BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

501 related articles for article (PubMed ID: 32174559)

  • 21. Fully Printed Wearable Microfluidic Devices for High-Throughput Sweat Sampling and Multiplexed Electrochemical Analysis.
    Vinoth R; Nakagawa T; Mathiyarasu J; Mohan AMV
    ACS Sens; 2021 Mar; 6(3):1174-1186. PubMed ID: 33517662
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Digital nanoliter to milliliter flow rate sensor with in vivo demonstration for continuous sweat rate measurement.
    Francis J; Stamper I; Heikenfeld J; Gomez EF
    Lab Chip; 2018 Dec; 19(1):178-185. PubMed ID: 30525141
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Antibody-Coated Wearable Organic Electrochemical Transistors for Cortisol Detection in Human Sweat.
    Demuru S; Kim J; El Chazli M; Bruce S; Dupertuis M; Binz PA; Saubade M; Lafaye C; Briand D
    ACS Sens; 2022 Sep; 7(9):2721-2731. PubMed ID: 36054907
    [TBL] [Abstract][Full Text] [Related]  

  • 24. A soft, wearable microfluidic device for the capture, storage, and colorimetric sensing of sweat.
    Koh A; Kang D; Xue Y; Lee S; Pielak RM; Kim J; Hwang T; Min S; Banks A; Bastien P; Manco MC; Wang L; Ammann KR; Jang KI; Won P; Han S; Ghaffari R; Paik U; Slepian MJ; Balooch G; Huang Y; Rogers JA
    Sci Transl Med; 2016 Nov; 8(366):366ra165. PubMed ID: 27881826
    [TBL] [Abstract][Full Text] [Related]  

  • 25. A novel 3D paper-based microfluidic electrochemical glucose biosensor based on rGO-TEPA/PB sensitive film.
    Cao L; Han GC; Xiao H; Chen Z; Fang C
    Anal Chim Acta; 2020 Feb; 1096():34-43. PubMed ID: 31883589
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Development of a microfluidic wearable electrochemical sensor for the non-invasive monitoring of oxidative stress biomarkers in human sweat.
    Ying Z; Qiao L; Liu B; Gao L; Zhang P
    Biosens Bioelectron; 2024 Oct; 261():116502. PubMed ID: 38896980
    [TBL] [Abstract][Full Text] [Related]  

  • 27. A versatile, cost-effective, and flexible wearable biosensor for in situ and ex situ sweat analysis, and personalized nutrition assessment.
    Zhang Z; Azizi M; Lee M; Davidowsky P; Lawrence P; Abbaspourrad A
    Lab Chip; 2019 Oct; 19(20):3448-3460. PubMed ID: 31498355
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Portable biosensor for monitoring cortisol in low-volume perspired human sweat.
    Kinnamon D; Ghanta R; Lin KC; Muthukumar S; Prasad S
    Sci Rep; 2017 Oct; 7(1):13312. PubMed ID: 29042582
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Ultra-Small Wearable Flexible Biosensor for Continuous Sweat Analysis.
    Wang J; Wang L; Li G; Yan D; Liu C; Xu T; Zhang X
    ACS Sens; 2022 Oct; 7(10):3102-3107. PubMed ID: 36218347
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Battery-free, skin-interfaced microfluidic/electronic systems for simultaneous electrochemical, colorimetric, and volumetric analysis of sweat.
    Bandodkar AJ; Gutruf P; Choi J; Lee K; Sekine Y; Reeder JT; Jeang WJ; Aranyosi AJ; Lee SP; Model JB; Ghaffari R; Su CJ; Leshock JP; Ray T; Verrillo A; Thomas K; Krishnamurthi V; Han S; Kim J; Krishnan S; Hang T; Rogers JA
    Sci Adv; 2019 Jan; 5(1):eaav3294. PubMed ID: 30746477
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Battery-free, wireless, and flexible electrochemical patch for in situ analysis of sweat cortisol via near field communication.
    Cheng C; Li X; Xu G; Lu Y; Low SS; Liu G; Zhu L; Li C; Liu Q
    Biosens Bioelectron; 2021 Jan; 172():112782. PubMed ID: 33157409
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Soft, Skin-Interfaced Microfluidic Systems with Passive Galvanic Stopwatches for Precise Chronometric Sampling of Sweat.
    Bandodkar AJ; Choi J; Lee SP; Jeang WJ; Agyare P; Gutruf P; Wang S; Sponenburg RA; Reeder JT; Schon S; Ray TR; Chen S; Mehta S; Ruiz S; Rogers JA
    Adv Mater; 2019 Aug; 31(32):e1902109. PubMed ID: 31206791
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Waterproof, electronics-enabled, epidermal microfluidic devices for sweat collection, biomarker analysis, and thermography in aquatic settings.
    Reeder JT; Choi J; Xue Y; Gutruf P; Hanson J; Liu M; Ray T; Bandodkar AJ; Avila R; Xia W; Krishnan S; Xu S; Barnes K; Pahnke M; Ghaffari R; Huang Y; Rogers JA
    Sci Adv; 2019 Jan; 5(1):eaau6356. PubMed ID: 30746456
    [TBL] [Abstract][Full Text] [Related]  

  • 34. An epidermal wearable microfluidic patch for simultaneous sampling, storage, and analysis of biofluids with counterion monitoring.
    Paul Kunnel B; Demuru S
    Lab Chip; 2022 May; 22(9):1793-1804. PubMed ID: 35316321
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Enzymatic Low Volume Passive Sweat Based Assays for Multi-Biomarker Detection.
    Bhide A; Cheeran S; Muthukumar S; Prasad S
    Biosensors (Basel); 2019 Jan; 9(1):. PubMed ID: 30654428
    [TBL] [Abstract][Full Text] [Related]  

  • 36. A thread/fabric-based band as a flexible and wearable microfluidic device for sweat sensing and monitoring.
    Zhao Z; Li Q; Chen L; Zhao Y; Gong J; Li Z; Zhang J
    Lab Chip; 2021 Mar; 21(5):916-932. PubMed ID: 33438703
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Wearable biosensors for healthcare monitoring.
    Kim J; Campbell AS; de Ávila BE; Wang J
    Nat Biotechnol; 2019 Apr; 37(4):389-406. PubMed ID: 30804534
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Wearable Localized Surface Plasmon Resonance-Based Biosensor with Highly Sensitive and Direct Detection of Cortisol in Human Sweat.
    Nan M; Darmawan BA; Go G; Zheng S; Lee J; Kim S; Lee T; Choi E; Park JO; Bang D
    Biosensors (Basel); 2023 Jan; 13(2):. PubMed ID: 36831950
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Hydrogel-enabled osmotic pumping for microfluidics: towards wearable human-device interfaces.
    Shay T; Dickey MD; Velev OD
    Lab Chip; 2017 Feb; 17(4):710-716. PubMed ID: 28150821
    [TBL] [Abstract][Full Text] [Related]  

  • 40. A wearable patch for continuous monitoring of sweat electrolytes during exertion.
    Alizadeh A; Burns A; Lenigk R; Gettings R; Ashe J; Porter A; McCaul M; Barrett R; Diamond D; White P; Skeath P; Tomczak M
    Lab Chip; 2018 Aug; 18(17):2632-2641. PubMed ID: 30063233
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 26.