These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

41 related articles for article (PubMed ID: 32206486)

  • 1. Sample transport and/or storage can cause falsely low HbA1c levels in blood cells measured by enzymatic assay.
    Koga M; Okumiya T; Ishibashi M
    Diabetol Int; 2020 Apr; 11(2):155-157. PubMed ID: 32206486
    [TBL] [Abstract][Full Text] [Related]  

  • 2. HbA1c levels measured by enzymatic assay during off-site health checkups are lower than those measured by on-site HPLC assay.
    Koga M; Okuda M; Inada S; Ueda SI; Nakamura Y; Okumiya T; Ishibashi M
    Diabetol Int; 2020 Jan; 11(1):67-71. PubMed ID: 31950005
    [TBL] [Abstract][Full Text] [Related]  

  • 3. HbA1c levels Measured by Enzymatic Assay and Immunoassay during Off-Site Health Checkups Are Both Lower than Those Measured by On-Site HPLC Assay.
    Goya K; Tanaka S; Makio T; Kanno M; Tabuchi Y; Fukuzawa K; Nonoguchi K; Ishibashi M; Koga M
    Kobe J Med Sci; 2021 Mar; 66(5):E170-E174. PubMed ID: 34001684
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A case of variant hemoglobin (Hb Agenogi) with type 2 diabetes mellitus showed high HbA1c levels measured by immunoassay due to enhanced antigenicity.
    Yamane Y; Tsumori M; Ishibashi M; Koga M
    Diabetol Int; 2019 Apr; 10(2):138-142. PubMed ID: 31139532
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Interference and blood sample preparation for a pyruvate enzymatic assay.
    Chuang CK; Wang TJ; Yeung CY; Hsieh WS; Lin DS; Ho SC; Lin SP
    Clin Biochem; 2006 Jan; 39(1):74-7. PubMed ID: 16309664
    [TBL] [Abstract][Full Text] [Related]  

  • 6. In-House Algorithm for Reporting Discrepant HbA1c Result and Troubleshooting a Case of False Low HbA1c.
    Pant V; Shrestha A; Pyakurel D; Gautam K; Pradhan S
    EJIFCC; 2021 Oct; 32(3):377-384. PubMed ID: 34819826
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of a point-of-care analyser for the determination of HbA1c with HPLC method.
    Grant DA; Dunseath GJ; Churm R; Luzio SD
    Pract Lab Med; 2017 Aug; 8():26-29. PubMed ID: 28856223
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Falsely Increased Plasma Lactate Dehydrogenase without Hemolysis Following Transport through Pneumatic Tube System.
    Herman DS; Toro E; Baraban EG; Bagg A; Wang P
    J Appl Lab Med; 2019 Nov; 4(3):433-438. PubMed ID: 31659082
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Short communication: Effects of drying and analytical methods on nitrogen concentrations of feeds, feces, milk, and urine of dairy cows.
    Morris DL; Tebbe AW; Weiss WP; Lee C
    J Dairy Sci; 2019 Jun; 102(6):5212-5218. PubMed ID: 30981480
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Air bubbles and hemolysis of blood samples during transport by pneumatic tube systems.
    Mullins GR; Bruns DE
    Clin Chim Acta; 2017 Oct; 473():9-13. PubMed ID: 28803746
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A diabetic patient in whom Hb Weesp was incidentally detected when her HbA1c level was measured.
    Hatayama T; Umeda F; Yamauchi T; Ideguchi H
    Diabetol Int; 2019 Oct; 10(4):300-302. PubMed ID: 31592030
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Assessment of changes in plasma hemoglobin and potassium levels in red cell units during processing and storage.
    Saini N; Basu S; Kaur R; Kaur J
    Transfus Apher Sci; 2015 Jun; 52(3):319-25. PubMed ID: 25665725
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Influence of different methods for measuring HbA1c on health checkups in a rural town in Hokkaido, Japan.
    Oikawa J; Nakamura K; Ukawa S; Kishi T; Nakamura A; Tamakoshi A
    Diabetol Int; 2016 Dec; 7(4):391-397. PubMed ID: 30603291
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Effects of different frequencies of electroacupuncture on blood glucose level in impaired glucose tolerance patients].
    Meng H; Hao JD; Wang HC; Zhao JY; Zhao CL; Zhai X
    Zhen Ci Yan Jiu; 2011 Jun; 36(3):220-3. PubMed ID: 21793389
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The Effect of Pneumatic Tube Systems on the Hemolysis of Biochemistry Blood Samples.
    Cakirca G; Erdal H
    J Emerg Nurs; 2017 May; 43(3):255-258. PubMed ID: 28359708
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Antioxidant properties of citric acid interfere with the uricase-based measurement of circulating uric acid.
    Ryan EM; Duryee MJ; Hollins A; Dover SK; Pirruccello S; Sayles H; Real KD; Hunter CD; Thiele GM; Mikuls TR
    J Pharm Biomed Anal; 2019 Feb; 164():460-466. PubMed ID: 30447534
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Hemolysis falsely decreases intraoperative parathyroid hormone levels.
    Moalem J; Ruan DT; Farkas RL; Shen WT; Gosnell JE; Miller S; Duh QY; Clark OH; Kebebew E
    Am J Surg; 2009 Feb; 197(2):222-6. PubMed ID: 19095211
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The use of dried blood spot sampling for the measurement of HbA1c: a cross-sectional study.
    Mastronardi CA; Whittle B; Tunningley R; Neeman T; Paz-Filho G
    BMC Clin Pathol; 2015; 15():13. PubMed ID: 26157353
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Smartphone Application Monitoring of Acceleration Forces During Pneumatic Tube System Transport of Emergency Department Patient Samples.
    Heireman L; Stroobants J; Uyttenbroeck W; Goossens Y; Dreezen C; Luyts D; Broeck LVD; Delanghe J; Heylen E; Mahieu B
    Clin Lab; 2018 Jul; 64(7):1297-1304. PubMed ID: 30146841
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Fingerprick blood samples can be used to accurately measure tacrolimus levels by tandem mass spectrometry.
    Webb NJ; Roberts D; Preziosi R; Keevil BG
    Pediatr Transplant; 2005 Dec; 9(6):729-33. PubMed ID: 16269043
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 3.