These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

225 related articles for article (PubMed ID: 32134134)

  • 1. The feasibility of leadless pacemaker implantation for superelderly patients.
    Tachibana M; Banba K; Matsumoto K; Ohara M
    Pacing Clin Electrophysiol; 2020 Apr; 43(4):374-381. PubMed ID: 32134134
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Morbidity and mortality in patients precluded for transvenous pacemaker implantation: Experience with a leadless pacemaker.
    Garg A; Koneru JN; Fagan DH; Stromberg K; Padala SK; El-Chami MF; Roberts PR; Piccini JP; Cheng A; Ellenbogen KA
    Heart Rhythm; 2020 Dec; 17(12):2056-2063. PubMed ID: 32763431
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Long-term outcomes in leadless Micra transcatheter pacemakers with elevated thresholds at implantation: Results from the Micra Transcatheter Pacing System Global Clinical Trial.
    Piccini JP; Stromberg K; Jackson KP; Laager V; Duray GZ; El-Chami M; Ellis CR; Hummel J; Jones DR; Kowal RC; Narasimhan C; Omar R; Ritter P; Roberts PR; Soejima K; Zhang S; Reynolds D;
    Heart Rhythm; 2017 May; 14(5):685-691. PubMed ID: 28111349
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Contemporaneous Comparison of Outcomes Among Patients Implanted With a Leadless vs Transvenous Single-Chamber Ventricular Pacemaker.
    Piccini JP; El-Chami M; Wherry K; Crossley GH; Kowal RC; Stromberg K; Longacre C; Hinnenthal J; Bockstedt L
    JAMA Cardiol; 2021 Oct; 6(10):1187-1195. PubMed ID: 34319383
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Design and evaluation of the Micra Transcatheter Pacing System for bradyarrhythmia management.
    Wiles BM; Roberts PR
    Future Cardiol; 2019 Jan; 15(1):9-15. PubMed ID: 30516083
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Leadless Pacemaker Implantation in Hemodialysis Patients: Experience With the Micra Transcatheter Pacemaker.
    El-Chami MF; Clementy N; Garweg C; Omar R; Duray GZ; Gornick CC; Leyva F; Sagi V; Piccini JP; Soejima K; Stromberg K; Roberts PR
    JACC Clin Electrophysiol; 2019 Feb; 5(2):162-170. PubMed ID: 30784685
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Safety and feasibility of leadless pacemaker in patients undergoing atrioventricular node ablation for atrial fibrillation.
    Yarlagadda B; Turagam MK; Dar T; Janagam P; Veerapaneni V; Atkins D; Bommana S; Friedman P; Deshmukh AJ; Doshi R; Reddy VY; Dukkipati SR; Natale A; Lakkireddy D
    Heart Rhythm; 2018 Jul; 15(7):994-1000. PubMed ID: 29496606
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Impact of Leadless Pacemaker Therapy on Cardiac and Atrioventricular Valve Function Through 12 Months of Follow-Up.
    Beurskens NEG; Tjong FVY; de Bruin-Bon RHA; Dasselaar KJ; Kuijt WJ; Wilde AAM; Knops RE
    Circ Arrhythm Electrophysiol; 2019 May; 12(5):e007124. PubMed ID: 31060371
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Implantation of a leadless pacemaker in young adults.
    Strik M; Clementy N; Mondoly P; Eschalier R; Ramirez FD; Racine HP; Haïssaguerre M; Ritter P; Ploux S; Bordachar P
    J Cardiovasc Electrophysiol; 2023 Feb; 34(2):412-417. PubMed ID: 36583963
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Safety of leadless pacemaker implantation in the very elderly.
    Pagan E; Gabriels J; Khodak A; Chang D; Beldner S; Epstein LM; Willner J
    Heart Rhythm; 2020 Dec; 17(12):2023-2028. PubMed ID: 32454218
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Leadless pacemaker implantation after explantation of infected conventional pacemaker systems: A viable solution?
    Beurskens NEG; Tjong FVY; Dasselaar KJ; Kuijt WJ; Wilde AAM; Knops RE
    Heart Rhythm; 2019 Jan; 16(1):66-71. PubMed ID: 30129440
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Performance of the Micra cardiac pacemaker in nonagenarians.
    El Amrani A; Campos B; Alonso-Martín C; Guerra-Ramos JM; Rodríguez-Font E; Moreno-Weidmann Z; Alcalde-Rodríguez Ó; Méndez-Zurita FJ; Santaló M; Espinosa-Viamonte H; Viñolas X
    Rev Esp Cardiol (Engl Ed); 2020 Apr; 73(4):307-312. PubMed ID: 31395499
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of safety and feasibility of leadless pacemaker implantation following the removal of an infected pacemaker.
    Zhang J; He L; Xing Q; Zhou X; Li Y; Zhang L; Lu Y; Tuerhong Z; Yang X; Tang B
    Pacing Clin Electrophysiol; 2021 Oct; 44(10):1711-1716. PubMed ID: 34455604
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Retrieval of Long-Term Implanted Leadless Pacemakers: A Single-Center Experience.
    Minami K; Neužil P; Petrů J; Chovanec M; Hubbard C; Hála P; Janotka M; Škoda J; Šedivá L; Reddy VY
    JACC Clin Electrophysiol; 2020 Dec; 6(14):1744-1751. PubMed ID: 33357570
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Atrioventricular synchronous leadless pacing: Micra AV.
    Hrymniak B; Skoczyński P; Biel B; Banasiak W; Jagielski D
    Cardiol J; 2024; 31(1):147-155. PubMed ID: 37246458
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of the safety and efficacy of Nanostim and Micra transcatheter leadless pacemaker (LP) extractions: a multicenter experience.
    Dar T; Akella K; Murtaza G; Sharma S; Afzal MR; Gopinathannair R; Augostini R; Hummel J; Lakkireddy D
    J Interv Card Electrophysiol; 2020 Jan; 57(1):133-140. PubMed ID: 31907831
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Nanostim leadless pacemaker retrieval and simultaneous micra leadless pacemaker replacement: a single-center experience.
    Asirvatham RS; Vaidya VR; Thome TM; Friedman PA; Cha YM
    J Interv Card Electrophysiol; 2020 Jan; 57(1):125-131. PubMed ID: 31728873
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Leadless Cardiac Pacemakers: Current status of a modern approach in pacing.
    Sideris S; Archontakis S; Dilaveris P; Gatzoulis KA; Trachanas K; Sotiropoulos I; Arsenos P; Tousoulis D; Kallikazaros I
    Hellenic J Cardiol; 2017; 58(6):403-410. PubMed ID: 28529181
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison between leadless and transvenous single-chamber pacemaker therapy in a referral centre for lead extraction.
    Zucchelli G; Tolve S; Barletta V; Di Cori A; Parollo M; De Lucia R; Della Tommasina V; Giannotti Santoro M; Viani S; Cellamaro T; Segreti L; Paperini L; Soldati E; Bongiorni MG
    J Interv Card Electrophysiol; 2021 Aug; 61(2):395-404. PubMed ID: 32712901
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Assessment of injury current during leadless pacemaker implantation.
    Breitenstein A; Saguner AM; Gasperetti A; Hofer D; Koepfli P; Regoli F; Steffel J
    Int J Cardiol; 2021 Jan; 323():113-117. PubMed ID: 32916226
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.