These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

169 related articles for article (PubMed ID: 32139550)

  • 1. Substantial and sustained improvement of serrated polyp detection after a simple educational intervention: results from a prospective controlled trial.
    Bleijenberg AGC; van Leerdam ME; Bargeman M; Koornstra JJ; van Herwaarden YJ; Spaander MC; Sanduleanu S; Bastiaansen BAJ; Schoon EJ; van Lelyveld N; Dekker E; IJspeert JEG
    Gut; 2020 Dec; 69(12):2150-2158. PubMed ID: 32139550
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Serrated polyp detection and risk of interval post-colonoscopy colorectal cancer: a population-based study.
    van Toledo DEFWM; IJspeert JEG; Bossuyt PMM; Bleijenberg AGC; van Leerdam ME; van der Vlugt M; Lansdorp-Vogelaar I; Spaander MCW; Dekker E
    Lancet Gastroenterol Hepatol; 2022 Aug; 7(8):747-754. PubMed ID: 35550250
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effect of an E-learning resource on endoscopists' proximal serrated polyp detection rate: a randomized controlled trial.
    van Toledo DEFWM; IJspeert JEG; Bleijenberg AGC; Depla A; Montazeri NSM; Dekker E
    Endoscopy; 2024 Jun; 56(6):412-420. PubMed ID: 38191001
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Impact of differences in adenoma and proximal serrated polyp detection rate on the long-term effectiveness of FIT-based colorectal cancer screening.
    Bronzwaer MES; Greuter MJE; Bleijenberg AGC; IJspeert JEG; Dekker E; Coupé VMH
    BMC Cancer; 2018 Apr; 18(1):465. PubMed ID: 29695244
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Are adenoma and serrated polyp detection rates correlated with endoscopists' sensitivity of optical diagnosis?
    Bronzwaer MES; Vleugels JLA; van Doorn SC; Dijkgraaf MGW; Fockens P; Dekker E;
    Endoscopy; 2020 Sep; 52(9):763-772. PubMed ID: 32349138
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Significant Variation in the Detection Rates of Proximal Serrated Polyps Among Academic Gastroenterologists, Community Gastroenterologists, and Colorectal Surgeons in a Single Tertiary Care Center.
    Mandaliya R; Baig K; Barnhill M; Murugesan V; Som A; Mohammed U; Jhaveri K; Vangimalla SS; Raymond A; Tran J; Hasan L; Lewis JH; Cho W
    Dig Dis Sci; 2019 Sep; 64(9):2614-2621. PubMed ID: 31152331
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Polyp Sizing Poster Improves Polyp Measurement but not Adenoma Detection Rates by Endoscopists in a Large Community Practice.
    Shaukat A; Shamsi N; Menk J; Church TR; Rank J; Colton JB
    Clin Gastroenterol Hepatol; 2019 Sep; 17(10):2034-2041. PubMed ID: 30312788
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The proximal serrated polyp detection rate is an easy-to-measure proxy for the detection rate of clinically relevant serrated polyps.
    IJspeert JE; van Doorn SC; van der Brug YM; Bastiaansen BA; Fockens P; Dekker E
    Gastrointest Endosc; 2015 Nov; 82(5):870-7. PubMed ID: 25935704
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Impact of an Endoscopic Quality Improvement Program Focused on Adenoma Detection on Sessile Serrated Adenoma/Polyp Detection.
    Racho RG; Krishna M; Coe SG; Thomas CS; Crook JE; Diehl NN; Wallace MB
    Dig Dis Sci; 2017 Jun; 62(6):1464-1471. PubMed ID: 28444509
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effects of Training and Feedback on Accuracy of Predicting Rectosigmoid Neoplastic Lesions and Selection of Surveillance Intervals by Endoscopists Performing Optical Diagnosis of Diminutive Polyps.
    Vleugels JLA; Dijkgraaf MGW; Hazewinkel Y; Wanders LK; Fockens P; Dekker E;
    Gastroenterology; 2018 May; 154(6):1682-1693.e1. PubMed ID: 29425923
    [TBL] [Abstract][Full Text] [Related]  

  • 11. PROXIMAL SERRATED POLYP DETECTION RATE: A COMPLEMENTARY QUALITY INDICATOR FOR ADENOMA DETECTION RATE?
    Leite FAV; Rocha LCM; Silva RRR; Vilela EG; Alberti LR; Madureira CM
    Arq Gastroenterol; 2020; 57(4):466-470. PubMed ID: 33331478
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Providing data for serrated polyp detection rate benchmarks: an analysis of the New Hampshire Colonoscopy Registry.
    Anderson JC; Butterly LF; Weiss JE; Robinson CM
    Gastrointest Endosc; 2017 Jun; 85(6):1188-1194. PubMed ID: 28153571
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Adenoma and sessile serrated polyp detection rates: variation by patient sex and colonic segment but not specialty of the endoscopist.
    Sanaka MR; Gohel T; Podugu A; Kiran RP; Thota PN; Lopez R; Church JM; Burke CA
    Dis Colon Rectum; 2014 Sep; 57(9):1113-9. PubMed ID: 25101608
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Differences in proximal serrated polyp detection among endoscopists are associated with variability in withdrawal time.
    de Wijkerslooth TR; Stoop EM; Bossuyt PM; Tytgat KM; Dees J; Mathus-Vliegen EM; Kuipers EJ; Fockens P; van Leerdam ME; Dekker E
    Gastrointest Endosc; 2013 Apr; 77(4):617-23. PubMed ID: 23321338
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effect of optical diagnosis training on recognition and treatment of submucosal invasive colorectal cancer in community hospitals: a prospective multicenter intervention study.
    Meulen LWT; Haasnoot KJC; Vlug MS; Wolfhagen FHJ; Baven-Pronk MAMC; van der Voorn MPJA; Schwartz MP; Vogelaar L; de Vos Tot Nederveen Cappel WH; Seerden TCJ; Hazen WL; Schrauwen RWM; Alvarez-Herrero L; Schreuder RM; van Nunen AB; Stoop E; de Bruin GJ; Bos P; Marsman WA; Kuiper E; de Bièvre M; Alderlieste YA; Roomer R; Groen J; Bigirwamungu-Bargeman M; Siersema PD; Elias SG; Masclee AAM; Moons LMG;
    Endoscopy; 2024 Oct; 56(10):770-779. PubMed ID: 38657659
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Endoscopist factors that influence serrated polyp detection: a multicenter study.
    Crockett SD; Gourevitch RA; Morris M; Carrell DS; Rose S; Shi Z; Greer JB; Schoen RE; Mehrotra A
    Endoscopy; 2018 Oct; 50(10):984-992. PubMed ID: 29689571
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Colonoscopy may be weak link in organised colorectal cancer screening programme with faecal immunochemical test.
    Denis B; Gendre I
    J Med Screen; 2022 Jun; 29(2):84-91. PubMed ID: 34866481
    [TBL] [Abstract][Full Text] [Related]  

  • 18. An endoscopic quality improvement program improves detection of colorectal adenomas.
    Coe SG; Crook JE; Diehl NN; Wallace MB
    Am J Gastroenterol; 2013 Feb; 108(2):219-26; quiz 227. PubMed ID: 23295274
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Simple proxies for detection of clinically significant serrated polyps and data for their benchmarks.
    Park SK; Park SH; Yang HJ; Jung YS; Park JH; Sohn CI; Park DI
    J Gastroenterol Hepatol; 2020 Aug; 35(8):1365-1371. PubMed ID: 31907971
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Nationally Automated Colonoscopy Performance Feedback Increases Polyp Detection: The NED APRIQOT Randomized Controlled Trial.
    Catlow J; Sharp L; Wagnild J; Lu L; Bhardwaj-Gosling R; Ogundimu E; Kasim A; Brookes M; Lee T; McCarthy S; Gray J; Sniehotta F; Valori R; Westwood C; McNally R; Ruwende J; Sinclair S; Deane J; ; Rutter M
    Clin Gastroenterol Hepatol; 2024 Sep; 22(9):1926-1936. PubMed ID: 38759827
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.