265 related articles for article (PubMed ID: 32174401)
1. Influence of minimal extended firing on dimensional, optical, and mechanical properties of crystalized zirconia-reinforced lithium silicate glass ceramic.
Schweitzer F; Spintzyk S; Geis-Gerstorfer J; Huettig F
J Mech Behav Biomed Mater; 2020 Apr; 104():103644. PubMed ID: 32174401
[TBL] [Abstract][Full Text] [Related]
2. Effect of repeated firing on the topographical, optical, and mechanical properties of fully crystallized lithium silicate-based ceramics.
Al-Johani H; Haider J; Silikas N; Satterthwaite J
J Prosthet Dent; 2024 Apr; 131(4):741.e1-741.e11. PubMed ID: 38242762
[TBL] [Abstract][Full Text] [Related]
3. Lithium disilicate and zirconia reinforced lithium silicate glass-ceramics for CAD/CAM dental restorations: biocompatibility, mechanical and microstructural properties after crystallization.
Mavriqi L; Valente F; Murmura G; Sinjari B; Macrì M; Trubiani O; Caputi S; Traini T
J Dent; 2022 Apr; 119():104054. PubMed ID: 35122936
[TBL] [Abstract][Full Text] [Related]
4. Flexural resistance of Cerec CAD/CAM system ceramic blocks. Part 2: Outsourcing materials.
Sedda M; Vichi A; Del Siena F; Louca C; Ferrari M
Am J Dent; 2014 Feb; 27(1):17-22. PubMed ID: 24902400
[TBL] [Abstract][Full Text] [Related]
5. Strength characterization and lifetime prediction of dental ceramic materials.
Liu C; Eser A; Albrecht T; Stournari V; Felder M; Heintze S; Broeckmann C
Dent Mater; 2021 Jan; 37(1):94-105. PubMed ID: 33208262
[TBL] [Abstract][Full Text] [Related]
6. Impact of crystallization firing process on the microstructure and flexural strength of zirconia-reinforced lithium silicate glass-ceramics.
Riquieri H; Monteiro JB; Viegas DC; Campos TMB; de Melo RM; de Siqueira Ferreira Anzaloni Saavedra G
Dent Mater; 2018 Oct; 34(10):1483-1491. PubMed ID: 29945797
[TBL] [Abstract][Full Text] [Related]
7. Translucency, color stability, and biaxial flexural strength of advanced lithium disilicate ceramic after coffee thermocycling.
Demirel M; Diken Türksayar AA; Donmez MB
J Esthet Restor Dent; 2023 Mar; 35(2):390-396. PubMed ID: 36057856
[TBL] [Abstract][Full Text] [Related]
8. Effect of cement color and tooth-shaded background on the final color of lithium disilicate and zirconia-reinforced lithium silicate ceramics: An in vitro study.
Yildirim B; Recen D; Tekeli Simsek A
J Esthet Restor Dent; 2021 Mar; 33(2):380-386. PubMed ID: 32562352
[TBL] [Abstract][Full Text] [Related]
9. Zirconia-reinforced lithium silicate (ZLS) mechanical and biological properties: A literature review.
Zarone F; Ruggiero G; Leone R; Breschi L; Leuci S; Sorrentino R
J Dent; 2021 Jun; 109():103661. PubMed ID: 33864886
[TBL] [Abstract][Full Text] [Related]
10. The effect of core material, veneering porcelain, and fabrication technique on the biaxial flexural strength and weibull analysis of selected dental ceramics.
Lin WS; Ercoli C; Feng C; Morton D
J Prosthodont; 2012 Jul; 21(5):353-62. PubMed ID: 22462639
[TBL] [Abstract][Full Text] [Related]
11. Color Stability of CAD/CAM Ceramics Prepared with Different Surface Finishing Procedures.
Kanat-Ertürk B
J Prosthodont; 2020 Feb; 29(2):166-172. PubMed ID: 30638286
[TBL] [Abstract][Full Text] [Related]
12. Effect of repeated firing on the translucency of CAD-CAM monolithic glass-ceramics.
Nejatidanesh F; Azadbakht K; Savabi O; Sharifi M; Shirani M
J Prosthet Dent; 2020 Mar; 123(3):530.e1-530.e6. PubMed ID: 31916977
[TBL] [Abstract][Full Text] [Related]
13. Mechanical stability of dental CAD-CAM restoration materials made of monolithic zirconia, lithium disilicate, and lithium disilicate-strengthened aluminosilicate glass-ceramic with and without fatigue conditions.
Al-Haj Husain N; Dürr T; Özcan M; Brägger U; Joda T
J Prosthet Dent; 2022 Jul; 128(1):73-78. PubMed ID: 33546860
[TBL] [Abstract][Full Text] [Related]
14. Impact of Acid Concentration and Firing on the Long-term Bond Strength of a Zirconia-Lithium Silicate Ceramic Following Adhesive Cementation.
Diniz V; Monteiro JB; Rodrigues JVM; Prado PHCO; Melo RM
J Adhes Dent; 2019; 21(4):355-363. PubMed ID: 31432050
[TBL] [Abstract][Full Text] [Related]
15. Effect of thickness, translucency, and firing protocol on the masking ability of a CAD/CAM zirconia-reinforced lithium silicate for different backgrounds.
Passos L; Linke B; Street A; Torrealba Y
Int J Comput Dent; 2019; 22(1):29-38. PubMed ID: 30848252
[TBL] [Abstract][Full Text] [Related]
16. Effect of surface treatments and coffee thermocycling on the color and translucency of CAD-CAM monolithic glass-ceramic.
Alp G; Subasi MG; Johnston WM; Yilmaz B
J Prosthet Dent; 2018 Aug; 120(2):263-268. PubMed ID: 29551378
[TBL] [Abstract][Full Text] [Related]
17. Strength-limiting damage and its mitigation in CAD-CAM zirconia-reinforced lithium-silicate ceramics machined in a fully crystallized state.
Romanyk DL; Guo Y; Rae N; Veldhuis S; Sirovica S; Fleming GJ; Addison O
Dent Mater; 2020 Dec; 36(12):1557-1565. PubMed ID: 33019974
[TBL] [Abstract][Full Text] [Related]
18. Microstructural and Mechanical Characterization of CAD/CAM Materials for Monolithic Dental Restorations.
Furtado de Mendonca A; Shahmoradi M; Gouvêa CVD; De Souza GM; Ellakwa A
J Prosthodont; 2019 Feb; 28(2):e587-e594. PubMed ID: 30121945
[TBL] [Abstract][Full Text] [Related]
19. Effect of Consecutive Firings on the Optical and Mechanical Properties of Silicate and Lithium Disilicate Based Glass-Ceramics.
Campanelli de Morais D; de Oliveira Abu-Izze F; Rivoli Rossi N; Gallo Oliani M; de Assunção E Souza RO; de Siqueira Anzolini Saavedra G; Bottino MA; Marques de Melo Marinho R
J Prosthodont; 2021 Dec; 30(9):776-782. PubMed ID: 33320403
[TBL] [Abstract][Full Text] [Related]
20. Gastric acid challenge of lithium disilicate-reinforced glass-ceramics and zirconia-reinforced lithium silicate glass-ceramic after polishing and glazing-impact on surface properties.
Hjerppe J; Shahramian K; Rosqvist E; Lassila LVJ; Peltonen J; Närhi TO
Clin Oral Investig; 2023 Nov; 27(11):6865-6877. PubMed ID: 37821653
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]