BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

551 related articles for article (PubMed ID: 32197829)

  • 1. Biomechanical comparison of a 3.5 mm anterior locking plate to cannulated screws with anterior tension band wiring in comminuted patellar fractures.
    Wagner FC; Neumann MV; Wolf S; Jonaszik A; Izadpanah K; Piatek S; Südkamp NP
    Injury; 2020 Jun; 51(6):1281-1287. PubMed ID: 32197829
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Biomechanical evaluation of the tension band wiring principle. A comparison between two different techniques for transverse patella fracture fixation.
    Zderic I; Stoffel K; Sommer C; Höntzsch D; Gueorguiev B
    Injury; 2017 Aug; 48(8):1749-1757. PubMed ID: 28622833
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Biomechanical cadaver testing of a fixed-angle plate in comparison to tension wiring and screw fixation in transverse patella fractures.
    Thelen S; Schneppendahl J; Jopen E; Eichler C; Koebke J; Schönau E; Hakimi M; Windolf J; Wild M
    Injury; 2012 Aug; 43(8):1290-5. PubMed ID: 22608600
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Lateral rim variable angle locked plating versus tension band wiring of simple and complex patella fractures: a biomechanical study.
    Warner S; Sommer C; Zderic I; Woodburn W; Castle R; Penman J; Saura-Sanchez E; Helfet DL; Gueorguiev B; Stoffel K
    Arch Orthop Trauma Surg; 2024 May; 144(5):2131-2140. PubMed ID: 38520547
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Cyclic long-term loading of a bilateral fixed-angle plate in comparison with tension band wiring with K-wires or cannulated screws in transverse patella fractures.
    Thelen S; Schneppendahl J; Baumgärtner R; Eichler C; Koebke J; Betsch M; Hakimi M; Windolf J; Wild M
    Knee Surg Sports Traumatol Arthrosc; 2013 Feb; 21(2):311-7. PubMed ID: 22491707
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A Locked Intraosseous Nail for Transverse Patellar Fractures: A Biomechanical Comparison with Tension Band Wiring Through Cannulated Screws.
    Nienhaus M; Zderic I; Wahl D; Gueorguiev B; Rommens PM
    J Bone Joint Surg Am; 2018 Jun; 100(12):e83. PubMed ID: 29916933
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Transverse patella fracture fixation: A cadaveric biomechanical comparison of cannulated screws and anterior tension band versus low-profile, multiplanar mesh plating.
    Garner MR; Homcha B; Cowman T; Goss M; Reid JS; Lewis GS
    Injury; 2024 Jun; 55(6):111574. PubMed ID: 38669892
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Fixation of multifragmentary patella fractures using a bilateral fixed-angle plate.
    Thelen S; Betsch M; Schneppendahl J; Grassmann J; Hakimi M; Eichler C; Windolf J; Wild M
    Orthopedics; 2013 Nov; 36(11):e1437-43. PubMed ID: 24200450
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparison of cannulated screw with tension band wiring versus compressive cannulated locking bolt and nut device (CompresSURE) in patella fractures-a cadaveric biomechanical study.
    Domby B; Henderson E; Nayak A; Erdoğan M; Gutierrez S; Santoni BG; Sagi HC
    J Orthop Trauma; 2012 Dec; 26(12):678-83. PubMed ID: 22932750
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Is There Any Difference Between The Biomechanical Strengths Of The Current Fixation Techniques For Comminuted Distal Patellar Fractures? (Comparison Of Distal Patella Fracture Fixation Techniques).
    Kocadal O; Pepe M; Gunes Z; Aksahin E; Duran S; Aktekin CN
    Acta Orthop Belg; 2017 Dec; 83(4):550-557. PubMed ID: 30423661
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Biomechanical comparison of tension band- and interfragmentary screw fixation with a new implant in transverse patella fractures.
    Dargel J; Gick S; Mader K; Koebke J; Pennig D
    Injury; 2010 Feb; 41(2):156-60. PubMed ID: 19665707
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Cannulated Screw Prominence in Tension Band Wiring of Patella Fractures Increases Fracture Gapping: A Cadaver Study.
    Avery MC; Jo S; Chang A; Ricci WM; McAndrew C; Miller AN; Tang S
    Clin Orthop Relat Res; 2019 May; 477(5):1249-1255. PubMed ID: 30998643
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Biomechanics test of fixation of star-shaped six-part patellar fractures with petal-shaped poly-axial locking plate].
    Meng D; Ouyang Y; Chen H; Zhou J; Xie Z; Lin Y; Lin H; Hou C
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2018 Mar; 32(3):311-315. PubMed ID: 29806280
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Treating patella fractures with a locking patella plate - first clinical results.
    Wurm S; Bühren V; Augat P
    Injury; 2018 Jun; 49 Suppl 1():S51-S55. PubMed ID: 29929694
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A Biomechanical Study of an Alternative Internal Fixation Method for Transverse Patella Fractures.
    Han S; Li D; Zhang P; Yin X; Kou Y; Han N; Fu Z
    Orthopedics; 2018 Sep; 41(5):e643-e648. PubMed ID: 30011055
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Roles of the screw types, proximity and anterior band wiring in the surgical fixation of transverse patellar fractures: a finite element investigation.
    Chen CH; Chen YN; Li CT; Chang CW; Chang CH; Peng YT
    BMC Musculoskelet Disord; 2019 Mar; 20(1):99. PubMed ID: 30832645
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Biomechanical comparison of three tension band wiring techniques for transverse fracture of patella: Kirschner wires, cannulated screws, and ring pins.
    Lee KH; Lee Y; Lee YH; Cho BW; Kim MB; Baek GH
    J Orthop Surg (Hong Kong); 2019; 27(3):2309499019882140. PubMed ID: 31711358
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Anterior variable-angle locked plating versus tension band wiring of simple and complex patella fractures - a biomechanical investigation.
    Stoffel K; Zderic I; Pastor T; Woodburn W; Castle R; Penman J; Saura-Sanchez E; Gueorguiev B; Sommer C
    BMC Musculoskelet Disord; 2023 Apr; 24(1):279. PubMed ID: 37041618
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Patella fracture fixation with a non-locked anterior plating technique: A biomechanical study.
    Elkin DM; Galloway JD; Koury K; Ni JJ; Reilly MC; Adams MR; Sirkin MS
    Injury; 2021 Apr; 52(4):686-691. PubMed ID: 33246644
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparative study of locking neutralization plate construct versus tension band wiring with a cannulated screw for patella fractures: experimental and finite element analysis.
    Kim S; Mungalpara N; Wangikar R; Tarabichi M; Karam J; Bedi A; Koh J; Amirouche F
    J Orthop Surg Res; 2024 Jan; 19(1):77. PubMed ID: 38233950
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 28.