  • 1. Calibration of the LiF - thermoluminescent detectors used for personal dose equivalent Hp(3) assessment.
    Wrzesień M
    Z Med Phys; 2020 Aug; 30(3):222-226. PubMed ID: 32199699
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Calibration of thermoluminescent detectors in Hp(0.07) units by using an X-ray tube and a
    Wrzesień M
    Med Pr; 2019 Dec; 70(6):669-673. PubMed ID: 31597982
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Application of whole-body personal TL dosemeters in mixed field beta-gamma radiation.
    Ciupek K; Aksamit D; Wołoszczuk K
    Radiat Prot Dosimetry; 2014 Nov; 162(1-2):20-3. PubMed ID: 25009188
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Reliability of eye lens dosimetry in workers of a positron emission tomography radiopharmaceutical production facility.
    da Silva TA; Guimarães MC; Meireles LS; Teles LL; Lacerda MA
    Appl Radiat Isot; 2016 Nov; 117():70-73. PubMed ID: 26992331
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Response of LiF:Mg,Ti thermoluminescent dosimeters at photon energies relevant to the dosimetry of brachytherapy (<1 MeV).
    Tedgren AC; Hedman A; Grindborg JE; Carlsson GA
    Med Phys; 2011 Oct; 38(10):5539-50. PubMed ID: 21992372
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Energy dependence of new thermoluminescent detectors in terms of HP(10) values.
    Miljanić S; Knezević Z; Stuhec M; Ranogajec-Komor M; Krpan K; Vekić B
    Radiat Prot Dosimetry; 2003; 106(3):253-6. PubMed ID: 14690327
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The response of lif thermoluminescence dosemeters to photon beams in the energy range from 30 kV x rays to 60Co gamma rays.
    Davis SD; Ross CK; Mobit PN; Van der Zwan L; Chase WJ; Shortt KR
    Radiat Prot Dosimetry; 2003; 106(1):33-43. PubMed ID: 14653324
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Energy response of different types of RADOS personal dosemeters with MTS-N (LiF:Mg,Ti) and MCP-N (LiF:Mg,Cu,P) TL detectors.
    Obryk B; Hranitzky C; Stadtmann H; Budzanowski M; Olko P
    Radiat Prot Dosimetry; 2011 Mar; 144(1-4):211-4. PubMed ID: 21227957
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Dosimetry of densely ionising radiation with three LiF phosphors for space applications.
    Bilski P
    Radiat Prot Dosimetry; 2006; 120(1-4):397-400. PubMed ID: 16731689
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of two extremity dosemeters based on LiF:Mg,Cu,P thin detectors for mixed beta-gamma fields.
    Ginjaume M; Pérez S; Ortega X; Duch MA
    Radiat Prot Dosimetry; 2006; 120(1-4):316-20. PubMed ID: 16644980
    [TBL] [Abstract][Full Text] [Related]  

  • 11. DEVELOPMENT OF AN ALGORITHM TO ESTIMATE EYE LENS DOSE IN TERMS OF OPERATIONAL QUANTITY Hp(3) USING HEAD TLD BADGE.
    Madhumita B; Sneha C; Dipali V; Pradhan SM; Bakshi AK; Datta D; Tripathi SM; Singh SK
    Radiat Prot Dosimetry; 2018 Mar; 178(4):364-373. PubMed ID: 28981726
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Is eye lens dosimetry needed in nuclear medicine?
    Wrzesień M; Królicki L; Albiniak Ł; Olszewski J
    J Radiol Prot; 2018 Jun; 38(2):763-774. PubMed ID: 29667600
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Personal dose equivalent Hp(0.07) of medical personnel occupationally exposed to ionizing radiation during 2001-2011.
    Papierz S; Kacprzyk J; Kamiński Z; Adamowicz M; Zmyślony M
    Med Pr; 2012; 63(6):623-7. PubMed ID: 23394003
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A NEW TL-DOS NEUTRON DOSEMETER FOR MEASUREMENTS OF THE PERSONAL DOSE EQUIVALENT HP(10).
    Heiny M; Busch F; Kröninger K; Theinert R; Walbersloh J
    Radiat Prot Dosimetry; 2020 Jun; 188(1):8-12. PubMed ID: 31702769
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Batch homogeneity of LiF(Mg,Cu,P)-GR200 and LiF(Mg,Cu,P)-MCP-NS TL detectors for use as extremity dosemeters at ENEA personal dosimetry service.
    Mariotti F; Uleri G; Fantuzzi E
    Radiat Prot Dosimetry; 2006; 120(1-4):283-8. PubMed ID: 16702241
    [TBL] [Abstract][Full Text] [Related]  

  • 16. ASSESSMENT OF EYE LENS DOSES IN INTERVENTIONAL RADIOLOGY: A SIMULATION IN LABORATORY CONDITIONS.
    Čemusová Z; Ekendahl D; Judas L
    Radiat Prot Dosimetry; 2016 Sep; 170(1-4):256-60. PubMed ID: 26224737
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Eye lens dosimetry: task 2 within the ORAMED project.
    Gualdrini G; Mariotti F; Wach S; Bilski P; Denoziere M; Daures J; Bordy JM; Ferrari P; Monteventi F; Fantuzzi E
    Radiat Prot Dosimetry; 2011 Mar; 144(1-4):473-7. PubMed ID: 21335629
    [TBL] [Abstract][Full Text] [Related]  

  • 18. 2240 IRRADIATED PERSONAL DOSEMETERS FOR THE IC2014 EURADOS INTERCOMPARISON AT SEIBERSDORF.
    Hranitzky C
    Radiat Prot Dosimetry; 2016 Sep; 170(1-4):27-30. PubMed ID: 26311703
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Using LiF:Mg,Cu,P TLDs to estimate the absorbed dose to water in liquid water around an 192Ir brachytherapy source.
    Lucas PA; Aubineau-Lanièce I; Lourenço V; Vermesse D; Cutarella D
    Med Phys; 2014 Jan; 41(1):011711. PubMed ID: 24387503
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Measurement of personal dose equivalent of X and gamma radiation by ring dosimeter: results of intercomparison measurements].
    Adamowicz M; Papierz S; Kacprzyk J; Kamiński Z; Zmyślony M
    Med Pr; 2013; 64(5):631-7. PubMed ID: 24502126
    [TBL] [Abstract][Full Text] [Related]  