Saiki Y; Matsui Y; Takemura T; Niinami H; Matsumiya G;
    J Heart Lung Transplant; 2014 Jun; 33(6):599-608. PubMed ID: 24746637
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Minimally invasive versus conventional continuous-flow left ventricular assist device implantation for heart failure: a meta-analysis.
    Zhang B; Guo S; Fu Z; Liu Z
    Heart Fail Rev; 2022 Jul; 27(4):1053-1061. PubMed ID: 33811570
    [TBL] [Abstract][Full Text] [Related]  

  • 56. DuraHeart magnetically levitated centrifugal left ventricular assist system for advanced heart failure patients.
    Morshuis M; Schoenbrodt M; Nojiri C; Roefe D; Schulte-Eistrup S; Boergermann J; Gummert JF; Arusoglu L
    Expert Rev Med Devices; 2010 Mar; 7(2):173-83. PubMed ID: 20214423
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Biventricular Support With Intracorporeal, Continuous Flow, Centrifugal Ventricular Assist Devices.
    Arabía FA; Milano CA; Mahr C; McGee EC; Mokadam NA; Rame JE; Moriguchi JD; Ramzy D; Naftel DC; Myers SL; Kirklin JK
    Ann Thorac Surg; 2018 Feb; 105(2):548-555. PubMed ID: 29157741
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Levitronix CentriMag third-generation magnetically levitated continuous flow pump as bridge to solution.
    Loforte A; Montalto A; Ranocchi F; Della Monica PL; Casali G; Lappa A; Contento C; Musumeci F
    ASAIO J; 2011; 57(4):247-53. PubMed ID: 21701270
    [TBL] [Abstract][Full Text] [Related]  

  • 59. DuraHeart™ magnetically levitated left ventricular assist device: Osaka University experience.
    Sakaguchi T; Matsumiya G; Yoshioka D; Miyagawa S; Nishi H; Yoshikawa Y; Fukushima S; Saito S; Ueno T; Sawa Y
    Circ J; 2013; 77(7):1736-41. PubMed ID: 23595087
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Outcomes after implantation of partial-support left ventricular assist devices in inotropic-dependent patients: Do we still need full-support assist devices?
    Sabashnikov A; Popov AF; Bowles CT; Mohite PN; Weymann A; Hards R; Hedger M; Wittwer T; Wippermann J; Wahlers T; Schoendube FA; Simon AR
    J Thorac Cardiovasc Surg; 2014 Sep; 148(3):1115-21; discussion 1021-2. PubMed ID: 25129605
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 12.