These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

121 related articles for article (PubMed ID: 32153266)

  • 1. Understanding the mechanical limitations of the performance of soft X-ray monochromators at MAX IV laboratory.
    Sjöblom P; Todorescu G; Urpelainen S
    J Synchrotron Radiat; 2020 Mar; 27(Pt 2):272-283. PubMed ID: 32153266
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A water-cooled monochromator for the B16 Test beamline at the Diamond Light Source: capabilities and performance characterization.
    Dolbnya IP; Sawhney KJS; Scott SM; Dent AJ; Cibin G; Preece GM; Pedersen UK; Kelly J; Murray P
    J Synchrotron Radiat; 2019 Jan; 26(Pt 1):253-262. PubMed ID: 30655493
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Fly-scan-oriented motion analyses and upgraded beamline integration architecture for the High-Dynamic Double-Crystal Monochromator at Sirius/LNLS.
    Geraldes RR; Luiz SAL; de Brito Neto JL; Soares TRS; Dos Reis RD; Calligaris GA; Witvoet G; Vermeulen JPMB
    J Synchrotron Radiat; 2023 Jan; 30(Pt 1):90-110. PubMed ID: 36601930
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Soft X-ray Monochromators for Third-Generation Undulator Sources.
    Padmore HA; Warwick T
    J Synchrotron Radiat; 1994 Oct; 1(Pt 1):27-36. PubMed ID: 16728781
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Performance and characterization of the FinEstBeAMS beamline at the MAX IV Laboratory.
    Chernenko K; Kivimäki A; Pärna R; Wang W; Sankari R; Leandersson M; Tarawneh H; Pankratov V; Kook M; Kukk E; Reisberg L; Urpelainen S; Käämbre T; Siewert F; Gwalt G; Sokolov A; Lemke S; Alimov S; Knedel J; Kutz O; Seliger T; Valden M; Hirsimäki M; Kirm M; Huttula M
    J Synchrotron Radiat; 2021 Sep; 28(Pt 5):1620-1630. PubMed ID: 34475309
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Side-bounce beamlines using single-reflection diamond monochromators at Cornell High Energy Synchrotron Source.
    Stoupin S; Krawczyk T; Sagan D; Temnykh A; Smieska L; Woll A; Ruff J; Lyndaker A; Pauling A; Croom BP; Trigg EB
    J Synchrotron Radiat; 2021 Mar; 28(Pt 2):429-438. PubMed ID: 33650554
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The soft X-ray monochromator at the SASE3 beamline of the European XFEL: from design to operation.
    Gerasimova N; La Civita D; Samoylova L; Vannoni M; Villanueva R; Hickin D; Carley R; Gort R; Van Kuiken BE; Miedema P; Le Guyarder L; Mercadier L; Mercurio G; Schlappa J; Teichman M; Yaroslavtsev A; Sinn H; Scherz A
    J Synchrotron Radiat; 2022 Sep; 29(Pt 5):1299-1308. PubMed ID: 36073890
    [TBL] [Abstract][Full Text] [Related]  

  • 8. On the advantages of operation in second-order diffraction of blazed gratings in soft X-ray monochromators.
    Jark W
    J Synchrotron Radiat; 2019 Sep; 26(Pt 5):1587-1591. PubMed ID: 31490148
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Mechanical design and performance evaluation for plane grating monochromator in a soft X-ray microscopy beamline at SSRF.
    Gong X; Lu Q
    J Xray Sci Technol; 2015; 23(4):409-21. PubMed ID: 26410653
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The SPECIES beamline at the MAX IV Laboratory: a facility for soft X-ray RIXS and APXPS.
    Urpelainen S; Såthe C; Grizolli W; Agåker M; Head AR; Andersson M; Huang SW; Jensen BN; Wallén E; Tarawneh H; Sankari R; Nyholm R; Lindberg M; Sjöblom P; Johansson N; Reinecke BN; Arman MA; Merte LR; Knudsen J; Schnadt J; Andersen JN; Hennies F
    J Synchrotron Radiat; 2017 Jan; 24(Pt 1):344-353. PubMed ID: 28009577
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A five-axis parallel kinematic mirror unit for soft X-ray beamlines at MAX IV.
    Agåker M; Mueller F; Norsk Jensen B; Åhnberg K; Sjöblom P; Deiwiks J; Henniger H; Pärna R; Knudsen J; Thiagarajan B; Såthe C
    J Synchrotron Radiat; 2020 Mar; 27(Pt 2):262-271. PubMed ID: 32153265
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A WISER way for simulating the performance of gratings.
    Manfredda M; Raimondi L; Cocco D
    J Synchrotron Radiat; 2022 Nov; 29(Pt 6):1344-1353. PubMed ID: 36345742
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Design and performance of BOREAS, the beamline for resonant X-ray absorption and scattering experiments at the ALBA synchrotron light source.
    Barla A; Nicolás J; Cocco D; Valvidares SM; Herrero-Martín J; Gargiani P; Moldes J; Ruget C; Pellegrin E; Ferrer S
    J Synchrotron Radiat; 2016 Nov; 23(Pt 6):1507-1517. PubMed ID: 27787258
    [TBL] [Abstract][Full Text] [Related]  

  • 14. High-performance soft x-ray spectromicroscopy beamline at SSRF.
    Xue C; Wang Y; Guo Z; Wu Y; Zhen X; Chen M; Chen J; Xue S; Peng Z; Lu Q; Tai R
    Rev Sci Instrum; 2010 Oct; 81(10):103502. PubMed ID: 21034086
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A laboratory-based hard x-ray monochromator for high-resolution x-ray emission spectroscopy and x-ray absorption near edge structure measurements.
    Seidler GT; Mortensen DR; Remesnik AJ; Pacold JI; Ball NA; Barry N; Styczinski M; Hoidn OR
    Rev Sci Instrum; 2014 Nov; 85(11):113906. PubMed ID: 25430123
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Synchrotron radiation stability with meV-level energy resolution: in situ characterization.
    Si S; Li Z; Xue L; Luo H
    Appl Opt; 2023 Jun; 62(18):4793-4796. PubMed ID: 37707253
    [TBL] [Abstract][Full Text] [Related]  

  • 17. On obtaining high spectral resolution in extreme ultraviolet/soft X-ray monochromators operating off-plane diffraction in a divergent incident beam.
    Jark W
    J Synchrotron Radiat; 2020 Nov; 27(Pt 6):1499-1509. PubMed ID: 33147175
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Beamline simulations using monochromators with high d-spacing crystals.
    Yu XJ; Chi X; Smulders T; Wee ATS; Rusydi A; Sanchez Del Rio M; Breese MBH
    J Synchrotron Radiat; 2022 Sep; 29(Pt 5):1157-1166. PubMed ID: 36073874
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Toward a fully coherent tender and hard X-ray free-electron laser via cascaded EEHG in fourth-generation synchrotron light sources.
    Yang X; Yu LH; Smaluk V; Shaftan T; Huang X
    J Synchrotron Radiat; 2023 Sep; 30(Pt 5):861-875. PubMed ID: 37615636
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Expected thermal deformation and wavefront preservation of a cryogenic Si monochromator for Cornell ERL beamlines.
    Huang R; Bilderback DH; Finkelstein K
    J Synchrotron Radiat; 2014 Mar; 21(Pt 2):366-75. PubMed ID: 24562557
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.