These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

204 related articles for article (PubMed ID: 32165012)

  • 21. Comparison of retention and stability of two implant-retained overdentures based on implant location.
    Scherer MD; McGlumphy EA; Seghi RR; Campagni WV
    J Prosthet Dent; 2014 Sep; 112(3):515-21. PubMed ID: 24819528
    [TBL] [Abstract][Full Text] [Related]  

  • 22. [Three-dimensional finite element analysis of four-implants supported mandibular overdentures using two different attachments].
    Jiang MY; Wen J; Xu SS; Liu TS; Sun HQ
    Zhonghua Kou Qiang Yi Xue Za Zhi; 2019 Jan; 54(1):41-45. PubMed ID: 30630258
    [No Abstract]   [Full Text] [Related]  

  • 23. Retention characteristics of different attachment systems of mandibular overdentures retained by two or three implants.
    Uludag B; Polat S
    Int J Oral Maxillofac Implants; 2012; 27(6):1509-13. PubMed ID: 23189303
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Patient preference and satisfaction with implant-supported mandibular overdentures retained with ball or locator attachments: a crossover clinical trial.
    Krennmair G; Seemann R; Fazekas A; Ewers R; Piehslinger E
    Int J Oral Maxillofac Implants; 2012; 27(6):1560-8. PubMed ID: 23189311
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Initial retention force of three attachment systems for implant retained-mandibular overdentures: An in vitro study.
    Wakam R; Mawussi KB; Benoit A; Gorin C
    J Prosthodont; 2024 Jun; 33(5):475-483. PubMed ID: 37439403
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Retention loss and wear assessment of three attachment systems for implant retained-mandibular overdentures: An in vitro study.
    Wakam R; Ramalingam S; Mawussi KB; Gorin C; Benoit A
    J Mech Behav Biomed Mater; 2024 Feb; 150():106269. PubMed ID: 38043259
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Influence of different lubricants on the retentive force of LOCATOR(®) attachments - an in vitro pilot study.
    Srinivasan M; Schimmel M; Kobayashi M; Badoud I; Ammann P; Herrmann FR; Müller F
    Clin Oral Implants Res; 2016 Jul; 27(7):771-5. PubMed ID: 26354041
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Retention of Different Attachment Systems for Digitally Designed Mandibular Implant Overdenture.
    Abdelaziz MS; Fawzy AM; Ghali RM; Nassar HI
    J Prosthodont; 2023 Feb; 32(2):162-169. PubMed ID: 35344237
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Freedom of rotation of selected overdenture attachments: an in vitro study.
    Chen IC; Brudvik JS; Mancl LA; Rubenstein JE; Chitswe K; Raigrodski AJ
    J Prosthet Dent; 2011 Aug; 106(2):78-86. PubMed ID: 21821161
    [TBL] [Abstract][Full Text] [Related]  

  • 30. The effect of number and distribution of unsplinted maxillary implants on the load transfer in implant-retained maxillary overdentures: an in vitro study.
    Damghani S; Masri R; Driscoll CF; Romberg E
    J Prosthet Dent; 2012 Jun; 107(6):358-65. PubMed ID: 22633591
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Effect of Different Degrees of Mesial Implant Inclination on the Retention and Stability of Two-Implant Mandibular Overdentures Retained with Stud Attachments: An In Vitro Study.
    ELsyad MA; Abo Hatem OE; Shawky AF; Emera RMK
    Int J Oral Maxillofac Implants; 2018; 33(2):259–268. PubMed ID: 29028850
    [TBL] [Abstract][Full Text] [Related]  

  • 32. In Vitro Evaluation of the Retentive Effectiveness of Axial Attachments Used in Implant-Retained Overdentures After 1 Year of Function.
    Chávarri-Prado D; Brizuela-Velasco A; Diéguez-Pereira M; Chento-Valiente Y; Estrada-Martínez A; Pérez-Pevida E; Álvarez-Arenal Á
    Int J Oral Maxillofac Implants; 2022; 37(3):556-562. PubMed ID: 35727248
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Maximum dislodging forces of implant overdenture stud attachments.
    Petropoulos VC; Smith W
    Int J Oral Maxillofac Implants; 2002; 17(4):526-35. PubMed ID: 12182295
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Maximum dislodging forces of mandibular implant-assisted removable partial dentures: in vitro assessment.
    Gharehchahi J; Asadzadeh N; Mirmortazavi A; Shakeri MT
    J Prosthodont; 2013 Oct; 22(7):543-549. PubMed ID: 23551954
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Mandibular Denture Base Deformation with Locator and Ball Attachments of Implant-Retained Overdentures.
    ELsyad MA; Errabti HM; Mustafa AZ
    J Prosthodont; 2016 Dec; 25(8):656-664. PubMed ID: 26376338
    [TBL] [Abstract][Full Text] [Related]  

  • 36. A comparative study to evaluate microstrain of low-profile attachment associated with and without bar connection in implant assisted mandibular overdenture (in vitro study).
    Ameen NM; El-Khodary NM; Abdel-Hamid AM; Fahmy AE
    BMC Oral Health; 2023 Dec; 23(1):982. PubMed ID: 38066586
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Effects of interimplant distance and cyclic dislodgement on retention of LOCATOR and ball attachments: An in vitro study.
    Salehi R; Shayegh SS; Johnston WM; Hakimaneh SMR
    J Prosthet Dent; 2019 Dec; 122(6):550-556. PubMed ID: 31027962
    [TBL] [Abstract][Full Text] [Related]  

  • 38. In Vitro Effects of Cyclic Dislodgement on Retentive Properties of Various Titanium-Based Dental Implant Overdentures Attachment System.
    Kang TY; Kim JH; Kim KM; Kwon JS
    Materials (Basel); 2019 Nov; 12(22):. PubMed ID: 31744164
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Evaluation of retention and wear of a titanium-formed stud overdenture attachment with different interimplant angulations after simulated clinical use: An in vitro study.
    Elsonbaty MA; Alshimy AM; Abdul-Monem MM; Neena AF
    J Prosthet Dent; 2022 Aug; 128(2):205.e1-205.e10. PubMed ID: 35842280
    [TBL] [Abstract][Full Text] [Related]  

  • 40. The service life of implant-retained overdenture attachment systems.
    Pigozzo MN; Mesquita MF; Henriques GE; Vaz LG
    J Prosthet Dent; 2009 Aug; 102(2):74-80. PubMed ID: 19643220
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 11.