137 related articles for article (PubMed ID: 32149695)
1. A High Offset Distribution Tolerance High Resolution ISFET Array With Auto-Compensation for Long-Term Bacterial Metabolism Monitoring.
Duan M; Zhong X; Xu J; Lee YK; Bermak A
IEEE Trans Biomed Circuits Syst; 2020 Jun; 14(3):463-476. PubMed ID: 32149695
[TBL] [Abstract][Full Text] [Related]
2. A robust ISFET pH-measuring front-end for chemical reaction monitoring.
Hu Y; Georgiou P
IEEE Trans Biomed Circuits Syst; 2014 Apr; 8(2):177-85. PubMed ID: 24808415
[TBL] [Abstract][Full Text] [Related]
3. An Ultra-High Frame Rate Ion Imaging Platform Using ISFET Arrays With Real-Time Compression.
Zeng J; Kuang L; Cacho-Soblechero M; Georgiou P
IEEE Trans Biomed Circuits Syst; 2021 Aug; 15(4):820-833. PubMed ID: 34406947
[TBL] [Abstract][Full Text] [Related]
4. A Scalable ISFET Sensing and Memory Array With Sensor Auto-Calibration for On-Chip Real-Time DNA Detection.
Moser N; Rodriguez-Manzano J; Lande TS; Georgiou P
IEEE Trans Biomed Circuits Syst; 2018 Apr; 12(2):390-401. PubMed ID: 29570065
[TBL] [Abstract][Full Text] [Related]
5. An Optical and Temperature Assisted CMOS ISFET Sensor Array for Robust E. Coli Detection.
Duan M; Zhong X; Zhao X; El-Agnaf OM; Lee YK; Bermak A
IEEE Trans Biomed Circuits Syst; 2021 Jun; 15(3):497-508. PubMed ID: 34043514
[TBL] [Abstract][Full Text] [Related]
6. A 128 × 128 Current-Mode Ultra-High Frame Rate ISFET Array With In-Pixel Calibration for Real-Time Ion Imaging.
Zeng J; Kuang L; Miscourides N; Georgiou P
IEEE Trans Biomed Circuits Syst; 2020 Apr; 14(2):359-372. PubMed ID: 32070997
[TBL] [Abstract][Full Text] [Related]
7. A 12.8 k Current-Mode Velocity-Saturation ISFET Array for On-Chip Real-Time DNA Detection.
Miscourides N; Yu LS; Rodriguez-Manzano J; Georgiou P
IEEE Trans Biomed Circuits Syst; 2018 Oct; 12(5):1202-1214. PubMed ID: 30010599
[TBL] [Abstract][Full Text] [Related]
8. A Dual-Sensing Thermo-Chemical ISFET Array for DNA-Based Diagnostics.
Cacho-Soblechero M; Malpartida-Cardenas K; Cicatiello C; Rodriguez-Manzano J; Georgiou P
IEEE Trans Biomed Circuits Syst; 2020 Jun; 14(3):477-489. PubMed ID: 32149696
[TBL] [Abstract][Full Text] [Related]
9. A low power sub- μW chemical gilbert cell for ISFET differential reaction monitoring.
Kalofonou M; Toumazou C
IEEE Trans Biomed Circuits Syst; 2014 Aug; 8(4):565-74. PubMed ID: 24240008
[TBL] [Abstract][Full Text] [Related]
10. A High-Sensitivity Potentiometric 65-nm CMOS ISFET Sensor for Rapid E. coli Screening.
Jiang Y; Liu X; Dang TC; Huang X; Feng H; Zhang Q; Yu H
IEEE Trans Biomed Circuits Syst; 2018 Apr; 12(2):402-415. PubMed ID: 29570066
[TBL] [Abstract][Full Text] [Related]
11. Ultrafast Large-Scale Chemical Sensing With CMOS ISFETs: A Level-Crossing Time-Domain Approach.
Liu Y; Constandinou TG; Georgiou P
IEEE Trans Biomed Circuits Syst; 2019 Dec; 13(6):1201-1213. PubMed ID: 31613781
[TBL] [Abstract][Full Text] [Related]
12. A Dual-Mode Large-Arrayed CMOS ISFET Sensor for Accurate and High-Throughput pH Sensing in Biomedical Diagnosis.
Huang X; Yu H; Liu X; Jiang Y; Yan M; Wu D
IEEE Trans Biomed Eng; 2015 Sep; 62(9):2224-33. PubMed ID: 25850082
[TBL] [Abstract][Full Text] [Related]
13. A LoC Ion Imaging Platform for Spatio-Temporal Characterisation of Ion-Selective Membranes.
Zeng J; Kuang L; Cicatiello C; Sinha A; Moser N; Boutelle M; Georgiou P
IEEE Trans Biomed Circuits Syst; 2022 Aug; 16(4):545-556. PubMed ID: 35763475
[TBL] [Abstract][Full Text] [Related]
14. A Highly Linear CMOS Image Sensor Design Based on an Adaptive Nonlinear Ramp Generator and Fully Differential Pipeline Sampling Quantization with a Double Auto-Zeroing Technique.
Li C; Han B; He J; Guo Z; Wu L
Sensors (Basel); 2020 Feb; 20(4):. PubMed ID: 32075179
[TBL] [Abstract][Full Text] [Related]
15. Sensitivity, Noise and Resolution in a BEOL-Modified Foundry-Made ISFET with Miniaturized Reference Electrode for Wearable Point-of-Care Applications.
Bellando F; Mele LJ; Palestri P; Zhang J; Ionescu AM; Selmi L
Sensors (Basel); 2021 Mar; 21(5):. PubMed ID: 33806584
[TBL] [Abstract][Full Text] [Related]
16. An Integrated Circuit for Chip-Based Analysis of Enzyme Kinetics and Metabolite Quantification.
Cheah BC; Macdonald AI; Martin C; Streklas AJ; Campbell G; Al-Rawhani MA; Nemeth B; Grant JP; Barrett MP; Cumming DR
IEEE Trans Biomed Circuits Syst; 2016 Jun; 10(3):721-30. PubMed ID: 26742138
[TBL] [Abstract][Full Text] [Related]
17. Enhanced biosensing resolution with foundry fabricated individually addressable dual-gated ISFETs.
Duarte-Guevara C; Lai FL; Cheng CW; Reddy B; Salm E; Swaminathan V; Tsui YK; Tuan HC; Kalnitsky A; Liu YS; Bashir R
Anal Chem; 2014 Aug; 86(16):8359-67. PubMed ID: 25072939
[TBL] [Abstract][Full Text] [Related]
18. A Portable Readout System for Biomarker Detection with Aptamer-Modified CMOS ISFET Array.
Ryazantsev D; Shustinskiy M; Sheshil A; Titov A; Grudtsov V; Vechorko V; Kitiashvili I; Puchnin K; Kuznetsov A; Komarova N
Sensors (Basel); 2024 May; 24(10):. PubMed ID: 38793863
[TBL] [Abstract][Full Text] [Related]
19. Label-free CMOS bio sensor with on-chip noise reduction scheme for real-time quantitative monitoring of biomolecules.
Seong-Jin Kim ; Euisik Yoon
IEEE Trans Biomed Circuits Syst; 2012 Jun; 6(3):189-96. PubMed ID: 23853141
[TBL] [Abstract][Full Text] [Related]
20. ISFET pH Sensitivity: Counter-Ions Play a Key Role.
Parizi KB; Xu X; Pal A; Hu X; Wong HS
Sci Rep; 2017 Feb; 7():41305. PubMed ID: 28150700
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]