These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
161 related articles for article (PubMed ID: 32211565)
1. Enhanced physicochemical and biological properties of C/Cu dual ions implanted medical titanium. Xia C; Ma X; Zhang X; Li K; Tan J; Qiao Y; Liu X Bioact Mater; 2020 Jun; 5(2):377-386. PubMed ID: 32211565 [TBL] [Abstract][Full Text] [Related]
2. Synergistic Effects of N/Cu Dual Ions Implantation on Stimulating Antibacterial Ability and Angiogenic Activity of Titanium. Xia C; Cai D; Tan J; Li K; Qiao Y; Liu X ACS Biomater Sci Eng; 2018 Sep; 4(9):3185-3193. PubMed ID: 33435059 [TBL] [Abstract][Full Text] [Related]
3. Implanting a Copper Ion into a TiO Chen H; Zhang J; Yang F; Lin T; Zhang J; Cai X; Zhang P; Tan S ACS Biomater Sci Eng; 2022 Apr; 8(4):1464-1475. PubMed ID: 35302342 [TBL] [Abstract][Full Text] [Related]
4. Surface mechanical properties, corrosion resistance, and cytocompatibility of nitrogen plasma-implanted nickel-titanium alloys: a comparative study with commonly used medical grade materials. Yeung KW; Poon RW; Chu PK; Chung CY; Liu XY; Lu WW; Chan D; Chan SC; Luk KD; Cheung KM J Biomed Mater Res A; 2007 Aug; 82(2):403-14. PubMed ID: 17295246 [TBL] [Abstract][Full Text] [Related]
5. Corrosion resistance, surface mechanical properties, and cytocompatibility of plasma immersion ion implantation-treated nickel-titanium shape memory alloys. Yeung KW; Poon RW; Liu XY; Ho JP; Chung CY; Chu PK; Lu WW; Chan D; Cheung KM J Biomed Mater Res A; 2005 Nov; 75(2):256-67. PubMed ID: 16078209 [TBL] [Abstract][Full Text] [Related]
6. Effect of heat treatment on the bio-corrosion properties and wear resistance of antibacterial Co-29Cr-6Mo-xCu alloys. Li W; Wang X; Liu C; Qin G; Zhang E J Mater Sci Mater Med; 2019 Oct; 30(10):112. PubMed ID: 31583472 [TBL] [Abstract][Full Text] [Related]
7. Dual ions implantation of zirconium and nitrogen into magnesium alloys for enhanced corrosion resistance, antimicrobial activity and biocompatibility. Cheng M; Qiao Y; Wang Q; Qin H; Zhang X; Liu X Colloids Surf B Biointerfaces; 2016 Dec; 148():200-210. PubMed ID: 27603717 [TBL] [Abstract][Full Text] [Related]
8. Biological actions of Cu/Zn coimplanted TiN on Ti-6Al-4V alloy. Li Q; Li L; Zhao M; Dong L; Wu J; Li D Biointerphases; 2019 Oct; 14(5):051008. PubMed ID: 31615215 [TBL] [Abstract][Full Text] [Related]
9. Effect of the existing form of Cu element on the mechanical properties, bio-corrosion and antibacterial properties of Ti-Cu alloys for biomedical application. Zhang E; Wang X; Chen M; Hou B Mater Sci Eng C Mater Biol Appl; 2016 Dec; 69():1210-21. PubMed ID: 27612819 [TBL] [Abstract][Full Text] [Related]
10. Effect of oxygen plasma immersion ion implantation treatment on corrosion resistance and cell adhesion of titanium surface. Yang CH; Wang YT; Tsai WF; Ai CF; Lin MC; Huang HH Clin Oral Implants Res; 2011 Dec; 22(12):1426-32. PubMed ID: 21457349 [TBL] [Abstract][Full Text] [Related]
11. Synergistic effects of dual Zn/Ag ion implantation in osteogenic activity and antibacterial ability of titanium. Jin G; Qin H; Cao H; Qian S; Zhao Y; Peng X; Zhang X; Liu X; Chu PK Biomaterials; 2014 Sep; 35(27):7699-713. PubMed ID: 24947228 [TBL] [Abstract][Full Text] [Related]
12. Multifunctions of dual Zn/Mg ion co-implanted titanium on osteogenesis, angiogenesis and bacteria inhibition for dental implants. Yu Y; Jin G; Xue Y; Wang D; Liu X; Sun J Acta Biomater; 2017 Feb; 49():590-603. PubMed ID: 27915020 [TBL] [Abstract][Full Text] [Related]
13. A surface-engineered multifunctional TiO Lin Z; Wu S; Liu X; Qian S; Chu PK; Zheng Y; Cheung KMC; Zhao Y; Yeung KWK Acta Biomater; 2019 Nov; 99():495-513. PubMed ID: 31518705 [TBL] [Abstract][Full Text] [Related]
14. Microstructure, Wettability, Corrosion Resistance and Antibacterial Property of Cu-MTa Ding Z; Wang Y; Zhou Q; Ding Z; Liu J; He Q; Zhang H Biomolecules; 2019 Dec; 10(1):. PubMed ID: 31906220 [TBL] [Abstract][Full Text] [Related]
15. Carbon plasma immersion ion implantation of nickel-titanium shape memory alloys. Poon RW; Yeung KW; Liu XY; Chu PK; Chung CY; Lu WW; Cheung KM; Chan D Biomaterials; 2005 May; 26(15):2265-72. PubMed ID: 15585228 [TBL] [Abstract][Full Text] [Related]
16. Preliminary study on the corrosion resistance, antibacterial activity and cytotoxicity of selective-laser-melted Ti6Al4V-xCu alloys. Guo S; Lu Y; Wu S; Liu L; He M; Zhao C; Gan Y; Lin J; Luo J; Xu X; Lin J Mater Sci Eng C Mater Biol Appl; 2017 Mar; 72():631-640. PubMed ID: 28024632 [TBL] [Abstract][Full Text] [Related]
17. Effect of annealing temperature on mechanical and antibacterial properties of Cu-bearing titanium alloy and its preliminary study of antibacterial mechanism. Peng C; Zhang S; Sun Z; Ren L; Yang K Mater Sci Eng C Mater Biol Appl; 2018 Dec; 93():495-504. PubMed ID: 30274083 [TBL] [Abstract][Full Text] [Related]
18. Design of a nitrogen-implanted titanium-based superelastic alloy with optimized properties for biomedical applications. Gordin DM; Busardo D; Cimpean A; Vasilescu C; Höche D; Drob SI; Mitran V; Cornen M; Gloriant T Mater Sci Eng C Mater Biol Appl; 2013 Oct; 33(7):4173-82. PubMed ID: 23910330 [TBL] [Abstract][Full Text] [Related]
19. Effect of Cu content on the antibacterial activity of titanium-copper sintered alloys. Liu J; Li F; Liu C; Wang H; Ren B; Yang K; Zhang E Mater Sci Eng C Mater Biol Appl; 2014 Feb; 35():392-400. PubMed ID: 24411393 [TBL] [Abstract][Full Text] [Related]
20. Enhanced Physicochemical and Biological Properties of a Low-Temperature Copperized Layer on Gradient Nanograined Pure Titanium. Qiu J; Pan T; Peng M; Chen M; Xu J; Wang J; Wan Y; Hu J ACS Appl Bio Mater; 2021 Apr; 4(4):3524-3531. PubMed ID: 35014437 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]