These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

144 related articles for article (PubMed ID: 32149243)

  • 1. Electron Inelastic Mean Free Paths for LiF, CaF
    Flores-Mancera MA; Villarrubia JS; Massillon-Jl G
    ACS Omega; 2020 Mar; 5(8):4139-4147. PubMed ID: 32149243
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Calculations of Electron Inelastic Mean Free Paths. XI. Data for Liquid Water for Energies from 50 eV to 30 keV.
    Shinotsuka H; Da B; Tanuma S; Yoshikawa H; Powell CJ; Penn DR
    Surf Interface Anal; 2017 Apr; 49(4):238-252. PubMed ID: 28751796
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Response of LiF:Mg,Ti thermoluminescent dosimeters at photon energies relevant to the dosimetry of brachytherapy (<1 MeV).
    Tedgren AC; Hedman A; Grindborg JE; Carlsson GA
    Med Phys; 2011 Oct; 38(10):5539-50. PubMed ID: 21992372
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Calculations of electron inelastic mean free paths. XII. Data for 42 inorganic compounds over the 50 eV to 200 keV range with the full Penn algorithm.
    Shinotsuka H; Tanuma S; Powell CJ; Penn DR
    Surf Interface Anal; 2018; 51(4):427-457. PubMed ID: 32116395
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Low-energy electron properties: Electron inelastic mean free path, energy loss function and the dielectric function. Recent measurements, applications, and the plasmon-coupling theory.
    Chantler CT; Bourke JD
    Ultramicroscopy; 2019 Jun; 201():38-48. PubMed ID: 30925298
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Calculations of stopping powers and inelastic mean free paths for 20 eV-20 keV electrons in 11 types of human tissue.
    Tan Z; Liu W
    Appl Radiat Isot; 2013 Dec; 82():325-31. PubMed ID: 24144616
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Variation in the calibrated response of LiF, Al2O3, and silicon dosimeters when used for in-phantom measurements of source photons with energies between 30 KeV AND 300 KeV.
    Poudel S; Currier B; Medich DC
    Health Phys; 2015 Apr; 108(4):434-42. PubMed ID: 25706137
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of luminescence detectors of Al
    Ekendahl D; Kurková D; Judas L; Čemusová Z; Reimitz D; Kubínová M; Kapuciánová M; Hupka I
    Appl Radiat Isot; 2021 Dec; 178():109947. PubMed ID: 34536830
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Alternative Approach for the Determination of Mean Free Paths of Electron Scattering in Liquid Water Based on Experimental Data.
    Schild A; Peper M; Perry C; Rattenbacher D; Wörner HJ
    J Phys Chem Lett; 2020 Feb; 11(3):1128-1134. PubMed ID: 31928019
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A new calculation on the stopping power and mean free path for low energy electrons in toluene over energy range of 20-10000 eV.
    Tan Z; Xia Y; Liu X; Zhao M; Zhang L
    Appl Radiat Isot; 2009 Apr; 67(4):625-9. PubMed ID: 19138526
    [TBL] [Abstract][Full Text] [Related]  

  • 11. ENERGY RESPONSE FACTOR of BeO DOSEMETER CHIPS: A MONTE CARLO SIMULATION AND GENERAL CAVITY THEORY STUDY.
    Sarigul N; Surucu M; Aydogan B
    Radiat Prot Dosimetry; 2019 Dec; 185(3):303-309. PubMed ID: 30806472
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Electron inelastic mean free path formula and CSDA-range calculation in biological compounds for low and intermediate energies.
    Akar A; Gümüş H; Okumuşoğlu NT
    Appl Radiat Isot; 2006 May; 64(5):543-50. PubMed ID: 16388951
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Electron stopping power and inelastic mean free path in amino acids and protein over the energy range of 20-20,000 eV.
    Tan Z; Xia Y; Zhao M; Liu X
    Radiat Environ Biophys; 2006 Jul; 45(2):135-43. PubMed ID: 16733724
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Stopping powers and inelastic mean free path of 200eV-50keV electrons in polymer PMMA, PE, and PVC.
    Tahir D; Suarga ; Sari NH; Yulianti
    Appl Radiat Isot; 2015 Jan; 95():59-62. PubMed ID: 25464178
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Dynamic structure factor of diamond and LiF measured using inelastic X-Ray scattering.
    Caliebe WA; Soininen JA; Shirley EL; Kao C; Hamalainen K
    Phys Rev Lett; 2000 Apr; 84(17):3907-10. PubMed ID: 11019236
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The effect of model approximations on single-collision distributions of low-energy electrons in liquid water.
    Emfietzoglou D; Nikjoo H
    Radiat Res; 2005 Jan; 163(1):98-111. PubMed ID: 15606313
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Determining the band gap and mean kinetic energy of atoms from reflection electron energy loss spectra.
    Vos M; Marmitt GG; Finkelstein Y; Moreh R
    J Chem Phys; 2015 Sep; 143(10):104203. PubMed ID: 26374027
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Electron energy loss spectra and overestimation of inelastic mean free paths in many-pole models.
    Bourke JD; Chantler CT
    J Phys Chem A; 2012 Mar; 116(12):3202-5. PubMed ID: 22390614
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Response of TL and OSL passive personal dosimetry systems in poly-energetic and multi-directional photon radiation fields.
    Apostolakopoulos FH; Kržanović N; Stanković K; Perazić L
    Appl Radiat Isot; 2019 Sep; 151():235-241. PubMed ID: 31228731
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Energy response of CaSO4:Dy teflon TLD disk dosimeters to photons and electrons.
    Sharada KS
    Radiat Res; 1983 Jan; 93(1):33-9. PubMed ID: 6823508
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.