171 related articles for article (PubMed ID: 32156045)
1. Nano/Microscale Thermal Field Distribution: Conducting Thermal Decomposition of Pyrolytic-Type Polymer by Heated AFM Probes.
Li B; Geng Y; Yan Y
Nanomaterials (Basel); 2020 Mar; 10(3):. PubMed ID: 32156045
[TBL] [Abstract][Full Text] [Related]
2. Nanoscale thermal AFM of polymers: transient heat flow effects.
Duvigneau J; Schönherr H; Vancso GJ
ACS Nano; 2010 Nov; 4(11):6932-40. PubMed ID: 20979371
[TBL] [Abstract][Full Text] [Related]
3. Microscopic techniques bridging between nanoscale and microscale with an atomically sharpened tip - field ion microscopy/scanning probe microscopy/ scanning electron microscopy.
Tomitori M; Sasahara A
Microscopy (Oxf); 2014 Nov; 63 Suppl 1():i11-i12. PubMed ID: 25359799
[TBL] [Abstract][Full Text] [Related]
4. Ultrananocrystalline diamond tip integrated onto a heated atomic force microscope cantilever.
Kim HJ; Moldovan N; Felts JR; Somnath S; Dai Z; Jacobs TD; Carpick RW; Carlisle JA; King WP
Nanotechnology; 2012 Dec; 23(49):495302. PubMed ID: 23149947
[TBL] [Abstract][Full Text] [Related]
5. High aspect ratio AFM Probe processing by helium-ion-beam induced deposition.
Onishi K; Guo H; Nagano S; Fujita D
Microscopy (Oxf); 2014 Nov; 63 Suppl 1():i30. PubMed ID: 25359832
[TBL] [Abstract][Full Text] [Related]
6. Nanoscale thermal-mechanical probe determination of 'softening transitions' in thin polymer films.
Zhou J; Berry B; Douglas JF; Karim A; Snyder CR; Soles C
Nanotechnology; 2008 Dec; 19(49):495703. PubMed ID: 21730683
[TBL] [Abstract][Full Text] [Related]
7. Enabling low-noise null-point scanning thermal microscopy by the optimization of scanning thermal microscope probe through a rigorous theory of quantitative measurement.
Hwang G; Chung J; Kwon O
Rev Sci Instrum; 2014 Nov; 85(11):114901. PubMed ID: 25430136
[TBL] [Abstract][Full Text] [Related]
8. Influence of AFM Tip Temperature on THF Hydrate Stability: Theoretical Model and Numerical Simulation.
Peng L; Ning F; Li W; Sun J; Cao P; Liu Z; Xie J
Scanning; 2019; 2019():1694169. PubMed ID: 31741698
[TBL] [Abstract][Full Text] [Related]
9. Selective nano-patterning of graphene using a heated atomic force microscope tip.
Choi YS; Wu X; Lee DW
Rev Sci Instrum; 2014 Apr; 85(4):045002. PubMed ID: 24784648
[TBL] [Abstract][Full Text] [Related]
10. Noncontact sub-10 nm temperature measurement in near-field laser heating.
Yue Y; Chen X; Wang X
ACS Nano; 2011 Jun; 5(6):4466-75. PubMed ID: 21557563
[TBL] [Abstract][Full Text] [Related]
11. Ultra-high vacuum scanning thermal microscopy for nanometer resolution quantitative thermometry.
Kim K; Jeong W; Lee W; Reddy P
ACS Nano; 2012 May; 6(5):4248-57. PubMed ID: 22530657
[TBL] [Abstract][Full Text] [Related]
12. Measuring material softening with nanoscale spatial resolution using heated silicon probes.
Nelson BA; King WP
Rev Sci Instrum; 2007 Feb; 78(2):023702. PubMed ID: 17578112
[TBL] [Abstract][Full Text] [Related]
13. Quantitative temperature distribution measurements by non-contact scanning thermal microscopy using Wollaston probes under ambient conditions.
Zhang Y; Zhu W; Han L; Borca-Tasciuc T
Rev Sci Instrum; 2020 Jan; 91(1):014901. PubMed ID: 32012522
[TBL] [Abstract][Full Text] [Related]
14. A heater-integrated scanning probe microscopy probe array with different tip radii for study of micro-nanosize effects on silicon-tip/polymer-film friction.
Bao H; Li X
Rev Sci Instrum; 2008 Mar; 79(3):033701. PubMed ID: 18377009
[TBL] [Abstract][Full Text] [Related]
15. Quantification of atomic force microscopy tip and sample thermal contact.
Umatova Z; Zhang Y; Rajkumar R; Dobson PS; Weaver JMR
Rev Sci Instrum; 2019 Sep; 90(9):095003. PubMed ID: 31575264
[TBL] [Abstract][Full Text] [Related]
16. Nanometer-scale heat-conductivity measurements on biological samples.
Haeberle W; Pantea M; Hoerber JK
Ultramicroscopy; 2006; 106(8-9):678-86. PubMed ID: 16730408
[TBL] [Abstract][Full Text] [Related]
17. Topography imaging with a heated atomic force microscope cantilever in tapping mode.
Park K; Lee J; Zhang ZM; King WP
Rev Sci Instrum; 2007 Apr; 78(4):043709. PubMed ID: 17477672
[TBL] [Abstract][Full Text] [Related]
18. Electrical discharge in a nanometer-sized air/water gap observed by atomic force microscopy.
Xie XN; Chung HJ; Sow CH; Adamiak K; Wee AT
J Am Chem Soc; 2005 Nov; 127(44):15562-7. PubMed ID: 16262421
[TBL] [Abstract][Full Text] [Related]
19. Nanoscale characterisation and imaging of partially amorphous materials using local thermomechanical analysis and heated tip AFM.
Harding L; King WP; Dai X; Craig DQ; Reading M
Pharm Res; 2007 Nov; 24(11):2048-54. PubMed ID: 17554606
[TBL] [Abstract][Full Text] [Related]
20. Quantification of probe-sample interactions of a scanning thermal microscope using a nanofabricated calibration sample having programmable size.
Ge Y; Zhang Y; Booth JA; Weaver JM; Dobson PS
Nanotechnology; 2016 Aug; 27(32):325503. PubMed ID: 27363896
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]