These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

196 related articles for article (PubMed ID: 32181172)

  • 1. Freehand Insertion of External Ventricular Drainage Catheter: Evaluation of Accuracy in a Single Center.
    Lee KS; Zhang JJY; Bolem N; Leong ML; Goh CP; Hassan R; Salek AAM; Sein Lwin APT; Teo K; Chou N; Nga V; Yeo TT
    Asian J Neurosurg; 2020; 15(1):45-50. PubMed ID: 32181172
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Orthogonal external ventricular drain (EVD) trajectory from burr holes sited by junior neurosurgical staff is superior to freehand placement: An in-silico model.
    Stuart MJ; Mehigan B; Colbran RE; Withers TK; Ng W
    J Clin Neurosci; 2021 Dec; 94():65-69. PubMed ID: 34863464
    [TBL] [Abstract][Full Text] [Related]  

  • 3. High accuracy of external ventricular drainage placement using anatomical landmarks.
    Brenke C; Fürst J; Katsigiannis S; Carolus AE
    Neurochirurgie; 2020 Dec; 66(6):435-441. PubMed ID: 33080249
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Is Image Guidance Essential for External Ventricular Drain Insertion?
    Fisher B; Soon WC; Ong J; Chan T; Chowdhury Y; Hodson J; White A
    World Neurosurg; 2021 Dec; 156():e329-e337. PubMed ID: 34555577
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Accuracy of freehand external ventricular drain placement in patients after a large decompressive hemicraniectomy.
    Mizrahi CJ; Paldor I; Candanedo C; Mollica S; Itshayek E
    J Clin Neurosci; 2020 Nov; 81():27-31. PubMed ID: 33222928
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Accuracy of external ventricular drainage catheter placement.
    Abdoh MG; Bekaert O; Hodel J; Diarra SM; Le Guerinel C; Nseir R; Bastuji-Garin S; Decq P
    Acta Neurochir (Wien); 2012 Jan; 154(1):153-9. PubMed ID: 21892637
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Accuracy of the freehand pass technique for ventriculostomy catheter placement: retrospective assessment using computed tomography scans.
    Huyette DR; Turnbow BJ; Kaufman C; Vaslow DF; Whiting BB; Oh MY
    J Neurosurg; 2008 Jan; 108(1):88-91. PubMed ID: 18173315
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Accuracy and Safety of Bedside External Ventricular Drain Placement at Two Different Cranial Sites : Kocher's Point versus Forehead.
    Park YG; Woo HJ; Kim E; Park J
    J Korean Neurosurg Soc; 2011 Oct; 50(4):317-21. PubMed ID: 22200013
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Determinants of accuracy of freehand external ventricular drain placement by neurosurgical trainees.
    Pishjoo M; Khatibi K; Etemadrezaie H; Zabihyan S; Ganjeifar B; Safdari M; Baharvahdat H
    Acta Neurochir (Wien); 2021 Apr; 163(4):1113-1119. PubMed ID: 33404870
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Placement of External Ventricular Drain: Comparison of Two Methods.
    Bender M; Schwarm F; Stein M; Uhl E; Reinges MHT
    J Neurol Surg A Cent Eur Neurosurg; 2019 Mar; 80(2):116-121. PubMed ID: 30708390
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Freehand frontal external ventricular drain (EVD) placement: Accuracy and complications.
    Maher Hulou M; Maglinger B; McLouth CJ; Reusche CM; Fraser JF
    J Clin Neurosci; 2022 Mar; 97():7-11. PubMed ID: 35026606
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Safety and accuracy of bedside external ventricular drain placement.
    Kakarla UK; Kim LJ; Chang SW; Theodore N; Spetzler RF
    Neurosurgery; 2008 Jul; 63(1 Suppl 1):ONS162-6; discussion ONS166-7. PubMed ID: 18728595
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Image guidance and improved accuracy of external ventricular drain tip position particularly in patients with small ventricles.
    Shtaya A; Roach J; Sadek AR; Gaastra B; Hempenstall J; Bulters D
    J Neurosurg; 2019 Apr; 130(4):1268-1273. PubMed ID: 29749916
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Utilizing preprocedural CT scans to identify patients at risk for suboptimal external ventricular drain placement with the freehand insertion technique.
    Wilson MP; O'Kelly C; Jack AS; Rempel J
    J Neurosurg; 2019 Jun; 130(6):2048-2054. PubMed ID: 29999445
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Accuracy, Hemorrhagic Complications and CT Radiation Dose of Emergency External Ventricular Drain (EVD) Placement in Pediatric Patients: A 15-Year Retrospective Analysis.
    Stahl R; D'Anastasi M; Forbrig R; Liebig T; Katzendobler S; Weller J; Trumm CG
    Diagnostics (Basel); 2023 Aug; 13(17):. PubMed ID: 37685340
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Factors which influence the complications of external ventricular cerebrospinal fluid drainage.
    Kerry G; Holtmannspoetter M; Kubitz JC; Steiner HH
    Acta Neurochir (Wien); 2022 Feb; 164(2):483-493. PubMed ID: 34626273
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Guided (VENTRI-GUIDE) versus freehand ventriculostomy: study protocol for a randomized controlled trial.
    Sarrafzadeh A; Smoll N; Schaller K
    Trials; 2014 Dec; 15():478. PubMed ID: 25480528
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The importance of aspirin, catheterization accuracy, and catheter design in external ventricular drainage-related hemorrhage: a multicenter study of 1002 procedures.
    Woo PYM; Ng BCF; Xiao JX; Wong D; Seto A; Lam S; Yim C; Lo HY; Po YC; Wong LYW; Lee MWY; Yam KY; Pu JKS; Chan KY; Poon WS
    Acta Neurochir (Wien); 2019 Aug; 161(8):1623-1632. PubMed ID: 31222516
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Factors Predicting Ventriculostomy Revision at a Large Academic Medical Center.
    Ramayya AG; Glauser G; Mcshane B; Branche M; Sinha S; Kvint S; Buch V; Abdullah KG; Kung D; Chen HI; Malhotra NR; Ozturk A
    World Neurosurg; 2019 Mar; 123():e509-e514. PubMed ID: 30503293
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Preliminary Results of Emergency Computed Tomography-Guided Ventricular Drain Placement-Precision for the Most Difficult Cases.
    Nowacki A; Wagner F; Söll N; Hakim A; Beck J; Raabe A; Z'Graggen WJ
    World Neurosurg; 2018 Jun; 114():e1290-e1296. PubMed ID: 29626681
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.